For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13.40.310 — Criteria

Code of Ordinances, City of Glendale, California (Code 2026-05-19) · Glendale Code of Ordinances § 13.40.310

Corpus is an independent public-information project, not the official City of Glendale website. Stable reference: corpuslaw.us/code/feece832-a09e-470e-b851-f3309cf63f20

§ 13.40.310: Criteria.

The following criteria are established to govern the discharge of industrial waste to the sanitary sewer. A. Policy. It is the policy of the city to assure that the highest and best use of the sanitary sewer is for the collection, treatment and disposal of domestic wastewater. The use of the sanitary sewer system for industrial wastewater is a privilege which is subject to the requirement of this section. B. Regulations. 1. Discharge Prohibitions. a. Except as expressly allowed in an industrial waste permit, no person shall discharge, permit the discharge, cause the discharge or contribute to the discharge of the following to the sanitary sewer or waters of the state: i. Gasoline, mercury, total identifiable chlorinated hydrocarbons, kerosene, naphtha, benzene, toluene, xylene, ethers, alcohols, ketones, aldehydes, peroxides, chlorates, perchlorates, bromates, carbides, hydrides, solvents, pesticides or jet fuel; ii. Any liquids, solids or gases which by reason of their nature or quantity are flammable, reactive, explosive, corrosive or radioactive, or by interaction with other materials could result in fire, explosion or injury; iii. Any solid or viscous materials which could cause obstruction to the flow or operation of the sanitary sewer; iv. Any toxic pollutants in sufficient quantity to injure or interfere with any wastewater treatment process, including private pretreatment systems, to constitute a hazard or cause injury to human, animal, plant or fish life, or to exceed any limitation set forth in this section; v. Any noxious or malodorous liquids, gases or solids in sufficient quantity either singly or by interaction with other materials to create a public nuisance, hazard to life, or to prevent entry of any person to the sanitary sewer; vi. Any material of sufficient quantity to interfere with any sanitary sewer treatment plant process or to render any product thereof unsuitable for reclamation and reuse; vii. Any material in sufficient quantity to cause the sanitary sewer to be in noncompliance with sludge use or disposal criteria, guidelines or regulations in connection with Section 405 of the Clean Water Act, the Federal Water Pollution Control Act of 1972, 33 U.S.C. 1251, et seq.; the Clean Air Act, 42 U.S.C. 7401, et seq.; the Toxic Substances Control Act, 15 U.S.C. 2601, et seq., or state criteria applicable to the sludge management method being used; viii. Any material which will cause the sanitary sewer to violate its National Pollutant Discharge Elimination System Permit, applicable federal or state statutes, rules or regulations; ix. Any wastewater containing pigment which is not removed in the ordinary sanitary sewer treatment process and which creates a visual contrast with the material appearance of the sanitary sewer discharge observable at the point of sanitary sewer discharge; provided, that in no event shall any wastewater containing pigment be discharged to waters of the state; x. Any wastewater having a heat content in such quantities that the temperature of the wastewater at the introduction into any sanitary sewer treatment plant exceeds forty degrees centigrade (one hundred four degrees Fahrenheit); provided, that in no event shall any wastewater having a temperature in excess of 37.8 degrees centigrade (one hundred degrees Fahrenheit) be discharged to waters of the state; xi. Any pollutants, including oxygen demanding pollutants, released at a flow rate or pollutant concentration which will cause or contribute to interference. "Interference" is defined as a discharge which, alone or in conjunction with a discharge or discharges from other sources, inhibits or disrupts the POTW, its treatment processes or operations or its sludge processes, use or disposal; xii. Any stormwater collected and discharged to the sanitary sewer except as specifically authorized by the fire chief; xiii. Single pass cooling water in excess of two hundred gallons per day discharged to the sanitary sewer. However, the blowdown or bleedoff from cooling towers or other evaporative coolers may be accepted in the sanitary sewer; xiv. Any wastewater which constitutes a hazard or may cause injury to human, animal, plant or fish life may create a public nuisance; xv. Portions of the human or animal anatomy; xvi. Floatable material which is readily removable. b. Except as expressly allowed in an industrial waste permit, no person shall discharge, permit the discharge, cause the discharge or contribute to the discharge to the sanitary sewer, or the waters of the state any material of sufficient quantity which, by interaction with other materials, interferes with the sanitary sewer treatment plant process or renders any product thereof unsuitable for reclamation and reuse, causes the sanitary sewer to be in noncompliance as that term is used with respect to provisions listed in subsection (B)(1)(a)(vii) of this section, or which constitutes a hazard to or which may cause injury to human, animal, plant or fish life. 2. Specific Pollutant Limitations. a. No person shall introduce wastewater to the sanitary sewer that exceeds the following limitations: i. Individual requirements on wastewater characteristics shall be established for each discharge after an evaluation of the proposed discharge. All discharges shall meet the following general requirements: Arsenic | 3 mg/l Cadmium | 15 mg/l Copper | 15 mg/l Cyanide (Total) | 10 mg/l Cyanide (Free) | 2 mg/l Dissolved Sulfides | .1 mg/l Lead | 5 mg/l Nickel | 12 mg/l pH range | 5.5-11 Silver | 5 mg/l Chromium | 10 mg/l Zinc | 25 mg/l Dispersed oil and Grease (Total) | 600 mg/l Floatable oil and Grease | None visible Temperature | 40°C (104°F) Chlorinated Hydrocarbons | Essentially none ii. The above limitations shall not apply where more restrictive limitations are imposed by permit or National Categorical Pretreatment Standards. b. Radioactive Wastes. No person shall discharge radioactive wastes to the sanitary sewer system. c. Infectious Wastes. No person shall discharge infectious waste to the sanitary sewer system. d. Food market refuse, food plant wastes and other organic wastes may not be ground and discharged to the sanitary sewer system. e. Disposable hypodermic needles, syringes and associated articles following their use in hospitals, outpatient clinics, medical and dental offices, etc., may not be ground and discharged to the sanitary sewer system. 3. Septic Tanks, Seepage Pits and Cesspools Connections (Private Sewage Disposal Systems). No commercial or industrial facility shall discharge wastewater to a private sewage disposal system. 4. National Categorical Pretreatment Standards. Upon the promulgation of mandatory National Categorical Pretreatment Standards for any industrial subcategory, the National Categorical Pretreatment Standards, if more restrictive than limitations imposed under this section, shall apply. The fire chief may impose a phased compliance schedule to ensure that affected industries meet the National Categorical Pretreatment Standards. Failure to meet the phased compliance schedule may result in permit revocation. Those dischargers subject to National Categorical Pretreatment Standards shall comply with all reporting requirements in accordance with the General Pretreatment Regulations for Existing and New Sources of Pollution (Title 40, Code of Federal Regulations, Part 403), and as subsequently amended. 5. Dilution. No discharger shall use any water to dilute any pollutant to achieve compliance with the discharge limitations contained in this section. 6. Containment of Uncontrolled Discharges. Upon written notification by the fire chief, dischargers shall provide spill containment for uncontrolled discharges of prohibited material or other substances regulated by this section. Facilities to contain spills shall be provided and maintained at the discharger's own cost and expense. Dischargers so notified shall provide detailed spill containment plans, including, facilities and operating procedures to the fire chief for review. Such plans shall be in accordance with Article 80, Section 8003.1.7.4 of the 1994 Uniform Fire Code, and as subsequently amended, and approved by the fire chief before beginning construction. Construction shall be completed within the time period designated by the fire chief. Review and approval of spill containment plans and operating procedures shall not relieve the discharger from the responsibility to modify its facility as necessary to meet the requirements of this section. 7. Notification of Uncontrolled Discharges. a. In the event of an uncontrolled discharge, the discharger shall immediately notify the fire department of the incident by telephone. The notification shall include location of discharge, type of material, concentration and volume and corrective actions taken. b. Within ten days following the uncontrolled discharge, the discharger shall submit to the fire chief a detailed written report describing the cause of the discharge, corrective action taken, and measures to be taken to prevent future occurrences. Such notification shall not relieve the discharger of liability or fines incurred as a result of this uncontrolled discharge. 8. Notice to Employees—Notification to Fire Department of Uncontrolled Discharge. A legible, understandable and conspicuously placed notice shall be permanently posted on the discharger's bulletin board or other prominent place advising employees to call the fire department in the event of an uncontrolled discharge, as soon as possible or within one hour of the discharge, whichever is sooner, and to provide at least the information listed below. In the event a substantial number of the discharger's employees use a language other than English as a primary language, the notice shall be worded in both English and the language or languages involved. The notice shall identify the following as the minimum necessary information which is to be provided to the fire chief: a. Time, location, type, concentration and volume of the discharge; b. Corrective Action Taken. Employers shall ensure that all employees in a position to cause or allow an uncontrolled discharge to occur are advised of this notification procedure.

( Prior code § 25-28 ; Ord. 5105 § 1, 1996 ; Ord. 5268 § 2, 2001 )

Ask a question about Glendale law

Corpus searches the Glendale sections it holds and shows the ones that match, with their citations. Free, no sign-in.