§ 15.04.3.25055 — CRC Section R403.1.6 amended

Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Municipal Code § 15.04.3.25055

Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/50598de8-ffe4-4430-b9eb-93d73c58da68

15.04.3.25055 - CRC Section R403.1.6 amended.

In Section R403.1.6 of the California Residential Code, replace the first sentence of the third paragraph starting with "Wood sole plates…" with the following: "Wood sole plates at all exterior walls on monolithic slabs, wood sole plates of braced wall panels at building interiors on monolithic slabs and all wood sill plates shall be anchored to the foundation with minimum ⅝-inch-diameter (15.9 mm) anchor bolts spaced not greater than 4 feet (1219 mm) on center or approved anchors or anchor straps spaced as required to provide equivalent anchorage to ⅝-inch-diameter (15.9 mm) anchor bolts."

(Ord. No. 13861, § 4, 9-15-2025)