For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.04.3.25115 — CRC R506.3.3 amended

Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Municipal Code § 15.04.3.25115

Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/22f28863-0155-4896-b2b0-f1d26452c83b

15.04.3.25115 - CRC R506.3.3 amended.

Add after the first sentence: "The use of topically applied moisture barriers to concrete slabs in conjunction with conversion of non-habitable spaces to habitable spaces provided the following are adhered to: a) The product's permeability is at most 0.09 perms for vapor transmission toward the habitable space, as tested according with ASTM E96, which is equivalent or better than that of 6-mil polyethylene (as tested with ASTM E1745). b) Technical documentation, supplied by the manufacturer, based on accredited independent laboratory testing, is provided clearly indicating the product's performance meet these criteria. c) The product is installed per its listing by qualified individuals and per the manufacturer's instructions and special inspection is conducted by a person knowledgeable and with demonstrated history of performing such inspections on the applications of such product. d) The owner agrees to hold the City of Oakland Harmless by completing and submitting a Hold armless Agreement to be filed with the County Recorder against the parcel for a fee in accordance with the Oakland Master Fee Schedule."

(Ord. No. 13861, § 4, 9-15-2025)

Ask a question about Oakland law

Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.