§ 15.04.3.2085 — CBC Section 2308.3.1 amended

Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Municipal Code § 15.04.3.2085

Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/900323e4-191e-41ca-9a57-6ab78ce50c8b

15.04.3.2085 - CBC Section 2308.3.1 amended.

In Section 2308.7.1 of the California Building Code: A. In the second sentence beginning with "Foundation plates or sills…", replace "V-inch diameter (12.7 mm) steel bolts" with "⅝"-inch diameter (15.9 mm) steel bolts." B. In the fourth sentence beginning with "Bolts shall be spaced…", replace "6 feet (1829mm) on center" with "4 feet (1219mm) on center, and adequately secured in-place by an approved method before placement of concrete or grout…."

(Ord. No. 13861, § 4, 9-15-2025)