Sec. 5-9-401. - Building Code.
A. Fire Protection Systems. Chapter 9 of the California Building Code is hereby amended as follows: 1. Where required. Section 903.2 is hereby deleted and replaced to read: 903.2 Where required. Approved automatic sprinkler systems in buildings and structures shall be provided in the following locations: A. New buildings or structures. Notwithstanding any applicable provisions of Sections 903.2.1 through 903.2.21, an automatic sprinkler system shall also be installed in all occupancies when the total building area exceeds 5,000 square feet as defined in Section 202, regardless of fire areas or allowable area, or is more than two stories in height. Exception: Subject to approval by the fire code official, open parking garages in accordance with Section 406.5 of the California Building Code that are smaller than the area specified in section 903.2.10 (3) or 903.2.10.1 of the California Fire Code. B. Existing Buildings: Notwithstanding any applicable provisions of this code, an automatic sprinkler system shall be provided in an existing building when an addition occurs and one of the following conditions exists: 1. When an addition is 33% or more of the existing building area, and the resulting building area exceeds 5,000 square feet. 2. When an addition exceeds 2,000 square feet, and the resulting building area exceeds 5,000 square feet. 3. An additional story is added above the second floor regardless of fire areas or allowable area. Exception: Additions to Group R-3 occupancies shall comply with Section 903.2.8 (2). 2. Group R. Section 903.2.8 is hereby deleted and replaced to read: 903.2.8 Group R. An automatic sprinkler system installed in accordance with Section 903.3 shall be provided throughout all buildings with a Group R fire area as follows: 1. New Buildings. An automatic sprinkler system shall be installed throughout all new buildings. 2. Existing R-3 Buildings. An automatic sprinkler system shall be installed throughout when one of the following conditions exists: 1. When the floor area of alterations within any two-year period exceeds 50 percent of gross floor area of the existing structure and the building gross floor area exceeds 5,500 square feet; or: 2. When an existing Group R Occupancy is being substantially renovated, and where the scope of the renovation is such that the Building Code Official determines that the complexity of installing a sprinkler system would be similar as in a new building. 3. Hydraulically calculated systems. Section 903.3.5 is hereby amended to add Section 903.3.5.3 to read: 903.3.5.3 Hydraulically calculated systems. The design of hydraulically calculated fire sprinkler systems shall not exceed 90 percent of the water supply capacity. Exception: When static pressure exceeds 100 psi, and required by the fire code official, the fire sprinkler system shall not exceed water supply capacity specified by Table 903.3.5.3. TABLE 903.3.5.3 Hydraulically Calculated Systems [image omitted; see the official code] B. Ventilation. Section 1202 of Chapter 12 of the California Building Code is hereby amended as follows: 1. Openings into attic. Section 1202.2.2 is hereby deleted and replaced to read: 1202.2.2 Openings into attic. Exterior openings into the attic space of any building intended for human occupancy shall be protected to prevent the entry of birds, squirrels, rodents, snakes and other similar creatures. Openings for ventilation having a least dimension of not less than 1/16 inch (1.6 mm) and not more than ⅛ inch (6.4 mm) shall be permitted. Openings for ventilation having a least dimension larger than ⅛ inch (6.4 mm) shall be provided with corrosion-resistant wire cloth screening, hardware cloth, perforated vinyl or similar material with openings having a least dimension of not less than 1/16 inch (1.6 mm) and not more than ⅛ inch (6.4 mm). Where combustion air is obtained from an attic area, it shall be in accordance with Chapter 7 of the California Mechanical Code. 2. Ventilation openings. 1202.4.1 through 1202.4.1.3 are hereby deleted and replaced to read: 1202.4.1 Ventilation openings. Ventilation openings through foundation walls shall be provided. The openings shall be placed so as to provide cross ventilation of the under-floor space. The net area of ventilation openings shall be in accordance with Section 1202.4.1.1 or 1202.4.1.2. Ventilation openings shall be covered for their height and width with any of the following materials, provided that the least dimension of the covering shall be not greater than ⅛ inch (3.2 mm): 1. Perforated sheet metal plates not less than 0.070 inch (1.8 mm) thick. 2. Expanded sheet metal plates not less than 0.047 inch (1.2 mm) thick. 3. Cast-iron grilles or gratings. 4. Extruded load-bearing vents. 5. Hardware cloth of 0.035-inch (0.89 mm) wire or heavier. 6. Corrosion-resistant wire mesh, with the least dimension not exceeding ⅛ inch (3.2 mm). 1202.4.1.1 Openings for under-floor ventilation shall not be less than 1½ square feet (0.135 m2) for each 25 linear feet (7620 linear mm) of exterior wall and shall be covered with corrosion-resistant wire mesh with mesh openings not less than 1/16 inch (1.6 mm) nor more than ⅛ inch (3.2 mm) in any dimension. C. Minimum roof covering classification. Section 1505.1 of Chapter 15 of the California Building Code is hereby amended as follows: 1. Minimum Roof Classification for Types of Construction. Table 1505.1 is hereby deleted and replaced to read: TABLE NO. 1505.1 MINIMUM ROOF ASSEMBLY CLASSIFICATION FOR TYPES OF CONSTRUCTION (1) TYPES OF CONSTRUCTION IA | IB | IIA | IIB | IIIA | IIIB | IV | VA | VB A | A | A | A | A | A | A | A | A 2. Roof coverings within all other areas. Section 1505.1.2 is hereby deleted and replaced to read: 1505.1.2 Roof coverings within all other areas. The entire roof covering of every existing structure where more than 50 percent of the total roof area is replaced within any one-year period, the entire roof covering of every new structure, and any roof covering applied in the alteration, repair or replacement of the roof of every existing structure, shall comply with Table 1505.1. D. Structural Tests and Special Inspections. Chapter 17 of the California Building Code is hereby amended as follows: 1. Special inspector qualifications. Section 1704.2.1 is hereby deleted and replaced to read: 1704.2.1 Qualifications of special inspector, examination and certificate of registration. 1. The special inspector shall be a qualified person approved by the building official. The special inspector shall furnish continuous or periodic inspection on the construction and work requiring his or her employment as prescribed in the applicable code and statement of special inspections. The special inspector shall report to the building official in writing, noting all code violations and other information as required on forms prescribed by the City of Irvine. 2. Each person applying for listing/registration as a special inspector for the City of Irvine shall possess a valid special inspector certificate, issued as evidence of successful completion of testing/examination by a testing agency which is acceptable to the building official, for each classification for which the person is applying. On special occasions, the building official may administer an oral interview and/or appropriate testing for certification. 3. Each person applying for registration as a special inspector for the City of Irvine shall pay a registration fee, as established by resolution of the City Council, for each classification payable with the application upon approval for listing. 4. A registration card shall be issued to each such special inspector who qualifies. A renewal fee, as established by resolution of the City Council, for each classification shall be charged on July 1 of each year, thereafter, at which time the special inspector may, at the building official's discretion, be subject to reexamination. 5. The building official may revoke any special inspector's certificate of registration at any time for due cause on written notice. This notice shall set forth the time and place for a hearing if requested by the special inspector in writing within 10 days of the City's notice of revocation at which time evidence may be submitted to show cause why the certificates of registration should not be withdrawn. 6. Failure to appear at such hearing by the special inspector may result in immediate revocation of said inspector's certificate of registration. 7. Special inspector's qualification registrations are to be given only for the execution of work done under Chapter 17 of the California Building Code in the City of Irvine or for work specifically authorized by the building official. 2. Special inspection of fabricated items. Section 1704.2.5 is hereby deleted and replaced to read: 1704.2.5 Registration and approval of fabricators. Where fabrication of structural, load-bearing or lateral load-resisting members or assemblies is being conducted on the premises of a fabricator's shop, the fabricator must be registered and approved in writing in accordance with Section 1704.2.5.1. 3. Fabricator approval. Section 1704.2.5.1 is hereby deleted and replaced to read: 1704.2.5.1 Fabricator approval. Approval shall be based on review of the fabricator's written fabrication procedures and quality control manuals that provide a basis for control of materials and workmanship, with periodic auditing of fabrication and quality control practices by an approved agency. At completion of fabrication, the approved fabricator shall submit a certificate of compliance to the building official as specified in Section 1704.5 stating that the work was performed in accordance with the approved construction documents. 4. Concrete construction. Section 1705.3 of the California Building Code is hereby amended as follows: 1. Table 1705.3. Item 7 is hereby deleted and replaced to read: 7. Inspect concrete and shotcrete placement for proper application techniques, including all structural concrete placement for new swimming pools. 2. 1705.3 Exception Items 3, 4, and 5 of the exception are hereby deleted and replaced to read: 3. Concrete in building foundations and slabs supported on grade less than 500 square feet in area in all occupancies and other non-building construction. 4. Concrete patios, driveways and sidewalks on grade. 5. (Deleted) E. Swimming Pool, Spa and Hot Tub. Section 3109 of the California Building Code is hereby amended as follows: 1. Swimming pool safety features. Section 115922 of Section 3019.2 of the California Building Code is hereby deleted and replaced to read: (a) Except as provided in Section 115925, subject to subdivision (b), and consistent with Section 1596.814, when a building permit is issued for the construction of a new swimming pool or spa or the remodeling of an existing swimming pool or spa at a private single-family home, the respective swimming pool or spa shall be equipped with Item (1) below and at least one additional drowning prevention safety feature from Items (2)-(6): (1) An enclosure that meets the requirements of Section 115923 and isolates the swimming pool and spa from the private single-family home. Any walls of the residential structure or accessory structures used to complete the isolation enclosure must comply with either Section 115922 (a) (4) or (5). Any such door or window protection device provided for this purpose may not be used to comply with the second drowning prevention feature requirement. (2) Removable mesh fencing that meets the ASTM International F2286 standard in conjunction with a gate that is self-closing and self-latching and can accommodate a key lockable device. (3) A manually operated or power-operated safety pool cover that is accompanied by a label verifying that the cover meets the specifications of the ASTM International F1346-23 standard. (4) Exit alarms on the private single-family home's doors and windows that provide direct access to the swimming pool or spa without any intervening enclosure. Whenever any door or window is opened or left ajar, exit alarms shall make either an audible, continuous alarm sound or a repeating verbal warning, such as a notification that "the door to the pool is open." An exit alarm may be battery operated or connected to the electrical wiring of the building. (5) A self-closing, self-latching device with a release mechanism placed no lower than 54 inches above the floor on the private single family home's doors providing direct access to the swimming pool or spa. (6) An alarm in good repair and operable as designed that, when placed in a swimming pool or spa, will sound upon detection of accidental or unauthorized entrance into the water. The alarm shall meet and be independently certified to the ASTM International F2208 standard that includes surface motion, pressure, sonar, laser and infrared type alarms. A swimming protection alarm feature designed for individual use, including an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water, is not a qualifying drowning prevention safety feature. (7) Other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the features set forth above and has been independently verified by an approved testing laboratory as meeting standards for those features established by ASTM International, the American Society of Mechanical Engineers, or another nationally recognized standards development organization, and the feature is accompanied by a label verifying that the protection meets those standards. (b) The requirements of subdivision (a) are not satisfied by any of the following: (1) An exit alarm and a self-closing, self-latching device on the same door. (2) An exit alarm and a door latch on separate doors. (3) A safety pool cover and an alarm described in paragraph (6) of subdivision (a). (c) Before the issuance of a final approval for the completion of permitted construction or remodeling work, the building official shall inspect the drowning safety prevention features required by this section and, if no violations are found, shall give final approval. 2. Enclosure of yards containing private pools/spas. Section 3019 of the California Building Code is hereby amended to add Section 3109.2.1 to read: 3109.2.1 Enclosure of yards containing private pools/spas. Every person in possession of land within the City, either as owner, purchaser under contract, lessee, tenant, licensee or otherwise, upon which is situated a private swimming pool or other out-of-doors body of water having a depth in excess of 18 inches that is designed, constructed and/or used for swimming, dipping or immersion by men, women or children shall maintain in good condition an enclosure to completely separate the private pool from adjoining properties by fencing complying with Health and Safety Code Section 115923 or building walls, or a combination thereof, substantially constructed, not lower than five feet in height above the surface of the ground measured vertically from the outside grade. Any pool enclosed by a fence or enclosure which does not meet the requirements of this chapter shall be drained immediately and shall not be refilled until such time as the enclosure is brought into compliance with the provisions of this article. All gates opening through the swimming pool yard enclosure shall be equipped with a self-closing and self-latching device designed to keep such door or gate securely closed at all times when not in actual use. Access gates through the enclosure shall open away from the swimming pool. The unlocking or unlatching device shall be located not less than five feet above grade or steps at the gate or door measured vertically outside the enclosed areas and shall include any passage door or gate opening from an accessory building, such as a garage. Exceptions: 1. The unlocking or unlatching device may be located on the inside of the enclosure at less than the required five feet in height when not operable from the outside of the enclosure. 2. Double-gates installed across vehicular access ways shall be self-closing and shall be equipped with a latching device which may be manually operated. Such gates shall be securely closed at all times when not in actual use. F. Vehicular gates or other barriers across required fire apparatus access roads. Section 3110.4 of the California Building Code is hereby added as follows: 3110.4 Vehicular gates or other barriers across required fire apparatus access roads. The installation of gates or other barriers across a required fire apparatus access road shall be approved in writing by the fire code official. Gates or barriers shall be in accordance with the City of Irvine Security Code and the Orange County Fire Authority Guideline B-09 "Fire Master Plans for Commercial and Residential Development."
(Ord. No. 25-26, § 5(Exh. D), 11-12-25)
Ask a question about Irvine law
Corpus searches the Irvine sections it holds and shows the ones that match, with their citations. Free, no sign-in.