§ 18.69.030 — Structural weaknesses
Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 18.69.030
Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/fd887c59-0b56-46c5-9464-4c37937aaf9a
18.69.030 - Structural weaknesses.
A. Sill plates or floor framing which are supported directly on the ground without an approved foundation system. B. A perimeter foundation system which is constructed of wood posts supported on isolated pad footings. C. Perimeter foundation systems that are not continuous. EXCEPTIONS: 1. Existing single-story exterior walls not exceeding ten (10) feet in length forming an extension of floor area beyond the line of an existing continuous perimeter foundation. 2. Porches, storage rooms and similar spaces not containing fuel burning appliances. D. A perimeter foundation system which is constructed of unreinforced masonry. E. Sill plates which are not connected to the foundation or are connected with less than what is required by Subsection 18.69.040.C.1. F. Cripple walls that are not braced in accordance with the requirements of Subsection 18.69.040.D and Table 69-A.
(ORD-25-0019 § 1(Exh. A), 2025; ORD-22-0033 § 1(Exh. A), 2022; ORD-19-0031 § 1(Exh. A), 2019; ORD-16-0026 § 1(Exh. A), 2016)
Ask a question about Long Beach law
Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.
