For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 29.106 — Subsurface tile systems

The Code of the City of Oceanside, California (Supp. No. 50: codified through Ordinance No. 26-OR0412-1, enacted June 17, 2026) · Oceanside City Code § 29.106

Corpus is an independent public-information project, not the official City of Oceanside website. Stable reference: corpuslaw.us/code/3a411069-5652-400b-9dd6-43e1e2c58c53

Sec. 29.106. - Subsurface tile systems.

Any subsurface tile system hereafter constructed or installed in the city for the purpose of disposing of the effluent from a septic tank shall meet the following minimum specifications: Number, length of lines. Such tile system shall consist of at least two (2) lateral absorption lines totaling at least two hundred (200) feet in length. Maximum length. Provided, however, each line shall not exceed one hundred twenty-five (125) feet in length. Standard length of lines. Where it is practical, each line shall be one hundred twenty-five (125) feet in length. Open joints. Lateral absorption lines shall be constructed of tile pipe spaced one-quarter (¼) inch apart so as to provide open joints. Tar paper or screen. The upper one-half (½) of each open joint shall be covered with tar paper or copper screen. Trench, gravel. Each lateral absorption line shall be placed in a trench at least eighteen (18) inches wide, which trench shall contain at least thirteen (13) inches of rock or gravel grading not less than one inch, with at least four (4) inches of such rock or gravel beneath the bottom of the line and four (4) inches of such rock or gravel over the top of the line. Grade. Lateral absorption lines shall have a grade of two (2) inches per one hundred (100) feet with not more than fifty (50) percent variation either way. Depth. Lateral absorption lines shall not be more than thirty (30) inches below the surface of the ground. Distance between lines. Every lateral absorption line shall be at least ten (10) feet from every other lateral absorption line. Ells and wyes. Where it is necessary to use ells or wyes on any lateral absorption line, at least ten (10) feet of closed-joint tile shall be inserted at each such fitting so as to space the absorption lines at least ten (10) feet apart.

(Ord. Code, §§ 8455 to 8455.61)

Ask a question about Oceanside law

Corpus searches the Oceanside sections it holds and shows the ones that match, with their citations. Free, no sign-in.