§ 15.52.090 — Special Building Provisions—Nonresidential
Municipal Code, City of Orange, California (through Ord. No. 01-26 adopted January 27, 2026) · Orange Municipal Code § 15.52.090
Corpus is an independent public-information project, not the official City of Orange website. Stable reference: corpuslaw.us/code/8fd87fac-613f-4472-a12a-b087897c0fe9
§ 15.52.090: Special Building Provisions—Nonresidential.
A. Swinging exterior glass doors, wood or metal doors with glass panels, solid wood or metal doors shall be constructed or protected as follows: 1. Wood doors shall be of solid core construction with a minimum thickness of one and three-quarter inches. Wood panel doors with panels less than one inch thick shall be covered on the inside with minimum 16 U.S. gauge sheet steel, or its equivalent, which is to be attached with screws on minimum six-inch centers. Hollow steel doors shall be of a minimum 16 U.S. gauge and have sufficient reinforcement to maintain the designed thickness of the door when any locking device is installed; such reinforcement being able to restrict collapsing of the door around any locking device. 2. Except when double cylinder deadbolts are utilized, glazing in exterior doors or within 48 inches of any door-locking mechanism shall be constructed or protected as follows: a. Fully tempered glass or rated burglary resistant glazing; or b. Iron or steel grills of at least one-eighth inch material with a minimum two-inch mesh secured on the inside of the glazing may be utilized; or c. The glazing shall be covered with iron bars of at least one-half inch round or one inch by one-quarter inch flat steel material, spaced not more than five inches apart, secured on the inside of the glazing; d. Subsections b and c above shall not interfere with the operation of opening windows if such windows are required to be openable by the current building code. B. All swinging exterior wood and steel doors shall be equipped as follows: 1. A single or double door shall be equipped with a single or double cylinder deadbolt. The bolt shall have a minimum projection of one inch and be constructed so as to repel cutting tool attack. The deadbolt shall have an embedment of at least three-quarter inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five pin tumblers, and shall be connected to the inner portion of the lock by connecting screws of at least one-quarter inch in diameter. The provisions of the preceding paragraph do not apply where: a. Panic hardware is required; or b. An equivalent device is approved by the enforcing authority; c. A magnetic (MAG) lock may be used if the minimum pulling force is 1,600 pounds. 2. Double doors shall be equipped as follows: a. The inactive leaf of double door(s) shall be equipped with metal flush bolts having a minimum embedment of five-eighth inch into the head and threshold of the door frame. b. Double doors shall have an astragal constructed of steel a minimum of 0.125 inch thick which will cover the opening between the doors. The astragal shall be a minimum of two inches wide, and extend a minimum of one inch beyond the edge of the door to which it is attached. The astragal shall be attached to the outside of the active door by means of welding or with non-removable bolts spaced apart on not more than 10-inch centers. The door to which such an astragal is attached must be determined by the current building code adopted by the enforcing authority. 3. Every single or double exterior door equipped with lever-handled locking mechanism hardware shall have an approved handicapped-accessible threshold complying with provisions of Title 24 of the current Building Code (as amended) beneath the door. The opening between the threshold and the door shall be secured in a manner approved by the Crime Prevention Bureau of the Orange Police Department designed to prevent the passing of rigid materials or mechanical devices between the door and the threshold for the purposes of unlocking the door from the interior side. C. Aluminum frame swinging doors shall be equipped as follows: 1. The jamb on all aluminum frame swinging doors shall be so constructed or protected to withstand 1,600 pounds of pressure in both a vertical distance of three inches and a horizontal distance of one inch each side of the strike, so as to prevent violation of the strike. 2. A single or double door shall be equipped with a single or double cylinder deadbolt with a bolt projection exceeding one inch, or a hook shaped or expanding dog bolt that engages the strike sufficiently to prevent spreading. The deadbolt lock shall have a minimum of five pin tumblers and a solid steel cylinder guard. D. Panic hardware, whenever required by the current Building Code standards enforced by the City of Orange and/or California Code of Regulations Title 19, California Administrative Code, shall be installed as follows: 1. Panic hardware shall contain a minimum of two locking points on each door; or 2. On single doors, panic hardware may have one locking point which is not to be located at either the top or bottom rails of the door frame. The door shall have an astragal constructed of steel 0.125 inch thick which shall be attached with non-removable bolts to the outside of the door. The astragal shall extend a minimum of six inches vertically above and below the latch of the panic hardware. The astragal shall be a minimum of two inches wide and extend a minimum of one inch beyond the edge of the door to which it is attached. 3. Double doors containing panic hardware shall have an astragal attached to the doors at their meeting point which will close the opening between them, but not interfere with the operation of either door. E. Horizontal sliding doors shall be equipped with a metal guide track at top and bottom and a cylinder lock and/or padlock with a hardened steel shackle which locks at both heel and toe, and a minimum five pin tumbler operation with non-removable key when in an unlocked position. The bottom track shall be so designed that the door cannot be lifted from the track when the door is in a locked position. F. In office buildings (multiple occupancy), all entrance doors to individual office suites shall meet the construction and locking requirements for exterior doors. Interior walls dividing the individual suites shall not end at the false ceiling but shall continue to the real roof. Access control systems (card readers) shall be subject to the same security requirements as individual office suites. G. Windows shall be deemed accessible if less than 12 feet above ground. Accessible windows and all exterior transoms having a pane exceeding 96 square inches in an area with the smallest dimension exceeding six inches and not visible from a public or private vehicular access way shall be protected in the following manner: 1. Fully tempered glass or burglary resistant glazing; or 2. The following window barriers may be used but shall be secured with non-removable bolts: a. Inside or outside iron bars of at least one-half inch round or one inch by one-quarter inch flat steel material, spaced not more than five inches apart and securely fastened; or b. Inside or outside iron or steel grills of at least one-eighth inch material with not more than a two-inch mesh and securely fastened. 3. If a side or rear window is of the type that can be opened, it shall, where applicable, be secured on the inside with either a slide bar, bolt, crossbar, auxiliary locking device, and/or padlock with hardened steel shackle, a minimum four pin tumbler operation. 4. The protective bars or grills shall not interfere with the operation of opening windows if such windows are required to be openable by the current Building Code. H. Roof openings shall be equipped as follows: 1. All skylights on the roof of any building or premises used for business purposes shall be provided with: a. Rated burglary resistant glazing and skylight secured to roof using non-removable screws; or b. Iron bars of at least one-half inch round or one inch by one-quarter inch flat steel material spaced no more than five inches apart under the skylight and securely fastened; or c. A steel grill of at least one-eighth inch material with a maximum two-inch mesh under the skylight and securely fastened. 2. All hatchway openings on the roof of any building or premises used for business purposes shall be secured as follows: a. If the hatchway is of wooden material, it shall be covered on the inside with at least 16 U.S. gauge sheet metal, or its equivalent, attached with screws. b. The hatchway shall be secured from the inside with a slide bar or slide bolts. c. Outside hinges on all hatchway openings shall be provided with non-removable pins when using pin-type hinges. 3. All air duct or air vent openings exceeding 96 square inches on the roof or exterior walls of any building or premises used for business purposes shall be secured with non-removable screws and by covering the same with either (a) or (b), and (c) and (d) as follows: a. Iron bars of at least one-half inch round or one inch by one-quarter inch flat steel material spaced no more than five inches apart and securely fastened; or b. Iron or steel grills of at least one-eighth inch material with a maximum two-inch mesh and securely fastened. c. Iron or steel louvers shall be a minimum of 12 US gauge metal. d. The above (a, b, and c) must not interfere with venting requirements creating a potentially hazardous condition to health and safety or conflict with the provisions of the current Building Code standards enforced by the City of Orange and/or Title 19 of the California Code of Regulations. I. Permanently affixed ladders leading to roofs shall be fully enclosed with sheet metal to a height of 10 feet. This covering shall be locked against the ladder with a case-hardened hasp, secured with non-removable screws or bolts. Hinges on the cover will be provided with non-removable pins when using pin-type hinges. If a padlock is used, it shall have a hardened steel shackle, locking at both heel and toe, and a minimum five-pin tumbler operation with non-removable key when in an unlocked position. J. The following standards shall apply to lighting, address identification and parking areas: 1. The address number of every commercial building shall be illuminated during the hours of darkness so that it shall be easily visible from the street. The numerals in these numbers shall be no less than eight inches in height and be of a color contrasting to the background. In addition, any business which affords vehicular access to the rear through any driveway, alleyway or parking lot shall also display the same numbers on the rear of the building. 2. Phone numbers may not be displayed upon a sign (or a building), in order to avoid confusion and minimize clutter (subsection 17.36.060(A)(1)(b)). 3. All exterior commercial doors, during the hours of darkness, shall be illuminated with a minimum of one foot candle of light. The light fixture shall be mounted on the exterior of the building, and all exterior bulbs shall be protected by weather and vandalism resistant cover(s). 4. Open parking lots, and access thereto, providing more than 10 parking spaces and for use by the general public, shall be provided with a maintained minimum of one foot candle of light on the parking surface from dusk until the termination of business every operating day. 5. Open parking lots or parking garages used exclusively for storage of vehicles shall be provided by a maintained minimum of 0.75 foot-candles of light on the parking surface from dusk until termination of business every operating day. Lighting devices shall be protected by weather and vandalism resistant covers. 6. Parking garages, underground walkways and any covered areas for use by the general public shall be provided with a minimum maintained three to five foot-candles of light on the parking surface. Lighting devices shall be protected by weather and vandalism resistant covers. If necessary, additional criterion may be required by the enforcing authority to exceed IESNA minimum standards. K. Elevators. 1. Passenger elevators, the interiors of which are not completely visible when the car door(s) is open, shall have mirrors so placed as to make visible the whole of the elevator interior to prospective passengers outside the elevator; mirrors shall be framed and mounted to minimize the possibility of their accidentally falling or shattering. 2. Elevator emergency stop button shall be so installed and connected as to activate the elevator alarm.
( Prior code 8715 ; Ord. 7-79 ; Ord. 17-89 ; Ord. 06-18 , 2018 ; Ord. 06-22 , 2022 )
Ask a question about Orange law
Corpus searches the Orange sections it holds and shows the ones that match, with their citations. Free, no sign-in.