17.37.070 - Scale Standards

These standards are intended to: • Implement the General Plan density (du/ac) and floor area ratio (FAR) values; • Shape development in a manner that creates a defined public realm and appropriate scale of buildings for a visually appealing community; • Reduce building massing through setback and stepback requirements that create appropriate transitions to residential neighborhoods; • Support high-quality architecture and urban design through modulation requirements and variation in façade length; and • Require appropriate transitions to designated historic resources. A. Density. 1. Residential Density. Projects that include residential dwelling units shall not exceed the allowable dwelling units per acre (du/ac) per Figure LASP-5. a. Fractions shall be rounded to the nearest whole number; those at 0.50 shall be rounded up. b. For projects utilizing state density bonus, refer to Government Code 65915. c. The maximum is based on total site area. If a street dedication or easement is required, density shall be calculated using the size of the lot prior to the street dedication or easement. B. Intensity. 1. Floor Area Ratio. Projects that include non-residential space, including mixed-use, shall not exceed the allowable floor area ratio (FAR) per Figure LASP-6. a. In mixed-use projects, residential floor area is included in FAR. b. Areas used exclusively for vehicle and bicycle parking and loading are excluded from FAR. c. The maximum is based on total site area. If a street dedication or easement is required, FAR shall be calculated using the size of the lot prior to the street dedication or easement. Figure LASP-5: Residential Density | Figure LASP-6: Floor Area Ratio [image omitted; see the official code] | [image omitted; see the official code] C. Height. 1. Building Height. Projects shall not exceed the height limits set in Figure LASP-7. a. Height is measured per Section 17.40.060. b. Maximum height for massing adjacent to street or interior property lines may be limited by required stepbacks; see Section 17.37.070.E. c. Exceptions allowed for projecting features such as appurtenances and railings per Section 17.40.060. D. Setbacks 1. Street Setbacks. Buildings shall comply with the street setbacks set in Figure LASP-8. Setback ranges establish a minimum and maximum for the specified percentage of linear street frontage; see Figure LASP-9. a. Street setbacks are measured from the sidewalk line; see Figure LASP-3. b. Minimum setbacks shall apply to all stories of a building; setbacks less than the minimum are prohibited. Maximum setbacks shall apply only to the ground floor. c. Residential units on the ground floor shall have a minimum setback of 5 feet. Where elevated between 4 and 6 feet above sidewalk elevation, a minimum setback of 8 feet shall be required. d. Exceptions allowed per Section 17.40.160 (Table 4-1) and the following: Arcades and recessed ground floors up to 15 feet in depth, as well as parking entrances per Section 17.37.100.B, are allowed when a second story meets the specified setback. e. For portions of buildings set back from the sidewalk line 5 feet or more, a percentage of the setback area shall be landscaped with trees, shrubs, and/or groundcover, either in the form of in-ground landscaping or planters. Figure LASP-7: Building Height | Figure LASP-8: Street Setbacks [image omitted; see the official code] | [image omitted; see the official code] Figure LASP-9: Street Setbacks Percentage | Figure LASP-10: Street Stepbacks [image omitted; see the official code] | [image omitted; see the official code] 2. Interior Setbacks. Buildings shall comply with the interior setbacks set in Table LASP-4 based on project type when adjacent to residential zoning districts. No setback is required when adjacent to other districts. a. Interior setbacks are those abutting other parcels (non-street side and rear) and are measured from the shared property line. b. Exceptions allowed per Section 17.40.160 (Table 4-1). Table LASP-4: Interior Setbacks Adjacent to RM/RS Project type | CG, CL, CF | MU-N | RM-16 Mixed-use | 15' min. | 15' min. | N/A Nonresidential | 15' min. | 15' min. | N/A Residential | N/A | 5' min. | 5' min. E. Stepbacks. 1. Street Stepbacks. Buildings utilizing a height concession per Section 17.43 shall provide a minimum stepback depth of 10 feet by a height of 36 feet along street frontages; see Figure LASP-10. a. Street stepbacks are those abutting public right-of-way and are measured from the sidewalk line. b. Uses allowed within the street stepback include: Private open space (e.g. terraces), shade structures (e.g. trellises), green roofs and photovoltaic panels, and other open space features per review authority approval. 2. Interior Stepbacks. Adjacent to RS zoning districts, buildings shall comply with the stepbacks below. Interior stepbacks are not required along other property lines. a. In all zones except LA-RM-16, projects shall not be located within the encroachment plane sloping upward and inward at a 45-degree angle measured from the vertical, commencing 15 feet above the existing grade along the shared property line; see Figure LASP-11. b. In LA-RM-16, projects shall step back a minimum of 15 feet at the second story and 50 feet at the third story, measured from the shared property line; see Figure LASP-11. c. Exceptions allowed per Section 17.40.160 (Table 4-2.1). Figure LASP-11: Setbacks and Stepbacks [image omitted; see the official code] F. Historic Adjacency. 1. Landmark Properties. Projects on parcels with a historic resource shall be subject to review for consistency with the Secretary of the Interior's Standards. 2. Transition Massing. Projects sharing a property line with a designated historic resource are subject to the following modified standards, illustrated in Figure LASP-12. a. Street Setbacks. The minimum street setback shall be an average of the minimum setback set in Figure LASP-9 and the established setback of the resource for a minimum of 20 feet from the shared property line. If located between two resources, the street setbacks shall be an average of the setbacks of the two resources for the full street frontage. b. Interior Setbacks. The minimum interior setback shall be equal to that of the historic resource or 15 feet, whichever is less. No setback is required where the resource is built to the shared property line. c. Street Stepbacks. A maximum streetwall height shall not exceed the height of the historic resource for a minimum of 20 feet from the shared property line. A stepback with a minimum depth of 10 feet is required above this height, measured from the modified minimum street setback. d. Interior Stepbacks. Projects shall not be located within an encroachment plane sloping upward and inward at a 30-degree angle measured from the vertical, commencing 15 feet above the existing grade at the property line; see Figure LASP-12. This plane is not applicable if the resource is built to the shared property line. Figure LASP-12: Historic Adjacency [image omitted; see the official code] G. Modulation. 1. Façade Length. In mixed-use districts, street-facing façades shall not exceed 150 feet in length unless there is a minimum break of 10 percent of the building length or 20 feet, whichever is greater. This break shall be a minimum of 10 feet deep, open to the sky; see Figure LASP-13. Projects in CF are exempt. Table LASP-5: Modulation Façade | CG | CL | CF | MU-N Length | 100' | 75' | 150' | 150' Area | 25% | 25% | 25% | 25% 2. Façade Area. Each street-facing façade exceeding 50 feet in length shall modulate a minimum of 25 percent of the area above the ground floor between 2 feet and 12 feet in depth from the primary façade plane; see Figure LASP-14. Buildings with a total of 2 stories or less are exempt. a. The primary façade plane is defined as the vertical plane with the greatest surface area above the ground floor. b. Modulation is not required to be continuous or open to the sky, and may be recessed or projected, but not beyond the sidewalk line. c. Modulation is not required to be continuous or open to the sky, and may be recessed or projected, but not beyond the sidewalk line. d. Required stepbacks (Section 17.37.070.E), façade breaks (Section 17.37.070.G.1), and projected balconies (Section 17.37.080.H.1) shall not count toward the modulation requirement; balconies that are recessed a minimum of 2 feet shall qualify. Figure LASP-13: Façade Length | Figure LASP-14: Façade Area [image omitted; see the official code] | [image omitted; see the official code] 3. Alternative Compliance. a. Eligibility. Modulation standards may be reduced or otherwise modified through the Design Review process if: (1) A minimum of 90% of the provided parking is fully or partially subterranean; (2) A minimum of one publicly accessible open space is provided at the ground level, visible and accessible from the sidewalk; (3) No other concessions, waivers, or incentives have been requested, including those associated with Section 17.43 (Density Bonus), unless the project is designed to achieve LEED Gold certification; and (4) The review authority makes all of the following findings. b. Required Findings. (1) The building design provides modulation on each street-facing façade in a manner consistent with the project's architectural style and/or immediate context, including adjacent historic resources. (2) The building design does not cause an adverse impact on the quality of the ground floor and public realm. (3) The ground level open space is of adequate size and integrated with the building in a functional way that ensures the space will be actively utilized. (4) The modification will not be detrimental to the health, safety, and welfare of the public. (5) The building design is consistent with the objectives and policies of the General Plan and LASP, as well as all other standards of the LASP.

(Ord. No. 7446, § 5, 5-12-2025; Ord. No. 7388, § 3(Exh. 2), 3-21-2022)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.