For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30.16.070 — TOD district architectural elements

Code of Ordinances, City of Glendale, California (Code 2026-05-19) · Glendale Code of Ordinances § 30.16.070

Corpus is an independent public-information project, not the official City of Glendale website. Stable reference: corpuslaw.us/code/bc93d6c1-565f-43c4-8389-05d34650bd51

§ 30.16.070: TOD district architectural elements.

All new developments and all façade remodels shall comply with the following architectural element standards: A. Architectural Elements: Façade Materials and Colors. Materials are a significant feature of design and are used to establish a unique aesthetic quality and character of a building. Materials are essential to diminish the massing and scale of a building and reinforce the base-middle-top principles of quality design. Materials at the ground floor, or base, shall reinforce the pedestrian character of the public realm and employ materials that are of a human-scale. Except where portions of a building directly abut an existing building on- or off-site, all façades shall comply with the following materials and colors standards: 1. All building elevations, including those walls fronting the public realm, publicly accessible open space, and alleys, shall be treated equally with materials to provide textural and color variation. 2. All exterior wall façades shall have a minimum of two cladding materials. All cladding materials shall terminate at an interior corner junction. 3. All projects shall use more than one finish color. Contrasting colors for windows, doors and trim are highly encouraged. 4. Façades shall include colors or material changes that correlate with massing and scale, and façade modulation standards. Changes at building base, middle, or top divisions or with horizontally articulated façade recesses or projections shall be emphasized. 5. Non-durable synthetic stucco, such as Exterior Insulating Finishing Systems (EIFS), shall be prohibited at the ground floor level for all buildings. Stucco shall be prohibited at the ground floor level for all residential buildings, and a maximum of 50 percent of stucco shall be permitted at the ground floor level for nonresidential buildings and mixed-use buildings with nonresidential uses at the ground floor. 6. Above the ground floor, no more than 60 percent of any building total façade area shall be clad with synthetic stucco-EIFS or stucco. 7. All vents, gutters, downspouts, flashing, etc., shall be painted to match the color of the adjacent surface. All new buildings shall feature internal leaders for roof drainage and architecturally integrated vents on all street-facing elevations. On street-facing or alley-facing elevations, all exterior vents shall be integrated into soffits or ceilings of balconies, where such features exist. B. Architectural Elements: Storefront Transparency. All nonresidential façades shall be designed to engage the street and generate activity and transparency between the pedestrian realm and businesses. This section does not apply to residential façades, and to broadcasting studio and indoor support facilities (production), warehouse, light manufacturing and heavy manufacturing buildings. All nonresidential façades shall comply with the following transparency standards: 1. Façades that face the street or publicly accessible open space are required to provide a minimum of 75 percent transparency along Central Avenue, San Fernando Road, and Los Feliz Road, and a minimum of 60 percent transparency on all other streets, as specified below: a. No dark-tinted or opaque glazing for any required wall opening (i.e., doors and windows, except driveways) along street level façades is allowed. Dark-tinted and opaque windows shall be defined as having less than a minimum visible transmittance of 70 percent, including any tint, treatment, or application on glazing in accordance with standards established by the National Fenestration Rating Council. b. Spandrel glass, façade mounted public art or living landscaped green walls, or combination thereof, may be used to count towards a maximum of 25 percent of the required transparency standard. 2. The following shall be used to determine the required façade transparency area: a. The horizontal length of the frontage shall only include the HVAC-conditioned nonresidential portions of the façade that are located on the ground floor and front a street or publicly accessible open space. b. The horizontal length measurement excludes any ground floor residential use frontages, utility rooms, stairs and elevator shafts, loading, parking access driveways, or garage doors. c. The vertical height of the façade frontage used for calculating the transparency requirement shall be measured between the adjacent finished floor and the finished ceiling. d. All window and door parts including the frame, jamb, head, sill, mullions, muntins, and glazing shall comprise an opening. Any decorative window or door trim around the window or door frame shall be not included as part of the opening calculation. 3. Where it is infeasible to provide glazing, such as a parking garage building screening wall, trash room, mechanical room, or utility room, landscaping with a minimum dimension of 18 inches in depth and a width equivalent to 75 percent of the wall, where door access is not required, shall be provided to soften the appearance of a blank wall on the ground floor. Landscaping shall have a minimum mature height of four feet within three years of planting or climbing vines to achieve a wall screening with a minimum wall coverage of 75 percent. FIGURE 30.16.070-ANON-RESIDENTIAL STOREFRONT TRANSPARENCY STANDARDS [image] [image] C. Architectural Elements: Building Entries and Lobbies. Building entries and lobbies provide visual cues to building entrances and landmarks for pedestrians. Entries and lobbies can be used to generate visual interest and modulation in a building façade. Building entries and lobbies shall be designed to create visual reference points that emphasize the building entrance in compliance with the following standards: 1. All building entries and lobby entrances. The following standards apply to all ground floors entries of a new building: a. Entries and lobby entrances shall incorporate at least one design feature such as a canopy, marquee, or other architectural feature that creates visual prominence. b. The primary entrance path to a building lobby entrance shall be distinct and unique from the adjacent public realm paving. c. Primary building entries shall be directly accessible from the public realm or publicly accessible open space. Primary entrance(s) that front publicly accessible open space shall have direct sightlines and a path of continuous and unobstructed pedestrian access to the public realm. d. Primary building entries are prohibited from alleys, driveways, at-grade parking lots, or parking structures. e. Wheelchair ramps or wheelchair lifts (elevator), when required, shall be architecturally integrated into the design of the building and site plan. FIGURE 30.16.070-BNON-RESIDENTIAL BUILDING ENTRIES [image] 2. Residential entries. The following standards apply to the ground floor residential portions of street-facing or publicly accessible open space-facing elevations of residential or mixed-use buildings. For residential uses, the primary entrance of a building is defined as a door or doors which provide primary access to a ground floor residential lobby. Individual entries are also permitted for private residential units. a. Multi-family residential building lobbies shall be located at the ground floor and directly accessible from the public realm, publicly accessible open space, or residential setback. b. Individual unit entries fronting the adjacent public realm shall be setback a minimum of five feet from the build-to line. c. Individual residential entries are permitted to be accessed directly from the public realm and shall have a minimum walkway, ramp, and/or stairs width of four feet for single unit entries. d. Entry porches, stoops, and terraces, not including stairs, for individual entries, shall be a minimum of 20 square feet. FIGURE 30.16.070-BRESIDENTIAL ENTRIES [image] D. Architectural Elements: Canopies, Awnings and Marquees. Canopies, awnings and marquees function as an extension of the public sidewalk, providing shade, shelter from inclement weather, and a sense of enclosure to the public realm. Such elements also provide a visual reference to entrances or other important façade elements. All new canopy, awning and marquees installations shall comply with the following standards: 1. A minimum of 50 percent of the street elevations for ground floor nonresidential uses shall include canopies, awnings or marquees, where the nonresidential tenant space is directly abutting the public realm or the publicly accessible open space, except when the nonresidential uses are recessed from the floors above by an arcade a minimum of six feet. 2. Public realm fronting canopies, awnings or marquees shall be installed a minimum of eight feet and a maximum of 14 feet above the public realm grade, measured from the bottom of the canopy or awning to the adjacent grade. 3. Ground floor public realm fronting canopies, awnings or marquees are permitted to project beyond street front property lines. Canopy supporting posts or columns are prohibited within the public realm. 4. No more than two materials and two colors shall be utilized for all new canopies, awnings and marquees. 5. Interior-illuminated vinyl awnings are prohibited. Any integrated light fixture within a canopy or awning shall direct light downward toward the sidewalk or façade. E. Architectural Elements: Balconies. Balconies provide important outdoor private space for residential units and visual interest to façade designs, in addition to depth and rhythm. All new balconies shall comply with the following standards: 1. All balconies shall be recessed into the adjacent building façade plane. The maximum projection shall be 50 percent of the balcony's full depth or five feet, whichever is less. 2. No balconies shall project over the public right-of-way or public realm sidewalk zone. 3. All balconies shall include facias and soffits. See Section 30.16.070(A)(7) for venting systems built into the soffits. F. Architectural Elements: Fenestration. Fenestration is the arrangement, proportioning, and design of windows and doors in a building. Fenestration patterns foster an identifiable building character and promote quality design. Window designs enhance façade modulation and emphasize changes in scale and materials. All fenestration patterns, including any glazed openings, window, and door frames shall correlate with massing and scale standards in Section 30.16.050. All new window and door openings shall comply with the following standards: 1. Residential. For residential uses, a minimum of 50 percent of all window and door openings between the ground floor and 50 feet above grade shall be recessed or project a minimum of two inches. The recess shall be measured from the outer face of the window or door glazing to the outer edge of the primary façade cladding surface. Internal grid windows and EIFs clad window trim are prohibited. 2. Nonresidential. a. Uninterrupted ground floor storefront or curtain wall window and door systems shall be limited to a maximum of 50 feet in length. b. Storefront systems and curtain walls shall be recessed a minimum of six inches from the primary façade, columns, or pilasters of the building where buildings are constructed at the build-to line. G. Architectural Elements: Freestanding Walls, Fences and Gates. Freestanding walls, fences, and gates define and screen yards, walkways, and outdoors areas. Design of all freestanding walls, fences, gates shall minimize the visual impact of parking facilities, provide privacy, and security. As such, the design of such barriers must be considered when addressing the streetscape experience. All walls, fences, and gates shall comply with Section 30.30.010 and the following standards: 1. The design of all freestanding fences, walls, gates, and garage doors shall match and be integrated with the overall building design and shall be a maximum 50 percent solid, when visible from the public realm, with the exception of fences, walls and gates adjacent to alleys that may exceed the 50 percent maximum. 2. All freestanding exterior gates or fences shall be located a minimum of two feet behind any build-to line or the adjacent street-fronting building façade plane, whichever is setback farther from the street front or side street property line. 3. All freestanding at-grade parking lot screening walls and fences shall be a minimum of four feet and a maximum of eight feet in height. 4. All driveway gates fronting the public realm shall be equipped with vehicle activated warning beacons, bells and light devices. 5. Chain link fences are prohibited. H. Architectural Elements: Trash Enclosures. Trash enclosures are necessary to ensure that trash areas are properly screened from public view. Trash enclosures shall comply with the Section 30.30.030 and the following standards: 1. Trash collection areas shall be located away or screened from adjacent streets. 2. Where possible, trash enclosure shall be enclosed within the building. 3. Trash enclosures are not permitted adjacent to any publicly accessible open space area or public realm. 4. Sizes and dimensions of trash enclosures shall be regulated by the Building and Safety and Integrated Waste Divisions. I. Architectural Elements: Utilities. Utilities are necessary to the function and operation of any building. They can also, when not properly integrated, detract from the aesthetic quality of an urban environment or pose hazards to pedestrians. All utility installations shall comply with the following standards: 1. All mechanical equipment, including electrical and gas meters, shall be screened from view from the public realm and publicly accessible open space. The screening system shall be integrated with the overall site building design. 2. Gas, water, and electrical meter panels are prohibited to project into the public realm. Gas, water, and electrical utilities shall be integrated into the building façade and not freestanding. 3. Electrical transformers shall be either underground, enclosed within the building, or located adjacent to alley wherever present. 4. If electrical transformers are located fronting the public realm, transformers shall be enclosed and incorporated as part of the building façade or screened by a combination of landscaping and decorative walls. Landscaping shall be composed of tall shrubs with a minimum mature height of four feet within three years of planting or climbing vines to achieve a wall screening with a minimum wall coverage of 75 percent. 5. Electrical transformers, mechanical equipment, backflow prevention devices, and other utility equipment shall not be located within or directly adjacent to a designated publicly accessible open space, or within the building adjacent zone. J. Architectural Elements: Outdoor Lighting. Lighting can create a unique aesthetic, highlight the design of a building, provide Illumination for business operations, and enhance safety for pedestrians and other users, while minimizing impacts of light glare, pollution and trespass. All new lighting shall comply with the following standards: 1. Outdoor light fixtures shall be fully shielded from the top so that light is directed downward and confined to the development site. Outdoor light shall not spill over onto adjacent properties or the public realm. 2. Lighting shall not exceed the maximum permitted building height of the applicable TOD district. Lighting for uncovered parking areas, vehicle accessways and walkways shall not exceed a height of 16 feet, and the current Glendale Building & Safety Code. K. Architectural Elements: Rooftop Equipment. All rooftop equipment shall comply with Section 30.30.020(B) Rooftop equipment that is not able to be concealed within the architecture of the building shall be located a minimum of 20 feet away from any building edge and screened from view behind a parapet wall or through the use of screens. Solar energy equipment, as defined in this title, shall not be considered rooftop equipment. L. Solar Energy Equipment. All solar energy equipment must comply with Section 30.30.050 (Solar energy equipment).

( Ord. 6012 , 10/10/2023 )

Ask a question about Glendale law

Corpus searches the Glendale sections it holds and shows the ones that match, with their citations. Free, no sign-in.