Sec. 29.105. - Distribution boxes.

Any distribution box hereafter constructed or installed in the city shall meet the following minimum specifications: Tightness, material. Such distribution box shall be watertight and shall be constructed of the same materials authorized for the construction of a septic tank. Elevation of outlets. The outlets from such distribution box shall have exactly the same elevation. Elevation of inlet. The inlet to such distribution box shall be one inch above the elevation of the outlets. Tile system. Each distribution box shall be connected to a subsurface tile system consisting of at least two (2) lateral absorption lines. Cesspool for absorption line. One or more cesspools may be substituted for or used in conjunction with lateral absorption lines when approved by the director. Joints in lines. All lines leading from the distribution box to the lateral absorption lines or to cesspools shall be constructed with watertight joints.

(Ord. Code, §§ 8454 to 8454.4)