For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8.35.210 — Regulations applicable to specific materials

Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 8.35.210

Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/9f01789a-f8ca-4aca-ae18-3d519fe1ed41

8.35.210 Regulations applicable to specific materials.

(a) The information in this section is provided for purposes of ensuring the safe and secure handling of the listed hazardous materials, as well as the protection and safety of emergency response personnel: (1) Radioactive materials; (2) Ozone generating facilities; (3) Extremely toxic gases; (4) Explosives; (5) Ammonia. (b) Regulations applicable to each of the aforementioned materials are discussed in detail in the following subsections: (1) Radioactive Materials. (A) Durable, clearly visible signs of warning of radiation dangers shall be placed at all entrances to areas or rooms where radioactive materials are used or stored. In addition, each container in which radioactive materials are used, stored or transported shall bear a durable, clearly visible, appropriate warning sign. Such signs shall bear the three-bladed radiation symbol. (B) Signs are not required for storage of manufactured articles such as instruments or clock dials or electronic tubes or apparatus of which radioactive materials are a component part, and luminous compounds, when securely packed in strong containers, provided the gamma radiation at any surface of the package is less than 10 milliroentgens in 24 hours. Signs are required for radioactive gases and liquids. (C) When not in use, radioactive materials shall be kept in adequately shielded fire resistant containers of such design that the gamma radiation will not exceed 200 milliroentgens per hour or equivalent at any point of readily accessible surface. (D) All storage, handling, and use must comply with the rules and regulations of the State Department of Health Services office of radiological safety. (2) Ozone Generating Facilities. This subsection shall be effective immediately for all facilities. However, facilities which received an occupancy permit before January 1, 1991, may apply for partial or complete exemption from compliance. The city may approve in writing such exemption, at its discretion, for a period of time not to exceed three calendar years. (A) This chapter applies to generators using corona discharge for ozone production, and to applications in which more than one ultraviolet (UV) generator are connected together. Single ultraviolet (UV) ozone generators for consumer use are exempt. (B) Cabinets for outdoor use must meet National Electrical Manufacturers Association (NEMA) Standard 250 of Type 3R or better. (C) Indoor ozone generators must be in an approved sprinklered cabinet vented to an outside safe area. Any discharge to the atmosphere must meet applicable standards. The city may approve a room to act as the secondary containment cabinet if there are adequate safeguards. (D) The room containing ozone generating equipment is considered to be a hazard area. It shall contain a smoke detector. (i) The room shall be built with one-hour fire rated separations. (ii) One exit must be provided for each 500 square feet of floor space. (iii) There shall be an ozone gas monitoring system which will sound a local alarm, provide a readily visible alarm, and shut down the generator in the event of a leak. It shall alarm to a central emergency control station. (iv) Background ozone levels are not allowed to exceed the TLV as established by the ACGIH. (E) Primary ozone piping shall be stainless steel. (i) Ozone piping will be secondarily contained. (ii) All ozone piping shall be impervious to ozone. (iii) All ozone piping shall have the appropriate pressure rating for its use and have welded connections. (iv) Primary ozone piping does not require secondary containment if the line is operated at negative pressure such that any failure of the pipe would result in ambient air being drawn into the pipe rather than released to the environment. (F) All regulated ozone generating facilities shall be properly labeled and have an automatic shutdown system which is accessible from a central emergency control station and will operate under any of the following conditions: (i) When there is a failure of the ventilation of the cabinet and/or room. The preferred method to monitor for an exhaust failure is by detection of a decrease in the exhaust air flow. (ii) When there is no process demand; i.e., the process is shut down. (iii) When the aqueous phase oxidation reduction potential is in excess of 1,200 millivolts (mv) or the dissolved ozone concentration exceeds two milligrams per liter (mg/L). The measurement is made in the process water as it is exposed to the atmosphere. (iv) When the primary containment system is breached, unless there is an operating system which prevents the unsafe buildup of ozone. (3) Extremely Toxic Gases. This subsection shall be effective immediately for all facilities. However, facilities which have received an occupancy permit before January 1, 1991, may apply for partial or complete exemption from compliance. The city may approve in writing such exemption, at its discretion, for a period of time not to exceed three calendar years. (A) Materials regulated under this subsection: (i) Gases which are listed by EPA as acutely hazardous, gases classified as a Poison A by the United States Department of Transportation, and gases with a TLV of 10 parts per million or less, or equivalent as determined by the city, and are not specifically regulated under other sections of this chapter. (ii) Materials meeting requirements above and in compressed gas cylinders and act as a gas upon release at ambient temperature and pressure. (B) All piping and containment vessels shall be secondarily contained. (i) Secondary containment shall be capable of directing a sudden release into a city-approved discharge abatement system. (ii) Secondary containment shall be continuously monitored with an approved gas monitoring system. (C) An automatic shut-off valve which is of a fail-safe-to-close design shall be provided on the system. It shall activate automatically under each of the following conditions: (i) Gas detection; (ii) Failure of primary power unless there is an automatic battery power carry-over to emergency power; (iii) Seismic activation; (iv) Failure of primary containment; (v) Activation of automatic or manual fire alarm. (D) A flow restricting overfill or flow-limiting device shall be installed except in those cases where the corrosive nature of the gas would preclude the installation and/or safe use. (E) Piping and tubing shall have welded connections throughout unless an exhausted enclosure is provided. Gases which are incompatible with ferrous piping may be installed in approved nonferrous piping with approved connections. (F) Emergency power shall be provided for the following unless the facility demonstrates to the city’s satisfaction that it is not necessary to provide standby emergency power to reduce the risk to the community to an acceptable level: (i) Exhaust ventilation; (ii) Emergency abatement system; (iii) Gas detection systems; (iv) Emergency alarm systems; (v) Temperature control systems; (vi) Automatic shut-off valves. (G) Tanks and cylinders intended for the purpose of dispensing and/or storage shall be provided with excess flow control valves marked with their maximum design flow rate except in those cases where the corrosive nature of the gas would preclude their installation and/or safe use. (H) An approved continuous gas detection system shall be provided to detect the presence of gas at or below the permissible exposure limit. The detection system shall initiate a local alarm and an alarm at a remote location. (I) An approved seismically activated valve shall be provided to automatically shut off regulated materials during significant seismic events. (J) When regulated materials are transported through exit corridors there shall be a local manual alarm station at not more than 150-foot intervals and at each exit doorway throughout the transport route. (K) Regulated gas systems shall be provided with an individually dedicated inert gas purge system. (L) Storage of cylinders shall be within independently ventilated gas cabinets or exhaust enclosures without other occupancy or use. (i) Such exhaust systems shall be designed to abate the accidental release of the total volume of regulated materials that may be contained. (ii) Such exhaust systems shall be capable of diluting, adsorbing, absorbing, neutralizing or burning the entire contents of regulated material that may be stored within the enclosure and can be released within a five-minute period. (M) Gas cabinets shall be compatible with the material to be contained within. (i) They shall be operated at negative pressure in relation to the surrounding area. (ii) They shall be provided with self-closing limited access ports or fire-rated windows for access to equipment controls. (iii) The average velocity of ventilation at the face of access ports or windows shall be not less than 200 feet per minute (fpm) with a minimum of 150 fpm at any point of the access port or window. (iv) They shall be connected to an exhaust system as specified in subsection (b)(3)(L)(ii) of this section. (v) They shall be provided with self-closing doors. (vi) They shall be constructed of not less than 12 gauge steel. (N) Abatement systems or equivalents shall be utilized to process all exhaust ventilation of regulated materials. (i) Abatement systems or equivalents shall reduce the maximum allowable concentration at the point of discharge to one-half IDLH or less. (ii) Abatement systems or equivalents shall be designed to process the maximum worst case release possible. (O) No regulated material may be within 75 feet of any air intake. (4) Explosives. (A) All explosive materials, including binary explosives, must be stored, handled and transported in compliance with all relevant regulations of the Department of the Treasury Federal Bureau of Alcohol, Tobacco, and Firearms. (B) No magazine storage for explosive materials may be located closer to inhabited buildings, railway lines, or public highways than the maximum explosive force capacity of the largest quantity of stored material. (5) Ammonia as a Refrigerant. This subsection shall be effective immediately for all facilities. However, facilities which received an occupancy permit before January 1, 1991, may apply for partial or complete exemption from compliance. The city may approve in writing such exemption, at its discretion, for a period of time not to exceed three calendar years. (A) A facility with more than 1,000 pounds of ammonia must meet the standards or equivalents set forth in subsection (b)(5)(B) of this section as approved by the city. (B) Building structure for all new facilities shall comply with the following: (i) The construction of exterior walls shall be of noncombustible materials. (ii) Engine room shall be constructed of noncombustible materials. (iii) Engine room shall be sprinklered. (iv) For all new facilities, an emergency ventilation system(s) shall be provided, which exhausts to the atmosphere through a water deluge system which can be operated from outside the structure and is easily accessible to emergency responders. (v) Ammonia receiving units shall be located on the outside of the structure and secured from access by unauthorized personnel. (C) Appropriate safety cutoffs and control valves shall be installed in an exterior location easily identified and accessible to emergency responders. (D) All ammonia refrigeration systems shall have approved dual safety relief valves properly installed on all vessels, a remote control system for the king valve, and a remote automatic emergency control for ventilation and compressors easily accessible to emergency responders. (E) All ammonia compressors must be positively identified through casing numbers and/or the manufacturer’s name plate and identification number. (i) All ammonia compressors must be specifically designed for use with ammonia refrigerants and operated within design limitations. (ii) Each ammonia compressor shall have automatically operated internal and external relief valves. (iii) Multiple compressor plants’ common discharge shall have suction stop valve(s), discharge stop valve(s), and discharge check valve(s). (iv) Each compressor shall be equipped with a high pressure and a low pressure cutoff switch, and a low differential oil pressure cutoff switch. (v) No compressor shall be altered, modified, or repaired in such a manner that the integrity of the casing may be impacted unless it has been pressure-recertified by the manufacturer or the insurance underwriter. (vi) All compressors shall be equipped with readily observable gauges to accurately indicate oil suction and discharge pressures. (F) All ammonia vessels and heat exchangers over three cubic feet in internal refrigerant volume capacity shall be positively identified through the manufacturer’s name plate and identification number as required in the most recent edition of ANSI/II AR standards. (i) They shall only be operated within their design limitations. (ii) Each vessel and heat exchanger shall have appropriate valving as required in the most recent edition of ANSI/II AR standards. (iii) If signs of surface corrosion appear, they shall be inspected for soundness by a qualified professional with expertise in the field. (iv) Level indicators shall be installed on each vessel and heat exchanger to accurately reflect the refrigerant level within each unit. They shall be easily read and protected from accidental damage. (G) Single or dual safety relief valves shall be provided on all vessels, heat exchangers, oil pots, oil stills, and elsewhere on refrigeration equipment wherever appropriate. (i) Safety relief valves shall be replaced at regular intervals no greater than five years. (ii) All safety relief valves protecting vessels shall be connected above any liquid level. (iii) There shall be no stop valves located between a safety relief valve and the part(s) of the system that the valve is designed to protect. A dual relief valve and three-way valve manifold is an acceptable arrangement. (iv) Safety relief valves shall be appropriately piped to an approved discharge pipe located above any adjacent structure. (v) No relief valves shall be located in a refrigerated space unless adequate precautions have been taken to prevent the migration of moisture into the valve body and/or the relief vent line. (H) Ammonia piping and accessories shall be installed as required in the most recent edition of ANSI/II AR standards. (i) Refrigerant piping shall be coated with a rust preventative and routinely inspected for corrosion. (ii) Signs of vapor barrier failure shall result in immediate replacement of the insulation and/or vapor barrier. (iii) All ammonia piping shall have appropriate pipe markers to indicate use and flow direction. (iv) All oil pots, oil stills, pumps, and evaporators, regardless of size, shall be fitted with a safety relief valve. (v) All vessels containing liquid ammonia, which can be isolated by valves, shall be protected by safety valves vented either to the atmosphere or to system suction. (vi) Accumulators or interstage coolers shall be equipped with high-level float switches which will sound an alarm when a level point beyond standards is reached and, where practical, shall cause the compressor(s) to shut down automatically when high levels of refrigerant are detected. (vii) There shall be a sign in the engine room displaying: a. Name and address of the installing/servicing contractor; b. Average and maximum allowed quantities of refrigerant in the system; and c. The field test pressures. (viii) There shall be no ammonia cylinders, tank cars, or tank trucks connected to the system unless trained personnel are actually conducting a transfer of ammonia. (ix) Ice formations that endanger refrigerant piping or other components are prohibited. (x) Ammonia leaks of any size are prohibited. In the event of the discovery of a leak, it must be repaired as quickly as possible. In the event an ammonia leak is suspected, it must be immediately investigated and receive appropriate mitigation. (xi) A safety shower and eyewash shall be available within 25 feet of the ammonia engine room. (I) Unrefrigerated containers shall contain sufficient space to prevent them from being completely full of liquid at temperatures below 130 degrees F (54 degrees C). (J) All refrigeration equipment shall be designed and operated to prevent the entrance of any liquid. (K) All liquid ammonia containers shall have a manually operated pressure relief valve which is able to release vapor through an approved diffuser, able to be operated from an external location and easily accessible to emergency responders. (L) All rooms enclosing containers of liquid ammonia shall have adequate ventilation to provide a minimum of 10 complete exchanges of room air with outside air, every hour. (Ord. 1946 § 6, 11-27-90. 1990 Code § 3-12309.) Article IV. Hazardous Materials Management Plan

Prior legislation: Ords. 1632, 1643 and 1686.

Ask a question about Fremont law

Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.