For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.52.080 — Special Building Provisions—Residential

Municipal Code, City of Orange, California (through Ord. No. 01-26 adopted January 27, 2026) · Orange Municipal Code § 15.52.080

Corpus is an independent public-information project, not the official City of Orange website. Stable reference: corpuslaw.us/code/2f78ec23-c247-4e62-8ad2-b28b24434f80

§ 15.52.080: Special Building Provisions—Residential.

A. Except for vehicular access doors, all exterior swinging doors of any residential building and attached garages, including the door leading from the garage area into the dwelling unit shall be equipped as follows: 1. All wood doors shall be of solid core construction with a minimum thickness of one and three-quarter inches, or with panels not less than 9/16 inch thick. Hollow steel doors shall be of a minimum 18 U.S. gauge and have sufficient reinforcement to maintain the designed thickness of the door when any locking device is installed; such reinforcement being able to restrict collapsing of the door around any locking device. 2. A single or double door shall be equipped with a single cylinder deadbolt lock. The bolt shall have a minimum projection of one inch and be constructed so as to repel cutting tool attack. The deadbolt shall have an embedment of at least three-quarter inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five pin tumblers, and shall be connected to the inner portion of the lock by connecting screws of at least one-quarter inch in diameter. A dual locking mechanism constructed so that both deadbolt and latch can be retracted by a single action of the inside door knob, or lever, may be substituted, provided it meets all other specifications for locking devices. 3. The inactive leaf of double door(s) shall be equipped with metal flush bolts having a minimum embedment of five-eighths inch into the head and threshold of the door frame. 4. Glazing in exterior doors or within 12 inches of any locking mechanism shall be of fully tempered glass or rated burglary resistant glazing. 5. Except where clear vision panels are installed, all front exterior doors shall be equipped with a minimum 180 degrees wide angle door viewer, not to be mounted more than 58 inches from the bottom of the door. 6. All multiple-family dwelling common area storage room doors shall be equipped as outlined in Section 15.52.050 and subsections (A)(1) to (A)(4) in Section 15.52.080 of this code. B. Street numbers and other identifying data shall be displayed as follows: 1. All residential dwellings shall display a street number in a prominent location on the street side of the residence in such a position that the number is easily visible to approaching emergency vehicles. The numerals shall be no less than four inches in height and shall be of a contrasting color to the background to which they are attached. Single family dwellings shall have these numerals illuminated during the hours of darkness. 2. There shall be positioned at each entrance of a multiple-family dwelling complex an illuminated diagrammatic representation of the complex which shows the location of the viewer and the unit designations within the complex. In addition, each individual unit within the complex shall display a prominent identification number, not less than four inches in height, which is easily visible to approaching vehicular and/or pedestrian traffic. C. Lighting in multiple family-dwellings shall be as follows: 1. Aisles, passageways and recesses related to and within the building complex shall be illuminated with an intensity of at least 0.51 foot-candles at the ground level during the hours of darkness. Lighting devices shall be protected by weather and vandalism resistant covers. 2. Open parking lots and carports shall be provided with a maintained minimum of one foot-candle of light on the parking surface during the hours of darkness. Lighting devices shall be protected by weather and vandalism resistant covers. 3. Parking garages, underground walkways and any covered areas shall be provided with a minimum maintained three to five foot-candles of light on the parking surface. Lighting devices shall be protected by weather and vandalism resistant covers. If necessary, additional criterion may be required by the enforcing authority to exceed IESNA standards. D. Garages or any parking areas required to be covered, shall have vehicular access door(s) which conform to the provisions of this chapter. EXCEPTION: A vehicular access door will not be required when the inside of the garage, including the entire rear wall, is visible from floor level to a height of five feet. Visibility shall constitute an unobscured line of vision, not to exceed 80 feet, from the window of a dwelling unit to the inside of the garage. This window is to have a clear vision panel with the dimensions not less than three feet either horizontally or vertically, and the window sill to be not more than four feet from the floor. The visibility factor shall apply to those garages and windows of the same multiple family dwelling complex.

( Prior code 8714 ; Ord. 7-79 ; Ord. 06-18 , 2018 ; Ord. 06-22 , 2022 )

Ask a question about Orange law

Corpus searches the Orange sections it holds and shows the ones that match, with their citations. Free, no sign-in.