§ 7.30.070 — Schedule "D" subdivision
Municipal Code of the City of Jurupa Valley, California (Codified through Ordinance No. 2026-12, enacted October 1, 2026 (Supp. No. 28)) · Jurupa Valley Municipal Code § 7.30.070
Corpus is an independent public-information project, not the official City of Jurupa Valley website. Stable reference: corpuslaw.us/code/d975aede-af11-411c-b921-6ee2f563df08
Sec. 7.30.070. - Schedule "D" subdivision.
Any division of land into five (5) or more parcels, where any parcel is not less than five (5) acres in gross area up to twenty (20) acres in gross area, shall be defined as a Schedule "D" subdivision. The minimum improvements for a Schedule "D" subdivision shall be as follows: (1) Streets. (a) If the streets are not to be accepted for maintenance by the city, all streets shall be improved with twenty-four (24) feet of suitable aggregate base, four (4) inches thick, on a forty (40) foot graded roadway section. Vertical grades and horizontal alignments shall be held to an acceptable tolerance as determined by the Public Works Director. (b) If the streets are to be accepted for maintenance by the city, the improvements shall be the same as those required for Schedule "C" subdivisions. (2) Domestic water. The minimum requirements for a domestic water supply and distribution system are as follows: (a) No water system required. If a water system is installed, the requirements shall be as follows: (i) Water supply. Water shall be provided to meet the requirements as set forth in the California Administrative Code, Title 22, Chapter 16 (California Waterworks Standards). Improvement plan review shall be as required by Section 7.20.030; (ii) Pipe water systems. (b) If no water system is installed, the following statement shall be placed on each map sheet of the record land division map and Environmental Constraints Sheet, in letters not less than one-quarter (¼) inch high: No water system is provided for the land division as of the date of recordation of this map. (3) Fire protection. (a) If a water system is installed, the minimum requirements for fire protection facilities in single-family residential zones shall be as approved by the Fire Chief or as follows: (i) The water system shall be capable of providing a fire flow of five hundred (500) GPM for two (2) hours duration at a minimum of twenty (20) PSI operating pressure from each fire hydrant. This amount shall be in addition to the average day demand as defined in the California Administrative Code, Title 22, Chapter 16 (California Waterworks Standards). (ii) Approved fire hydrants shall be located one (1) at each street intersection, and spaced not more than six hundred and sixty (660) feet apart in any direction. (b) If a domestic water system is installed that does not meet the minimum fire protection requirements, the following statement shall be placed on each map sheet of the environmental constraints sheet in letters not less than one-quarter (¼) inch high: The domestic water system provided for this land division does not meet the minimum fire protection requirements. (4) Sewage disposal. The minimum requirements for sewage disposal shall be as follows: (a) No sewage disposal collection system is required. (b) The land divider will be required to provide the Health Department with a sewage disposal feasibility report in conformance with Health Department and the Regional Water Quality Control Board standards.
Ask a question about Jurupa Valley law
Corpus searches the Jurupa Valley sections it holds and shows the ones that match, with their citations. Free, no sign-in.
