§ 8-18.060 — Engineering analysis required
City of Ontario, California, Municipal Code (2026 S-32: Current through Ordinance 3338, passed 7-21-2026) · Ontario Municipal Code § 8-18.060
Corpus is an independent public-information project, not the official City of Ontario website. Stable reference: corpuslaw.us/code/d030f701-cd54-4214-947b-c3c218cac794
Sec. 8-18.060. Engineering analysis required.
(a) General. Engineering plans, calculations and specifications shall be filed with the applicable building permit demonstrating that the proposed retrofit work will comply with the applicable standards specified in the CBC for the buildings. (b) Mandatory seismic retrofitting. All unreinforced masonry buildings shall be retrofitted in accordance with the seismic standards contained in the CBC, except that qualified historical buildings may use the applicable provisions of the State Historical Building Code in conjunction with the CBC as provided in division (h). All destructive materials testing in accordance with the CBC is required only when those elements are used as part of the structural design. The decision of whether to test existing materials is the responsibility of the engineer/architect, and the city assumes no liability for damage, injury, or harm caused by the testing. In the absence of acceptable test data, the engineer/architect shall use allowable stresses for existing materials in accordance with the CBC or as approved by the Building Official. The owner shall file with the Building Official plans, structural calculations and specifications with an acceptable building permit application to comply with the applicable mandatory retrofit standard within the time specified in division (e). The information required for a building permit application shall be in accordance with division (f). (c) Preparer of plans, calculations and specifications. Building owners shall employ a civil or structural engineer or architect, registered by the State of California, herein called "engineer/architect", to prepare the required engineering plans, calculations and specifications acceptable to the Building Official. (d) "Scope of work", provided on the title page needs to address all the proposed work that per the Building Codes requires a permit. (e) "Building data analysis", provided on the title page needs to provide the following: (1) Codes used; (2) Building information; (3) Site information; (4) Parking requirements and provided; (5) Number of bathrooms and fixtures needed and provided; and (6) Exits, what is required, what is provided and distance to them. (f) Exception. One URM wall or common URM wall with an existing engineering analysis report on file and prepared since October 2022 shall only be required to retrofit that one URM wall or common URM wall if the owner demonstrates to the satisfaction of the Building Official that the retrofit of the common URM wall or URM wall will not weaken the remaining building and/or structure, and any other requirements that the Building Official may deem necessary to comply with this chapter. (§ 2, Ord. 3324, eff. February 19, 2026)
Ask a question about Ontario law
Corpus searches the Ontario sections it holds and shows the ones that match, with their citations. Free, no sign-in.
