§ 11-720 — CORRIDORS AND HALLWAYS
Fresno Municipal Code (Supp. No. 55, Update 1 (online June 23, 2026): codified through Ordinance No. 2026-019) · Fresno Municipal Code § 11-720
Corpus is an independent public-information project, not the official City of Fresno website. Stable reference: corpuslaw.us/code/de056d01-8c32-4353-af53-9b50f0780905
SEC. 11-720. - CORRIDORS AND HALLWAYS.
All public corridors and public hallways serving the occupants shall comply with all the requirements of C.B.C. Section 1007.6, except as follows: (a) Existing nonconforming fire-resistive walls and ceiling of a corridor constructed of wood lath and plaster which are in good condition may be acceptable as equivalent to the required one-hour fire-resistive construction. (b) Existing doors between the corridor and the living unit that are part of the historic fabric of a qualified historical building may be allowed to remain provided approved smoke gaskets and self-closing and latching devices to prevent smoke penetration are installed on the door, or the existing door shall be replaced with a door conforming to the requirements of C.B.C. Section 1004.3.4.3.2.1. (c) Glazing elements that are part of the historic fabric of a qualified historical building and located in corridors may be allowed to remain provided the fixed transoms, glass doors and other glazed openings are provided with smoke gaskets, and one layer of 518-inch type "X" drywall on the room side or other acceptable fire rated protection.
(Added Ord. 2007-102, § 1, eff. 1-20-08).
Ask a question about Fresno law