§ 94.2010.0 — NFPA 13

Los Angeles Municipal Code (2026 Rev. 9, current through legislation effective June 30, 2026) · Los Angeles Municipal Code § 94.2010.0

Corpus is an independent public-information project, not the official City of Los Angeles website. Stable reference: corpuslaw.us/code/a20524c9-4e78-447d-92ee-c44ee939f7dc

SEC. 94.2010.0. NFPA 13.

(Amended by Ord. No. 188,797, Eff. 12/31/25.) Chapter 35 of the 2025 California Building Code to the extent it adopts and amends NFPA 13 is adopted by reference and the following Subsections are added to read as follows: 94.2010.1. Comply with the sprinkler provisions in Chapters 4 and 9 of the California Building Code as they pertain to sprinkler systems. 94.2010.2. NFPA 13 Section 3.3.252 is added to read as follows: 3.3.252. Water Curtain is a line of closely spaced fire sprinklers (or a single sprinkler) aligned adjacent to openings to keep fire from penetrating those openings. 94.2010.3. NFPA 13 Section 9.3.5.5 is added to read as follows: 9.3.5.5. Water curtains shall consist of closely spaced sprinklers and draft stops that are made of noncombustible or limited combustible material. The draft stops shall be located immediately adjacent to the opening and shall be at least 18 inches (47.2 mm) deep measured from the sprinkler deflector to the bottom of the draft stop and shall be of noncombustible or limited-combustible material. Sprinklers shall be spaced not more than 6 feet (1929.8 mm) apart and placed 6 to 12 inches (152.4 mm to 304.8 mm) from the draft stop on the side away from the opening. Where sprinklers are closer than 6 feet (1828.8 mm), cross baffles shall be provided in accordance with NFPA 13 Section 10.2.6.4.2. 94.2010.4. NFPA 13 Section 16.9.10.5 is added to read as follows: Locations. Floor control valves shall be within a stairway enclosure or within the vestibule or on the access balcony of a smoke proof enclosure. EXCEPTIONS: 1. In buildings with three or fewer stories or where there is no stairway that serves a floor, control valves may be located elsewhere on the floor level. 2. Unenclosed stairways in parking garages. 94.2010.5. NFPA 13 Section 19.3.3.6 is added to read as follows: 19.3.3.6. Water curtains shall be hydraulically calculated in accordance with NFPA 13 Section 19.3.

Ask a question about Los Angeles law

Corpus searches the Los Angeles sections it holds and shows the ones that match, with their citations. Free, no sign-in.