§ 5-9-402 — Residential Code
Irvine Municipal Code (Supp. No. 20: codified through Ordinance No. 26-05, adopted February 10, 2026) · Irvine Municipal Code § 5-9-402
Corpus is an independent public-information project, not the official City of Irvine website. Stable reference: corpuslaw.us/code/32f7a88a-25b5-40af-9e7d-e7b3a4b8b562
Sec. 5-9-402. - Residential Code.
A. Definitions. Section R202 of Chapter 2 of the California Residential Code is hereby amended to add the following definitions to read: CITY OF IRVINE SMALL RESIDENTIAL ROOFTOP SOLAR ENERGY SYSTEM EXPEDITED/STREAMLINED PERMITTING PROCESS: A ministerial permitting process in substantial conformance to the California Solar Permitting Guidebook published by the Governor's Office of Planning and Research, applicable to systems meeting the definition of a small residential rooftop solar energy system. For such qualifying systems, the process, including permit issuance, may be conducted entirely online utilizing digital forms or may be conducted over the counter at the City's One-Stop Permit Processing Center utilizing printed forms. OCFA: Orange County Fire Authority, fire authority having jurisdiction. SMALL RESIDENTIAL ROOFTOP SOLAR ENERGY SYSTEM: A residential rooftop solar energy system that meets all of the following: 1. A solar system that is no larger than 10 kilowatts alternating current nameplate rating (PV) or 30 kilowatts thermal (solar water heating). 2. A solar energy system that conforms to all applicable state fire, structural, electrical and other building codes as adopted or amended by the City of Irvine and paragraph (3) of subdivision (c) of Section 714 of the Civil Code. 3. A solar energy system that is installed on a single or duplex family dwelling. 4. A solar panel or module array that does not exceed the maximum legal building height. SPARK ARRESTER: A listed device constructed of noncombustible material specifically for the purpose of meeting one of the following conditions: 1. Removing and retaining carbon and other flammable particles/debris from the exhaust flow of an internal combustion engine in accordance with California Vehicle Code Section 38366. 2. Fireplaces that burn solid fuel in accordance with California Building Code Chapter 28. B. Climatic and Geographic Design Criteria. Table R301.2(1) of Chapter 3 of the California Residential Code is hereby deleted and amended to read: ___________ TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ground Snow Load | Wind Design | Seismic Design Category | Subject To Damage From | Ice Barrier Under- layment Required | Flood Hazards | Air Freezing Index | Mean Annual Temp Speed (mph) | Topographic effects | Weathering | Frost line Depth | Termite Not applicable | 95 | No | D 2 | Negligible | Not applicable | Very Heavy | Not applicable | See footnote a | 0 | 60 a. Date of the City of Irvine entry into the National Flood Insurance Program June 21, 1974. The panel numbers of all FIRMs are: 169, 278, 279, 281, 282, 283, 284, 286, 287, 288, 289, 291, 292, 293, 294, 305, 308, 313, 314, 315, 316, 402, 406, 407, and 426. ___________ C. Fuel modification requirements for new construction. Section R301.9 of the California Residential Code is hereby added to read: R301.9 Fuel modification requirements for new construction. All new structures and facilities adjoining land containing hazardous combustible vegetation shall be approved and in accordance with the requirements of OCFA Guideline C-05 "Vegetation Management Guideline: Technical Design for New Construction, Fuel Modification Plans, and Maintenance Program." D. Site Address. Section R308 is hereby deleted and amended as follows: R308.1 Site Address. New and existing buildings shall have approved address numbers as required by Chapter 5 Uniform Security Code of Division 9 Building Regulations of Title 5 Planning of the City of Irvine Municipal Code. Exception: Addressing complying with regulations in effect at the time of installation may be maintained provided that any replacement addressing shall comply with current provisions to the extent practicable as determined by the building official. E. Automatic Fire Sprinkler Systems. Section R309 is hereby amended as follows: 1. R309.1 Townhouse automatic fire sprinkler systems. The exception to Section R309.1 is hereby deleted and replaced to read: Exception: An automatic sprinkler system shall not be required where additions or alterations are made to existing townhouses that do not have an automatic sprinkler system installed except when the floor area of such additions or alterations within any two-year period exceeds 50 percent of the initial existing gross floor area and the final gross floor area exceeds 5,500 square feet. 2. R309.2 One- and two-family dwellings automatic fire sprinkler systems. The exception to Section R309.2 is hereby deleted and amended to read: Exception: An automatic sprinkler system shall not be required where additions or alterations are made to existing one- and two-family dwellings that do not have an automatic sprinkler system installed except when the floor area of such additions or alterations within any two-year period exceeds 50 percent of the initial existing gross floor area and the final gross floor area exceeds 5,500 square feet. 3. R309.3.6.2.2 Calculation procedure. The first sentence of Section R309.3.6.2.2 is hereby amended to read as follows: Section R313.3.6.2.2 Calculation procedure. Determination of the required size for water distribution piping shall be in accordance with the following procedure and California Fire Code Section 903.3.5.3: F. Fire sprinklers, attached garages and carports with habitable space above. Section R317.5.1 is hereby amended by deleting and replacing the exception to read: Exception: An automatic residential fire sprinkler system shall not be required when additions or alterations are made to existing carports and/or garages that do not have an automatic residential fire sprinkler system installed in accordance with this section unless a sprinkler system is required in accordance with California Fire Code Section 903.2.8. G. Under-Floor Space. Section R408.2 is hereby deleted and replaced to read: R408.2 Openings for under-floor ventilation. Ventilation openings through foundation or exterior walls surrounding the under-floor space shall be provided in accordance with this section. The minimum net area of ventilation openings shall be not less than 1 square foot (0.0929 m 2 ) for each 150 square feet (14 m 2 ) of under-floor area. One ventilation opening shall be within 3 feet (915 mm) of each external corner of the under-floor space. Ventilation openings shall be covered for their height and width with any of the following materials provided that the least dimension of the covering shall not exceed ⅛ inch (6.4 mm), and operational louvers are permitted: 1. Perforated sheet metal plates not less than 0.070 inch (1.8 mm) thick. 2. Expanded sheet metal plates not less than 0.047 inch (1.2 mm) thick. 3. Cast-iron grill or grating. 4. Extruded load-bearing brick vents. 5. Hardware cloth of 0.035-inch (0.89 mm) wire or heavier. 6. Corrosion-resistant wire mesh, with the least dimension not exceeding ⅛ inch (3.2 mm). Exceptions: 1. The total area of ventilation openings shall be permitted to be reduced to 1/1,500 of the under-floor area where the ground surface is covered with an approved Class I vapor retarder material. 2. Where the ground surface is covered with an approved Class 1 vapor retarder material, ventilation openings are not required to be within 3 feet (915 mm) of each external corner of the under-floor space provided that the openings are placed to provide cross ventilation of the space. H. Ventilation required. Section R806.1 is hereby deleted and replaced to read: R806.1 Ventilation required. Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow. Ventilation openings shall have a least dimension of 1/16 inch (1.6 mm) minimum and ⅛ inch (6.4 mm) maximum. Ventilation openings having a least dimension larger than 1/8 inch (6.4 mm) shall be provided with corrosion-resistant wire cloth screening, hardware cloth, perforated vinyl or similar material with openings having a least dimension of 1/16 inch (1.6 mm) minimum and ⅛ inch (6.4 mm) maximum. Openings in roof framing members shall conform to the requirements of Section R802.7. Required ventilation openings shall open directly to the outside air and shall be protected to prevent the entry of birds, rodents, snakes and other similar creatures. I. Fire Classification. Section R902 is hereby amended as follows: 1. Roof covering materials. The first paragraph of Section R902.1 is hereby deleted and replaced to read: R902.1 Roofing covering materials. Roof decks shall be covered with materials as set forth in Section R904 or with roof coverings as set forth in Section R905. A minimum Class A roofing shall be installed in areas designated by this section or where the edge of the roof deck is less than 3 feet (914 mm) from a lot line. Class A roof assemblies shall be tested in accordance with ASTM E108 or UL 790. Where required, the roof assembly shall be listed and identified as to class by an approved testing agency. Exceptions: 1. Class A roof assemblies include those with coverings of brick, masonry and exposed concrete roof deck. 2. Class A roof assemblies include ferrous or copper shingles or sheets, metal sheets and shingles, clay or concrete roof tile, or slate installed on noncombustible roof decks or ferrous, copper or metal sheets installed without a roof deck on noncombustible framing. 3. Class A roof assemblies include minimum 16 ounces per square foot (4.882 kg/m2) copper sheets installed over combustible roof decks. 4. Class A roof assemblies include slate installed over underlayment over ASTM D226, Type II underlayment over combustible decks. 2. Roof coverings in all other areas. Section R902.1.2 is hereby deleted and replaced to read: R902.1.2 Roof coverings in all other areas. The entire roof covering of every existing structure where more than 50 percent of the total roof area is replaced within any one-year period, the entire roof covering of every new structure, and any roof covering applied in the alteration, repair or replacement of the roof of every existing structure, shall be a fire-retardant roof covering that is at least Class A fire classification. J. Outdoor fireplaces, fire pits, fire rings or similar devices. Section R1001.14 is hereby added to read: R1001.14 Outdoor fireplaces, fire pits, fire rings, or similar devices. Outdoor fireplaces, fire pits, fire rings, or similar exterior devices, other than barbeques, grills, and other portable devices intended solely for cooking, shall comply with this section. R1001.14.1 Gas-fueled devices. Outdoor fireplaces, fire pits and similar devices fueled by natural gas or liquefied-petroleum gas are allowed when approved in writing by the Building Department and the device is designed to only burn a gas flame and not wood or other solid fuel. At R-3 occupancies, combustible construction shall not be located within 3 feet of an atmospheric column that extends vertically from the perimeter of the device. Where a permanent Building Department approved hood and vent is installed, combustible construction may encroach upon this column between the bottom of the hood and the vent opening. Where chimneys or vents are installed, they shall have a spark arrester in accordance with Section R1003.9.2. R1001.14.2 Devices using wood or fuels other than natural gas or liquefied-petroleum gas. Fireplaces burning wood or other solid fuel shall be constructed in accordance with Section R1001. Fires in a fireplace shall be contained within a firebox with an attached chimney. The opening in the face of the firebox shall have an installed and maintained method of arresting sparks. The burning of wood or other solid fuel in a device is not allowed within 15 feet of combustible structures, unless within a permanent or portable fireplace. R1001.14.3 Where prohibited. The burning of wood and other solid fuels shall not be conducted within a fuel modification zone. Wood and other solid fuel burning fires in devices other than permanent fireplaces are not allowed within Wildfire Risk Areas (WRA) and adopted Fire Hazard Severity Zones (FHSZ) or in locations where conditions could cause the spread of fire to the WRA or FHSZ, unless the fire code official determines that the location or design of the device should reasonably prevent the start of a wildfire. K. Automatic Vehicular Gates. Section BH103 of Appendix BH is hereby amended by adding Section BH103.3 to read: BH103.3 Vehicular gates or other barriers across required fire apparatus access roads. The installation of gates or other barriers across a required fire apparatus access road shall be approved in writing by the fire code official. Gates or barriers shall be in accordance with the City of Irvine Security Code and the Orange County Fire Authority Guideline B-09 "Fire Master Plans for Commercial and Residential Development." L. Swimming Pool Safety Act. Appendix CI of the California Residential Code is hereby amended as follows: 1. Swimming pool safety features. Section 115922 of Appendix CI is hereby deleted and replaced to read: (a) Except as provided in Section 115925, subject to subdivision (b), and consistent with Section 1596.814, when a building permit is issued for the construction of a new swimming pool or spa or the remodeling of an existing swimming pool or spa at a private single-family home, the respective swimming pool or spa shall be equipped with Item (1) below and at least one additional drowning prevention safety feature from Items (2)-(6): (1) An enclosure that meets the requirements of Section 115923 and isolates the swimming pool and spa from the private single-family home. Any walls of the residential structure or accessory structures used to complete the isolation enclosure must comply with either Section 115922 (a)(4) or (5). Any such door or window protection device provided for this purpose may not be used to comply with the second drowning prevention feature requirement. (2) Removable mesh fencing that meets the ASTM International F2286 standard in conjunction with a gate that is self-closing and self-latching and can accommodate a key lockable device. (3) A manually operated or power-operated safety pool cover that is accompanied by a label verifying that the cover meets the specifications of the ASTM International F1346-23 standard. (4) Exit alarms on the private single-family home's doors and windows that provide direct access to the swimming pool or spa without any intervening enclosure. Whenever any door or window is opened or left ajar, exit alarms shall make either an audible, continuous alarm sound or a repeating verbal warning, such as a notification that "the door to the pool is open." An exit alarm may be battery operated or connected to the electrical wiring of the building. (5) A self-closing, self-latching device with a release mechanism placed no lower than 54 inches above the floor on the private single family home's doors providing direct access to the swimming pool or spa. (6) An alarm in good repair and operable as designed that, when placed in a swimming pool or spa, will sound upon detection of accidental or unauthorized entrance into the water. The alarm shall meet and be independently certified to the ASTM International F2208 standard that includes surface motion, pressure, sonar, laser and infrared type alarms. A swimming protection alarm feature designed for individual use, including an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water, is not a qualifying drowning prevention safety feature. (7) Other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the features set forth above and has been independently verified by an approved testing laboratory as meeting standards for those features established by ASTM International, the American Society of Mechanical Engineers, or another nationally recognized standards development organization, and the feature is accompanied by a label verifying that the protection meets those standards. (b) The requirements of subdivision (a) are not satisfied by any of the following: (1) An exit alarm and a self-closing, self-latching device on the same door. (2) An exit alarm and a door latch on separate doors. (3) A safety pool cover and an alarm described in paragraph (6) of subdivision (a) (c) Before the issuance of a final approval for the completion of permitted construction or remodeling work, the building official shall inspect the drowning safety prevention features required by this section and, if no violations are found, shall give final approval. 2. Enclosure of yards containing private pools/spas. Appendix AX of the California Residential Code is hereby amended to add Section AX101 to read: AX101 Enclosure of yards containing private pools/spas. Every person in possession of land within the City, either as owner, purchaser under contract, lessee, tenant, licensee or otherwise, upon which is situated a private swimming pool or other out-of-doors body of water having a depth in excess of 18 inches that is designed, constructed and/or used for swimming, dipping or immersion by men, women or children shall maintain in good condition an enclosure to completely separate the private pool from adjoining properties by fencing complying with Health and Safety Code Section 115923 or building walls, or a combination thereof, substantially constructed, not lower than five feet in height above the surface of the ground measured vertically from the outside grade. Any pool enclosed by a fence or enclosure which does not meet the requirements of this chapter shall be drained immediately and shall not be refilled until such time as the enclosure is brought into compliance with the provisions of this article. All gates opening through the swimming pool yard enclosure shall be equipped with a self-closing and self-latching device designed to keep such door or gate securely closed at all times when not in actual use. Access gates through the enclosure shall open away from the swimming pool. The unlocking or unlatching device shall be located not less than five feet above grade or steps at the gate or door measured vertically outside the enclosed areas and shall include any passage door or gate opening from an accessory building, such as a garage. Exceptions: 1. The unlocking or unlatching device may be located on the inside of the enclosure at less than the required five feet in height when not operable from the outside of the enclosure. 2. Double-gates installed across vehicular access ways shall be self-closing and shall be equipped with a latching device which may be manually operated. Such gates shall be securely closed at all times when not in actual use.
(Ord. No. 25-26, § 5(Exh. D), 11-12-25)
Ask a question about Irvine law
Corpus searches the Irvine sections it holds and shows the ones that match, with their citations. Free, no sign-in.