Sec. 6-7.404. Interceptors.
(a) A food service establishment discharging grease wastes which, under the conditions existing in the downstream sewers, could cause or threaten to cause stoppage or grease accumulations, shall install an approved grease and oil interceptor and regularly maintain it so as to prevent excessive discharges of grease and oil into the sewerage system. The costs of installing and maintaining such device(s) shall be at the sole expense of the user. Any user who operates, owns or maintains a food service establishment shall cause all floor drains, floor sinks, sinks, and waste container wash racks to be directed through the grease and oil interceptor, and shall keep all domestic wastewater from restrooms, showers, drinking fountains, and condensate (i.e. ice melt, air conditioning) separate from the food service wastewater until the food service wastewater has passed through all necessary pretreatment equipment, devices, or monitoring stations. (b) Each permittee shall be required to provide a collection tank or container for the purpose of physically segregating oils, greases, and greasy solids from wash water. Permittees shall establish procedures for personnel to follow in order to segregate oils, greases, and greasy solids to the collection container prior to performing any washing and other water cleaning which goes into the sewers. The permittee shall be responsible for the proper removal and lawful disposal of the material captured from either the grease pretreatment devices on wastewater lines or the collection container utilized for the segregation of oils, greases and greasy solids. (c) Each vehicle wash, vehicle or equipment servicing, industrial transportation, and/or cleaning facility shall install an appropriate sand, grease and oil Interceptor of a size and design approved by the Administrator. Wastewater arising from the cleaning, servicing and repair of vehicles shall pass through this interceptor before discharge to the sewerage system. (d) If an interceptor is not adequate under the conditions of use, one which is effective in accomplishing the intended purpose shall be constructed by the user within a time period established by the Administrator. (e) The design plans for any required interceptor not included in the Plumbing Code or City standard drawings shall be prepared and signed by an engineer registered in the State of California and meet the drawing submittal requirements set forth in § 6-7.401. Such plans shall be reviewed and must be approved by the Administrator prior to any construction of said device. (f) The interceptor required by this chapter shall be watertight, structurally sound, durable, properly maintained, and easily accessible for inspection and cleaning to assure that the accumulation of sand, oil or grease does not impair the efficiency of the interceptor or pass through the device. At no time shall any material, debris, obstacle or obstruction be placed in such a manner as to prevent immediate access to the Interceptor. (g) A user who is required to install and maintain an interceptor shall keep maintenance records and hauler's manifests for a minimum of three (3) years. These records shall be made available to the Administrator upon request. Each vehicle wash and food service facility shall be responsible for the costs of installing, inspecting, pumping, cleaning and maintaining its grease interceptor. Cleaning and maintenance must be performed when the total volume of captured grease and solid material displaces more than twenty percent (20%) of the total volume of the unit. All vehicle wash and food service facilities that have grease interceptors shall utilize a licensed grease hauler who has been permitted for pumping services. Pumping services shall include the initial complete removal of all contents, including floating materials, wastewater and bottom sludge and solids from the interceptor. It is unlawful for any grease waste hauler to reinsert, deposit, pump, place, release, or discharge into a grease trap, grease interceptor, manhole, cleanout, or other sanitary sewer appurtenance any materials that the hauler has removed from the grease trap or grease interceptor, or to cause those materials to be so handled. This prohibition as it pertains to the reinsertion of material removed from a grease trap or grease interceptor, shall not apply to a grease waste hauler that has met all of the conditions that are outlined in both the California Penal Code Section 374.5(a)(2)(b) and the City of Ontario Public Sewer System Ordinance, Title 6, Chapter 7, § 6-7.404. Grease interceptor cleaning shall include scraping excessive solids from the walls, floors, baffles and all pipe work. It shall be the responsibility of each vehicle wash or food service facility to inspect its grease interceptor during the pumping procedure to ensure that the interceptor is properly cleaned out and that all fittings and fixtures inside the interceptor are in working condition and functioning properly. (h) Each vehicle wash or food service facility shall determine the frequency at which its grease interceptor(s) shall be pumped according to the following criteria: (1) When the floatable grease layer exceeds six (6) inches in depth as measured by an approved dipping method; (2) When the settleable solids layer exceeds eight (8) inches in depth as measured by an approved dipping method; (3) When the total volume of captured grease and solid material displaces more than twenty percent (20%) of the capacity of the interceptor as calculated using an approved dipping method; or (4) When the interceptor is not retaining/ capturing oils and greases; or the removal efficiency of the device, as determined through sampling and analysis, is less than eighty percent (80%). (i) Periodic inspection of the interceptor may be performed to determine compliance with this section. The owner and/or user of the property shall be subject to enforcement actions if such user fails to maintain the interceptor and/or keep adequate records. (j) Conditional waivers for the grease and oil interceptor or sand, grease and oil interceptor requirement shall be granted by the Administrator for food service establishments or vehicle wash, vehicle or equipment servicing, industrial transportation and/or cleaning facility determined not to have adverse effects on the City's sewerage system or the POTW. Conditional waivers may be revoked for the following reasons: (1) Changes in menu; (2) Falsification of information submitted; (3) Change in operating hours; (4) Changes in equipment used; (5) Changes in the number of vehicles washed; or (6) As determined by the Administrator to have adverse effects on the City's sewerage system or the POTW. (k) The shared use of a grease interceptor by multiple FSEs and/or other industrial users is prohibited unless authorization is granted by the Administrator. (§ 3, Ord. 2755, eff. April 4, 2002, as amended by § 4, Ord. 2806, eff. January 21, 2005, § 5, Ord. 2945, eff. January 6, 2012, and § 2, Ord. 3190, eff. October 7, 2021)
Ask a question about Ontario law
Corpus searches the Ontario sections it holds and shows the ones that match, with their citations. Free, no sign-in.