§ 9.166.045: Mandatory location/design requirements and regulations for all facilities.

Each of the proposed power supply facilities shall comply with all of the following requirements: A. Any power supply facility that is located above ground on a flat landscaped area shall be enclosed in a cabinet that is screened from view on at least three sides by a berm, a wall and/or landscaping in a manner approved by the Director and, if located in the public right-of-way, by the Director of Public Works. For the purposes of this section, a "berm" shall mean an earthen slope from the highest point of the facility to the existing grade; B. No power supply facility shall be located in either of the following locations anywhere within the City: 1. On a public or private sidewalk in such a way that the power supply facility restricts pedestrian access as determined by the City; or 2. On a public or private parkway between the curb and sidewalk. C. Except for necessary gas meters, any and all accessory lines and equipment attached or appurtenant to the power supply facility, or other equipment associated with the operation of the power supply facility, shall be located within a building, enclosure, underground vault, or otherwise undergrounded in a manner that complies with the development standards of the zoning district in which such equipment is located; D. The power supply facility shall be located to ensure adequate sight distance is provided per City standards in accordance with Standard Plans 1117 as adopted by the City of Lake Forest pursuant to Chapter 14.20 of this Code, and to the satisfaction of the Director of Public Works; E. The maximum height of any new power supply facility shall not exceed 48 inches in height above existing grade measured from the highest point of the existing grade immediately adjacent to the facility; F. Any portion of cabinet enclosing the power supply facility which is located above ground shall be painted in a matte finish or camouflaged to blend with the surrounding environment as approved by the Director and, if located within the public right-of-way, by the Director of Public Works; G. Any portion of cabinet enclosing the power supply facility which is located above ground shall be covered with a clear anti-graffiti material of a type approved by the Director, and, if located within the public right-of-way, by the Director of Public Works; H. Any removal of landscaping to install the power supply facility shall be replaced with landscaping of a similar type and size as approved by the Director, and, if located within the public right-of-way, by the Director of Public Works; I. The power supply facility shall not bear any signs or advertising devices (other than certification, warning or other required seals or required signage); J. The power supply facility shall comply with all conditions set forth in the site development permit and/or encroachment permit, if applicable; K. The power supply facility shall comply with the requirements for undergrounding for the zone in which the power supply facility is located; L. The power supply facility shall at all times meet the City's adopted noise standards for the zone in which it is located; M. The power supply facility shall be located a minimum of 20 feet from the closest principal residential structure.

( Ord. 176 § 1, 2007 )

Ask a question about Lake Forest law

Corpus searches the Lake Forest sections it holds and shows the ones that match, with their citations. Free, no sign-in.