§ 10-1.206 — MULTI-UNIT RESIDENTIAL (4+ UNITS) MINIMUM DESIGN STANDARDS

Hayward Municipal Code (Supp. No. 28, Update 2: codified through Ordinance No. 26-08, adopted August 18, 2026) · Hayward Municipal Code § 10-1.206

Corpus is an independent public-information project, not the official City of Hayward website. Stable reference: corpuslaw.us/code/b8dc0ff4-537d-4884-9f46-4d77442b3b4a

SEC. 10-1.206 - MULTI-UNIT RESIDENTIAL (4+ UNITS) MINIMUM DESIGN STANDARDS.

a. Building Massing. (1) Floor area of the fourth and fifth stories each shall not exceed 85 percent of the gross floor area of the first floor. For the purposes of this standard, the first floor shall be considered the floor where the primary entrance is located. The upper floors (second, third, fourth, fifth) shall be considered the floors above the first floor. (2) Facades between 75 and 125 feet long shall have vertical breaks using recesses or projections of the facade plane that are at least 8 feet wide and 2 feet deep for the height of the structure at least once every 75 feet. (3) Facades that equal to or greater than 125 feet long shall have vertical breaks using recesses or projections that are at least 15 feet wide and 10 feet deep for the height of the structure at least once every 125 feet. b. Facade Design. All buildings, excluding accessory structures, shall incorporate a combination of any of the following design elements to achieve a minimum of 100 points for developments up to 10 dwelling units or a minimum of 125 points for developments with 11 or more dwelling units. Partial points will not be awarded to partial design elements. TABLE 10-1.206.1: FACADE DESIGN ELEMENTS AND ASSOCIATED POINTS VALUE Design Element | Points Value Balconies on at least 50 percent of street facing units with no dimensions less than 5 feet | 50 A covered porch for each ground floor unit with a minimum landing depth of 5 feet (excluding stairs), minimum landing width of 8 feet (excluding stairs), and minimum clear floor-to-ceiling height of 8 feet | 50 A projected stoop for each ground floor unit with a minimum overhang projection of 3 feet from the façade plane, minimum landing depth of 5 feet (excluding stairs), minimum landing width of 5 feet (excluding stairs), and minimum clearance of 8 feet from top of the landing to the underside of the overhang | 35 A projected stoop for the primary building entrance with a minimum overhang projection of 5 feet from the façade plane, minimum landing depth of 5 feet (excluding stairs), minimum landing width of 8 feet (excluding stairs), and minimum clearance of 8 feet from top of the landing to the underside of the overhang | 35 At least one of the following building material treatments: | 35 • Use of a siding or cladding material on the ground floor building facades that differs from the materials used above the ground floor • Use of at least two distinct building materials that each make up at least 25 percent of the total building facades Variation in roof height or parapet by at least 2 feet | 35 Roof overhang of at least 2 feet along all street-facing facades | 35 Upper story step back of at least 5 feet along at least 75 percent of street-facing facades | 35 Use of horizontal window overhangs with a depth of at least 18 inches covering the entire length of the window on at least 25 percent of street-facing windows | 35 Windows covering at least 20 percent of the total surface area of the street-facing front facade | 35 Cornices along the top of all building facades that are at least 6 inches deep | 25 At least one sconce light fixture every 15 feet along the street-facing façades | 25 At least one horizontal decorative band that is either: | 20 • Building material that is different from abutting façade materials • Projects at least 2 inches along at least 50 percent of the building facades Window moldings at least 4 inches wide on all windows | 20 Use of shutters on at least 50 percent of street-facing windows | 20

(Amended by Ordinance 24-01, adopted Jan. 23, 2024)

Ask a question about Hayward law

Corpus searches the Hayward sections it holds and shows the ones that match, with their citations. Free, no sign-in.