For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10-1.205 — DETACHED RESIDENTIAL, DUPLEX, AND TRIPLEX MINIMUM DESIGN STANDARDS

Hayward Municipal Code (Supp. No. 28, Update 2: codified through Ordinance No. 26-08, adopted August 18, 2026) · Hayward Municipal Code § 10-1.205

Corpus is an independent public-information project, not the official City of Hayward website. Stable reference: corpuslaw.us/code/c54ec118-9c16-40e4-8381-699eb2475a03

SEC. 10-1.205 - DETACHED RESIDENTIAL, DUPLEX, AND TRIPLEX MINIMUM DESIGN STANDARDS.

a. Building Massing. (1) In the RNP and RL Districts. a) If the building is less than or equal to 3,000 gross square feet, the floor area of the second floor shall not exceed 80 percent of the gross floor area of the first floor. b) If the building is greater than 3,000 gross square feet, the floor area of the second floor shall not exceed 75 percent of the gross floor area of the first floor. (2) In the RM and RH Districts, the floor area of the third floor shall not exceed 80 percent of the gross floor area of the first floor. (3) For the purposes of this standard, the first floor shall be considered the floor where the garage is located. If the garage is detached from the primary structure or if there is no garage, the first floor shall be considered the floor where the primary entrance is located. The second and third floors shall be considered the floors above the first floor. [image omitted; see the official code] b. Façade Design. All buildings, excluding accessory structures, shall incorporate a combination of any of the following design elements to achieve a minimum of 50 points. Partial points will not be awarded for partial design elements. TABLE 10-1.205.1: FACADE DESIGN ELEMENTS AND ASSOCIATED POINTS VALUE Design Element | Points Value Variation of street-facing front façade plane by a minimum depth of 24 inches for the entire height of the structure | 30 At least every 30 feet along the street facing front building façade, horizontal eaves shall be broken by at least one of these strategies: | 30 • Inclusion of gables • Change in the roof height by a minimum of 2 feet • Inclusion of dormer windows A covered porch for each unit entrance with a minimum landing depth of 5 feet (excluding stairs), minimum landing width of 8 feet (excluding stairs), and minimum clear floor-to-ceiling height of 8 feet | 30 At least two distinct building materials that each make up at least 25 percent of the total building façades | 20 At least one balcony for all street facing units with no dimensions less than 5 feet | 20 A projected stoop for each unit entrance with a minimum overhang projection of 3 feet from the façade plane, minimum landing depth of 5 feet (excluding stairs), minimum landing width of 5 feet (excluding stairs), and minimum clearance of 8 feet from top of the landing to the underside of the overhang/canopy | 20 Windows covering at least 20 percent of the total surface area of the street-facing front façade | 20 At least one bay window or box window along the street-facing front façade with a minimum projection of 18 inches from the façade | 10 Window moldings at least 4 inches wide on all windows | 10 Use of shutters on at least 50 percent of street-facing windows | 10

(Amended by Ordinance 24-01, adopted Jan. 23, 2024)

Ask a question about Hayward law

Corpus searches the Hayward sections it holds and shows the ones that match, with their citations. Free, no sign-in.