§ 9-4.110 — GENERAL CONSTRUCTION STANDARDS
Hayward Municipal Code (Supp. No. 28, Update 2: codified through Ordinance No. 26-08, adopted August 18, 2026) · Hayward Municipal Code § 9-4.110
Corpus is an independent public-information project, not the official City of Hayward website. Stable reference: corpuslaw.us/code/4f8e4a52-cc48-4ffc-9c33-54e481f3f8ee
SEC. 9-4.110 - GENERAL CONSTRUCTION STANDARDS.
In any area of special flood hazard, compliance with the following standards is required: (a) Anchoring. (1) All new construction and substantial improvements shall be adequately anchored to prevent flotation, collapse, or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. (2) All manufactured homes shall meet the anchoring standards of subdivision 9-4.140(b). (b) Construction Materials and Methods. All new construction and substantial improvements shall be constructed utilizing methods and practices that minimize flood damage, including the following: (1) Use flood resistant materials specified in FEMA Technical Bulletin TB 2-93 and amendments thereto. (2) Utility equipment shall be resistant to flood damage. (3) Electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. (4) Construction and substantial improvements to properties located within Zones AH and AO shall include adequate drainage paths around structures on slopes to guide flood waters around and away from proposed structures. (c) Elevation and Flood-Proofing. (1) Residential Construction structures. The lowest floor in any new or substantial improvement of any residential structure shall meet the requirements specified below. Upon completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered professional civil engineer or licensed land surveyor, and verified by the community building inspector to be properly elevated. Such certification and verification shall be provided to the Flood Plain Administrator. (i) Zone AO. In an AO zone, the lowest floor shall be elevated to a height which is elevated above the highest adjacent grade to a height which is at or above the depth number specified on the FIRM or at least two (2) feet above the highest adjacent grade if no depth number is specified. (ii) Zone A. In an A zone, the lowest floor shall be elevated to a level at or above the base flood elevation. (iii) All other FIRM Zones. In all other zones, the lowest floor shall be elevated to a height at or above the base flood elevation. (2) Nonresidential structures. The lowest floor in any new non-residential structure or substantial improvement of a non-residential structure, shall either be elevated to meet the requirements of subdivision (c)(1) of this Section 9-4.110, or such structure, together with attendant utility and sanitary facilities shall meet the requirements specified in this subdivision (c)(2) of Section 9-4.110. A registered professional engineer or architect shall certify compliance with such requirements and provide a copy of such certification to the Flood Plain Administrator. (i) The lowest floor of a nonresidential structure, including the basement, shall be floodproofed so that the structure's walls located below the base flood level are substantially impermeable to the passage of water; and (ii) Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. (3) Lowest enclosed areas used for parking or storage. New construction and substantial improvement of any fully enclosed area below the lowest floor used solely for parking of vehicles, building access or storage, shall be designed to automatically equalize hydrostatic flood forces on the exterior, if such areas are subject to flooding, by containing openings which allow for the entry and exit of floodwater in accordance with the guidelines in the FEMA Technical Bulletin TB-193 and TB7-93 and amendments thereto. Designs for meeting the requirements of this subdivision must be certified by a registered civil engineer or architect, as meeting such FEMA guidelines and as exceeding the following minimum criteria: (i) Include a minimum of two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding; with the bottom of all openings no higher than one (1) foot above grade. (ii) Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. (4) Manufactured homes placed within manufactured home parks or subdivision shall also meet the standards in Section 9-4.140. Additional guidance may be found in FEMA Technical Bulletins TB 1-93 and TB 7-93. (5) Garages and low cost accessory structures. (a) Attached garages. (1) A garage attached to a residential structure, constructed with the garage floor slab below the BFE, must be designed to allow for the automatic entry of flood waters. See Section 9-4.110(c)(3). Areas of the garage below the BFE must be constructed with flood resistant materials. See Section 9-4.110(b)(1). (2) A garage attached to a nonresidential structure must meet the above requirements or be dry flood-proofed. For guidance on below grade parking areas, see FEMA Technical Bulletin TB-6. (b) Detached garages and accessory structures. (1) "Accessory structures" used solely for parking (two-car detached garages or smaller) or limited storage (small low-cost sheds), as defined in Section 2, may be constructed such that its floor is below the base flood elevation (BFE), provided the structure is designed and constructed in accordance with the following requirements: a) Use of the accessory structure must be limited to parking or limited storage; b) The portions of the accessory structure located below the BFE must be built using flood-resistant materials. c) The accessory structure must be adequately anchored to prevent flotation, collapse, and lateral movement; d) Any mechanical and utility equipment in the accessory structure must be elevated or floodproofed to or above the BFE; e) The accessory structure must comply with flood plain encroachment provisions in Section 9-4; and f) The accessory structure must be designed to allow for the automatic entry of flood waters in accordance with Section 9-4. (2) Detached garages and accessory structures not meeting the above standards must be constructed in accordance with all applicable standards in Section 9-4.
Ask a question about Hayward law
Corpus searches the Hayward sections it holds and shows the ones that match, with their citations. Free, no sign-in.