Sec. 7.30.040. - Schedule "A" subdivision.
Any division of land into five (5) or more parcels, where any parcel is less than eighteen thousand (18,000) square feet in net area, shall be defined as a Schedule "A" subdivision. (1) Streets. The minimum improvements for public streets are established as follows: (a) Arterial highways: Eighty-six (86) feet in width, designed and constructed in conformance with County Ordinance No. 461, Standard No. 100. (b) Arterial (urban) highways: One hundred and ten (110) feet in width, designed and constructed in conformance with County Ordinance No. 461, Standard No. 100(A). (c) Arterial (mountain) highways: Sixty-four (64) feet in width, designed and constructed in conformance with County Ordinance No. 461, Standard No. 100(B), Section (A). A maximum width of forty (40) feet in conformance with County Ordinance No. 461, Standard No. 100(B), Section (C) may be allowed when anticipated low traffic volumes or rugged terrain does not warrant construction of a sixty-four (64) foot, four (4) lane highway. A minimum width of fifty-two (52) feet in conformance with County Ordinance No. 461, Standard No. 100(B), Section (B) may be required in steep terrain to provide for a passing lane. (d) Major highways: Seventy-six (76) feet in width, designed and constructed in conformance with County Ordinance No. 461, Standard No. 101. (e) Secondary highways: Sixty-four (64) feet in width, designed and constructed in conformance with County Ordinance No. 461, Standard No. 102. (f) Collector streets: Forty-four (44) feet in width, designed and constructed in conformance with County Ordinance No. 461, Standard No. 103, Section (A). (g) General local streets: Forty (40) feet in width, designed and constructed in conformance with County Ordinance No. 461, Standard No. 104, Section (A). (h) Short local or circulatory interior streets: Thirty-six (36) feet in width, designed and constructed in conformance with County Ordinance No. 461, Standard No. 105, Section (A). (i) Restricted local or noncirculatory interior streets: Thirty-two (32) feet in width, designed and constructed in conformance with County Ordinance No. 461, Standard No. 106, Section (A); provided, however, that in areas with an elevation of five thousand (5,000) feet or more it shall be twenty-eight (28) feet in width, designed in conformance with County Ordinance No. 461, Standard No. 112, Local Mountain Residential Street. (j) Access road: Thirty-two (32) feet in width, designed and constructed in conformance with County Ordinance No. 461, Standard No. 106, Section (B). (k) Frontage roads: Designed and constructed in conformance with County Ordinance No. 461, Standard No. 107, Section (A), 108 or 109. (l) Cul-de-sac streets: Shall be designed and constructed in conformance with County Ordinance No. 461, Standard No. 800. (m) Alleys: Twenty (20) feet in width, designed and constructed in conformance with County Ordinance No. 461, Standard No. 500. (n) Part-width streets: Shall be one-half (½) of the required improvement, but not less than twenty-eight (28) feet, designed and constructed in conformance with County Ordinance No. 461, Standard No. 110, Section (A). (o) Street name signs: Type and placement shall conform with County Ordinance No. 461, Standard No. 816. (p) Barricades: Shall be placed at the end of dead-end streets in accordance with County Ordinance No. 461, Standard No. 810. (q) Sidewalks: Shall be required to be constructed unless they are determined by the approving body to be unnecessary considering the design of the development. Sidewalk construction shall be in accordance with the improvement standards of County Ordinance No. 461. (2) Domestic water. The minimum requirement for domestic water supply and distribution system is as follows: (a) Water supply. Water shall be provided to meet the requirements as set forth in the California Administrative Code, Title 22, Chapter 16 (California Waterworks Standards). Improvement plan review shall be as required by Section 7.20.030; (b) Piped water systems. (3) Fire protection. The minimum requirement for fire protection facilities in residential zones that do not allow multifamily residential uses shall be as follows: (a) Type of fire hydrant and connection as approved by the agency providing fire protection; (b) Approved fire hydrants shall be located one (1) at each street intersection, and spaced not more than three hundred and thirty (330) feet apart in any direction; (c) The water system shall be capable of providing a fire flow of one thousand (1,000) GPM for two (2) hours duration at a minimum of twenty (20) PSI operating pressure from each fire hydrant. This amount shall be in addition to the average day demand as defined in the California Administrative Code, Title 22, Chapter 16 (California Waterworks Standards); (d) The fire protection system shall be installed and operational prior to any combustible building material being placed on the job site; (e) In zones that allow multifamily residential uses, the minimum fire protection shall be set forth in Chapter 8.10. (4) Sewage disposal. The minimum requirements for sewage disposal shall be as follows: (a) Sewage disposal shall be provided by connection to an existing collection system capable of accepting the waste load, or, if an existing collection system is not available by the development of individual subsurface sewage disposal systems that meet Health Department and the Regional Water Quality Control Board standards and requirements, or, by development of a package treatment plant that meets the Health Department and Regional Water Quality Control Board standards and requirements. (b) Improvement plans for sewage collection systems shall be reviewed as required by Section 7.20.030. (c) A dry sewer may be required as set forth in Chapter 7.45 when subsurface sewage disposal is approved. (5) Fences. Minimum fencing requirement shall be as follows: six (6) foot high chain link galvanized wire fence shall be installed along any canal, drain, expressway or other feature deemed to be hazardous. (6) Electrical and communication facilities. Minimum requirement for electrical and communication facilities shall be as follows: electrical and communication facilities shall be installed in conformity with the provisions of Chapter 7.50.
Ask a question about Jurupa Valley law
Corpus searches the Jurupa Valley sections it holds and shows the ones that match, with their citations. Free, no sign-in.