For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30.16.050 — TOD district site planning

Code of Ordinances, City of Glendale, California (Code 2026-05-19) · Glendale Code of Ordinances § 30.16.050

Corpus is an independent public-information project, not the official City of Glendale website. Stable reference: corpuslaw.us/code/b7906886-2542-4409-85c8-6792ed4b4989

§ 30.16.050: TOD district site planning.

A. Site Planning: Public Realm Standards. The public realm consists generally of the publicly owned street rights-of-way and other publicly accessible open spaces such as parks, squares, plazas, paseos, courtyards, and alleys. The public realm defines the visual character and function of an area through a framework of public street rights-of-way that provide circulation, access, and open space. 1. Public realm setback. All new development, or any addition over greater than 10,000 square feet to an existing building, in the TOD district shall comply the following minimum ground floor setbacks measured from the face-of-curb, excluding curb extensions and bio-retentions, to the build-to line on public streets. The build-to line is defined as a line parallel to the street at which the vertical plane of the front building elevation may be located. No building elevation shall be located closer than the build-to line as specified in Figure 30.16.050-A. a. A public realm easement is required on private property if the distance between the existing face-of-curb and the property line is less than 15 feet for sites fronting Los Feliz Road, San Fernando Road, Central Avenue and Brand Boulevard, and 12 feet for sites fronting all other streets in the TOD district. A public realm easement is not required if the distance between the existing face-of-curb and the property line is 15 feet or 12 feet, or greater, respectively. b. Existing or proposed curb extensions shall not be included in the measurement used to determine the required public realm setback. c. Habitable building projections (balconies, etc.) shall not extend over the required public realm. 2. Public realm zones. The intent of the Tropico TOD public realm is to generate a pedestrian-oriented street network that supports and enhances access to transit and consists of three distinct and contiguous zones. a. Parkway zone. Where a public realm setback is required, there shall be a parkway zone width measured from the face-of-curb to the sidewalk zone of five feet for public realm setbacks of 15 feet and four feet for public realm setbacks of 12 feet, as specified in Figures 30.16.050-A. Existing parkway zones greater than five feet or four feet, respectively, must be maintained. i. Street trees (minimum 24-inch box shade trees) shall be installed in the parkway at a maximum of 25 feet on center, per the city's arborist's specification, or at a spacing determined per the city arborist's specifications for the species being planted. Existing street trees shall be maintained unless removal is required by the city. ii. All parkway zones shall be landscaped a minimum of 20 percent, except for driveways and corner intersections. Tree grates may be included up to 50 percent of the required landscaping for parkway zones. iii. Street furniture, landscaping, street trees, bike parking, light and utility poles, utility boxes, traffic control devices, benches, and trash cans are permitted in the parkway zone. iv. The property owner shall maintain the street trees and landscaping in the parkway zone in an orderly and healthy condition, free of weeds and debris. b. Sidewalk zone. Where a public realm setback is required, there shall be a minimum six-foot sidewalk zone width measured from the parkway zone to the building adjacent zone, as specified in Figures 30.16.050-A. i. The required public realm width shall remain clear of all obstructions to maintain universal access. ii. Seating, poles, temporary or permanent signs, bike racks, bicycle sharing facilities, benches, permanent or temporary seating, temporary or permanent fences or enclosures, utility boxes, landscaping, planters, pots, or steps are prohibited in the sidewalk zone. iii. Awnings and canopies may project over the sidewalk zone with an encroachment permit. iv. Where the sidewalk width requirement exceeds the width of the public right-of-way the development must provide a setback to achieve the required width. If additional area is required on private property to satisfy the minimum requirement, an easement shall be required. c. Building adjacent zone. Where a public realm is required, there shall be a minimum four-foot building adjacent zone width measured from the sidewalk zone to the building frontage for public realm setbacks of 15 feet, and a two-foot building adjacent zone for public realm setbacks of 12 feet. This area exists between the sidewalk and the building-to-line, as specified in Figures 30.16.050-A. i. Landscaping, permanent or temporary seating, and low fences and walls (no greater than three feet in height), shall be permitted in the building adjacent zone, except when prohibited by Section 30.16.050(B)(4)(a). ii. Accessory ground signs shall be permitted in the building adjacent zone. iii. Building floors above the first floor may project over the building adjacent zone. iv. Walls and stairs greater than three feet in height are prohibited in the building adjacent zone, except for above-grade first residential floors (see Section 30.16.050(B)(4)(b)). v. Subterranean parking garages may be located within the building adjacent zone below grade. If landscaping is required within the building adjacent zone, the subterranean parking garage shall be depressed a minimum of two feet from the adjacent sidewalk grade for the building adjacent zone to allow for adequate landscaping planting soil depth. FIGURE 30.16.050-APUBLIC REALM STANDARDS [image] B. Site Planning: Building Setbacks. 1. Street front and street side setback exceptions. No person shall construct, locate, or maintain within the space between the required public realm area and the build-to line established by ordinance or by this title, any building, wall, fence, other improvement, or structure with the following exceptions: a. Driveways and walkways, provided that a driveway shall be limited to that area reasonably necessary to provide safe and efficient ingress to and egress from off-street parking spaces located behind a setback area; b. An awning or canopy; c. Flagpoles, limited to one per site; d. Footings and public utility vaults if fully subterranean; e. Accent lighting for landscaping and buildings not to exceed 18 inches in height; f. Necessary railings adjacent to stairways; g. Retaining walls, planters or curbs which are not more than 24 inches in height above the ground surface existing at the time of construction; h. Subterranean parking garages including equipment, service, utility and storage areas may extend to the street property line provided such areas do not have any door or other opening to the outside along the street property line. 2. Ground floor nonresidential street setbacks. The following setback standards from the build-to line apply to all nonresidential street frontages, and ground floor nonresidential portions of mixed use buildings, in all TOD districts, as specified in Figures 30.16.050-B and 30.16.050-C, except for portions of a building fronting areas dedicated as publicly accessible open space (see Section 30.16.050(A)(1)). The setback is measured from the build-to-line to the ground floor face of the building wall. a. There is no minimum setback required from the build-to line. The maximum setback allowed is 10 feet, except for publicly accessible open space adjacent to the public realm. b. If a setback is provided, this area shall only be used for landscaping, active pedestrian areas (e.g., plazas, outdoor dining) and required circulation. c. Setback areas shall be accessible to the public at all hours on all days. d. Non-subterranean parking, loading, or storage areas are prohibited in the street setback. e. Any setback area greater than two feet in width shall be composed of landscaping, planting beds, lawns, or decorative paving for walkways, driveways and outdoor seating areas. f. Permanent screening walls or fences greater than three feet in height are prohibited within the setback. [image] [image] 3. Nonresidential setbacks above the ground floor. There is no additional setback requirement. 4. Ground floor residential setback standards. These standards are applicable for all ground floor residential uses adjacent to the public realm. Setback requirements do not apply to façades that are directly adjacent to publicly accessible open space fronting the public realm. If a setback is required, the setback is measured from the build-to line to the ground floor face of the building wall. a. At-grade ground floor residential uses. These standards are applicable where the finished ground floor elevation of fronting residential uses is within 30 inches of the existing finished grade of the adjacent public realm, as specified in Figures 30.16.050-D and 30.16.050-E. i. A minimum five-foot average setback from the build-to line is required. Pilasters, columns, or other architectural articulation projections, not exceeding 12 inches wide, may project a maximum of 12 inches from the adjacent building wall into the ground floor setback. The maximum setback allowed for at-grade ground floor residential uses is 10 feet. ii. The ground floor residential setback shall be fully landscaped with a combination of live plant material with varied heights, except for driveways, required walkways and private patio areas. Decorative paving shall be required for all walkways and driveways in this setback area. iii. Not more than 50 percent of the required ground floor residential setback, excluding driveways and walkways, may be used towards private residential open space. Such private patios shall be a minimum of four feet in depth and 40 square feet. Walls and fences not greater than 42 inches in height shall be permitted for private residential open space patios within the street setback. A minimum 12-inch wide landscaping buffer with landscaping of various heights shall be provided between the build-to line and any private residential open space or patio. iv. All building adjacent zone areas directly adjacent to at-grade ground floor residential units shall be landscaped at-grade or within planters less than two feet in height, except for required walkways and building entrances. [image] [image] b. Above-grade ground floor residential uses. These standards are applicable where the finished ground floor elevation of fronting residential units is between a minimum of 30 inches to a maximum of 48 inches above the existing adjacent public realm. i. No setback is required from the build-to line for above-grade residential uses fronting the adjacent public realm. Such above-grade ground floor residential uses shall include stoops, porches, terraces, balconies, or a combination of these elements. ii. The building adjacent zone and any setback provided in front of steps, stoops, porches, terraces, or balconies for above-grade ground floor residential uses shall be landscaped at-grade or include decorative planters less than two feet in height except for required walkways, building entrances, stairs and ramps. [image] [image] 5. Allowed setback projections for residential uses above at-grade ground floor residential uses. a. Upper residential floors are permitted to project, cantilever, or extend above the first floor residential setback a maximum of 50 percent of the minimum five-foot average setback for at-grade ground floor uses (see Section 30.16.050(B)(4)(a)(i)). C. Site Planning: Publicly Accessible Open Space. All new projects in any TOD zoning district shall provide publicly accessible open space in compliance with the following standards: 1. Publicly accessible open space is required for development sites with frontage widths 60 feet or greater. 2. Development sites shall comply with the open space requirements in Table 30.16.050-A to provide a minimum percentage of publicly accessible open space based on gross site area. a. Exceptions: For projects where a public easement is required in order to comply with the public realm setback standard, the area for the public easement may be excluded from the development site area to calculate the minimum required publicly accessible open space. For residential projects where a setback is required, the area for the required setback may be excluded from the development site area to calculate the minimum required publicly accessible open space. b. Exclusions. The following shall not be included in the publicly accessible open space calculation: i. Building adjacent zones. ii. Pedestrian circulation areas (paths of travel, etc.) that exceed 10 percent of the total contiguous open space area. iii. Private outdoor dining areas, separated by physical barriers such as railing or fencing, that exceed 25 percent of the publicly accessible open space area. iv. Area occupied by subterranean garage ventilation or utilities (back flow preventers, electric meters, etc.). 3. A minimum of 85 percent of the required publicly accessible open space shall be in a contiguous space, either in the form of courtyard, plaza or paseo, which shall comply with the following dimension standards: a. Publicly accessible open space courtyards and plazas shall have a minimum area of 1,200 square feet and minimum dimensions of 30 feet by 40 feet, except if the required area is less per Section 30.16.040(C). In such instances, the length of the courtyard or plaza shall be approximately the same as its width. b. Paseos shall maintain a width of at least 20 feet but no greater than 30 feet. The directly adjacent building walls framing the paseo may not be greater than three times in elevation height than the width of the paseo. The building above this height must be setback a minimum of 20 feet. 4. Courtyards, plazas and paseos shall be at the same elevation as the adjacent public realm and shall comply with the following accessibility standards: a. Courtyards and plazas shall be adjacent and open to a public street and sidewalk of a primary building façade, on one or two-sides (courtyard or plaza) with an unobstructed opening dimension of 30 feet on any open side, unless as noted. An alley shall not be considered a public street. b. Paseos shall abut the public right-of-way, be physically and visually accessible from the public realm, and shall connect a public street with a different public street or alley. Vehicular access, loading, and parking uses shall be prohibited within the paseo during hours of public accessibility. 5. A minimum of 90 percent of all publicly accessible open space courtyards and plazas shall be open to the sky. Paseos, provided as publicly accessible open space, shall be open to the sky a minimum of 75 percent. No permanent building projections, including cantilevered overhangs or balconies, may occupy or project more than 24 inches into this space at any level of the building. 6. All publicly accessible open space shall comply with the design standards in Section 30.16.080(A). Table 30.16.050-ATRANSIT ORIENTED DEVELOPMENT DISTRICTS PUBLICLY ACCESSIBLE OPEN SPACE REQUIREMENTS Street Frontage or Site Acreage | Publicly Accessible Open Space Requirement as Percentage of Gross Site Area Greater than 60 feet | 10 Greater than two acres | 15 [image] D. Site Planning: Parking Design and Access Standards. This section regulates the location, ingress and egress, screening, and the total lot area allowed for parking. Parking, loading, and vehicular circulation should be located to minimize its visibility from the public realm. All required parking shall comply with the standards in Chapter 30.32 (Parking and Loading). All off-street parking and loading areas located in the TOD zones shall be designed and developed consistent with the following standards contained in this section. 1. At-grade parking. The amount of at-grade parking permitted is determined by total street frontage length. a. At-grade parking area calculation. i. One hundred feet or less of total street frontage. On development sites with 100 linear feet or less of street frontage, a maximum of 80 percent of the development site area may be occupied by at-grade parking. ii. More than 100 feet of total street frontage. On development sites with more than 100 feet street frontage, up to 60 percent of the development site area may be occupied by at-grade parking. b. Maximum permitted at-grade parking area shall include: i. Stalls for vehicular parking and loading and circulation lanes. ii. Internal or covered parking access driveways. iii. Parking related facilities such as those that provide ventilation for exhaust or mechanical equipment. iv. Bicycle parking areas or facilities less than 200 square feet shall not be included in the maximum permitted at-grade parking area calculation. c. Required screening for at-grade parking: Refer to Section 30.16.050(D)(3). 2. Driveway locations. Driveways for vehicular ingress and egress shall comply with the standards in this section. The number, width, and frequency of curb cuts and vehicular entries shall be limited to promote street wall continuity and reduce conflicts with pedestrians. Vehicular access should be designed such that it does not discourage or inhibit the pedestrian experience and circulation. a. All development sites. i. The driveway shall be located no more than 25 feet from an interior lot line for properties located at street intersections to allow for adequate queuing and visibility. ii. Shared or combined vehicular entries for parking and loading are permitted and shall not be wider than 22 feet to allow access in and out of a development site or building. Loading activities may not encroach on or interfere with the use of sidewalks, drive aisles, queuing areas, or parking areas. iii. All driveway entries shall comply with the screening requirements per Section 30.16.050(D)(3) (At-Grade Parking Screening and Parking Garage Openings). b. Parking access from alley. Vehicular access to a parking area shall be provided from an alley if the alley has an adequate width to provide such access in compliance with the Department of Public Works standards for alley width and capacity. For development sites without adequate alley access, see Section 30.16.050(D)(2)(c) for parking access standards. i. For sites greater than one acre and with alley access and street frontage along San Fernando Road, an additional driveway may be permitted on San Fernando Road if required by the Director of Public Works. [image] c. Parking access from street for lots without alley access. The following standards are applicable to all development sites where no adjacent, adequate alley is present: i. On mid-block development sites without an alley and with only one street frontage, parking access shall be from the street. ii. On through-block development sites without an alley and with two street frontages, parking access shall only be from one street frontage. iii. On corner development sites without an alley and which have two street frontages, and which have less than one acre in total gross lot area and less than 200 feet of street frontage on either side, a single driveway is permitted on only one street frontage of the development site. iv. On corner development sites without an alley and which have two street frontages, and which are greater than one acre in total gross lot area and have 200 feet or more of street frontage on either side, a driveway shall be permitted on each street frontage. v. On corner development sites without an alley and which have three or more street frontages, a maximum of two driveways shall be permitted. Driveways on the same street frontage shall be separated a minimum of 120 feet between interior driveway edges. FIGURE 30.16.050-JPARKING ACCESS - DEVELOPMENT SITE WITHOUT ALLEY ACCESS [image] 3. Parking screening and parking garage openings. a. Parking screening. Except for parking structures for hospitals, all off-street parking and loading areas shall be fully integrated into the design and form of a project and shall be fully screened from public streets and publicly accessible open space to limit the visual and environmental impact of vehicular use areas on the public realm. The following screening standards are applicable to all new developments, except for parking structures for hospitals: b. Active ground floor use screening for at-grade parking. i. At-grade parking and loading on the ground floor level of new buildings shall be located behind active ground floor uses fronting the street, except for driveway areas and screening walls in compliance with Section 30.16.050(D)(3)(c), so that no portion of the parking facility shall be visible from adjacent public sidewalks or publicly accessible areas. Active ground floor uses shall include residential and/or commercial uses, including building lobbies. ii. All active ground floor uses along street facing building elevations used for parking screening shall have a minimum depth of 20 feet, as measured perpendicular to the street wall of a building, except for driveway areas and screening walls in compliance with Section 30.16.050(D)(2). iii. Active ground floor uses may include the following: utility rooms, stairs, elevators, storage, bike rooms, or service areas such as trash rooms, laundry, etc. and such areas shall not comprise more than 20 percent of the ground floor façade along the street frontage and the façade of these areas shall be integrated with the overall design of the project. c. Building at-grade parking screening walls. i. All at-grade parking and loading areas not screened by active ground floor uses shall be screened using an integrated façade design treatment so that the parking and loading areas are not visible from any adjacent public sidewalk or publicly accessible area. ii. Street fronting screening walls shall not exceed 20 percent or 20 linear feet in cumulative length along the street-facing lot frontage, whichever is less, where parking vehicular access is permitted. For sites larger than one acre, only the 20 percent maximum shall apply. The screening wall frontage shall include architectural form, massing, articulation, material, color, and other treatments such as a vertical living green wall that result in a unified façade composition with the building. d. Screening for above-ground parking. All above-ground parking shall be fully screened along all street frontages by residential or nonresidential architectural façades, except for any future parking structures for Glendale Transit Center and in the TOD II zone. Such parking structures shall comply with Sections 30.32.110 and 30.34.120. e. Parking garage openings. All entrances to parking garages shall comply with the following: i. Garage doors or gates shall be provided at all driveways, except for hospital parking structures. ii. Garage doors and gates shall be set back a minimum of three feet from the face of a building, except for garage doors fronting alleys, which shall be set back a minimum of five feet from the alley and comply with Section 30.32.100(F). iii. Garage doors and gates shall be integrated into the architectural design of the building or wall to reduce the aesthetic impact on the pedestrian realm. iv. Garage doors and gates shall be a maximum 50 percent opaque. v. Residential garage doors and gates shall be closed at all times when vehicles are not entering or exiting. vi. Electronically activated garage door or gate access control key pads, intercom, or card reader or security systems shall be located adjacent to ingress and egress drive lanes and shall not obstruct the vehicular or pedestrian path of travel. vii. Parking garage entrances located on streets frontages shall provide audio alarm systems to warn pedestrians that a vehicle is exiting. f. Parking structures for hospital uses in the TOD II district. All new parking structures for hospital uses in the TOD II district shall comply with the parking structure standards in Sections 30.32.110 and 30.34.120.

( Ord. 6012 , 10/10/2023 )

Ask a question about Glendale law

Corpus searches the Glendale sections it holds and shows the ones that match, with their citations. Free, no sign-in.