§ 18.69.050 — Quality control
Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 18.69.050
Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/e6116e43-361e-41b9-9ad4-61712a03140d
18.69.050 - Quality control.
A. Inspection by the Department. All work shall be subject to inspection by the Building Official including, but not limited to: 1. Placement and installation of new adhesive or expansion anchors or anchor side plates installed in existing foundations; 2. Placement of required blocking and framing anchors; 3. Installation and nailing of new cripple wall bracing. The torque testing of sill plate anchors per Subsection 18.69.040.C.1 shall be performed by the Building Inspector. B. Special inspection. Special inspection is not required for sill plate anchors installed in existing foundations regulated by the provisions of this chapter. Any work may be subject to special inspection when required by the Building Official or when so designated by the registered design professional of record. C. Structural observation. Structural observation is not required for work done under the prescriptive provisions of this chapter. When construction documents for strengthening are prepared by a registered design professional and alternate materials or methods are used, structural observation shall be provided as required in Section 1704.6 of the California Building Code adopted in Chapter 18.40. D. Registered design professional of record's statement. When an alternative design is provided per Subsection 18.69.010.C, the responsible registered design professional of record shall place the following statement on the approved construction document: 1. "I am responsible for this building's seismic strengthening design for the under floor cripple walls and sill bolting in compliance with the minimum seismic resistance standards of Chapter 18.69 of the Long Beach Municipal Code." or when applicable: 2. "The registered special inspector, required as a condition of the use of structural design stresses requiring continuous inspection, will be responsible to me." TABLE 69-A SILL PLATE ANCHORAGE AND CRIPPLE WALL BRACING 1,2,3 Number of Stories Above Cripple Walls | Minimum Sill Plate Connection and Maximum Spacing | Amount of Wall Bracing One Story | Adhesive or expansion anchors shall be ½ inch minimum diameter spaced at 6 feet maximum center to center. | Each end and not less than 50% of the wall length. Two Story | Adhesive or expansion anchors shall be ½ inch minimum diameter spaced at 4 feet maximum center to center; or ⅝ inch spaced at 6 feet maximum center to center. | Each end and not less than 70% of the wall length. Three Story | Adhesive or expansion anchors shall be ½ inch minimum diameter spaced at 2 feet 8 inches maximum center to center; or ⅝ inch minimum diameter spaced at 4 feet maximum center to center. | 100% of the wall length.
(ORD-25-0019 § 1(Exh. A), 2025; ORD-22-0033 § 1(Exh. A), 2022; ORD-16-0026 § 1(Exh. A), 2016)
Ask a question about Long Beach law
Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.