§ 17.37.080 — Frontage Standards
Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 17.37.080
Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/4ad12087-6cbc-4a4b-9e67-446058625856
17.37.080 - Frontage Standards
These standards are intended to: • Prioritize pedestrian access by ensuring doorways are open to a public sidewalk or public open space; • Increase visibility into ground floor uses to create visual interest for pedestrians; • Promote shade through arcades and shade structures; • Support a consistent character when different uses are allowed on the ground floor within the same block; • Promote consistent ground floor heights when residential and commercial uses are present within the same zone; and • Limit blank walls on the ground floor to enhance visual interest and pedestrian comfort. A. Ground Floor. 1. Height. Buildings facing Lincoln Avenue shall have a minimum ground floor height of 15 feet, measured from the sidewalk elevation to second-story floor or roof of a one-story building; see Figure LASP-15. a. Exception: Ground floor residential uses with a setback of 10 feet or greater shall have a minimum ground floor height of 12 feet. b. For residential units, the first habitable floor shall be located between 6 feet above and 2 feet below sidewalk elevation. 2. Depth. Commercial uses shall have an average interior depth of at least 35 feet and a minimum depth of 20 feet, measured wall-to-wall. Figure LASP-15: Ground Floor Height [image omitted; see the official code] B. Entrances. 1. Location. A minimum of one primary entrance shall be located on the primary frontage of each building and open onto a sidewalk or public space. a. In LA-CG, entrances shall be recessed a minimum of 30 inches from the ground floor building façade along Lincoln Avenue. On other streets, entrances shall be recessed a minimum of 30 inches from the sidewalk line. b. Primary entrances shall be distinguished by architectural features or overhead projections, such as an awning or canopy. c. For non-residential uses, primary entrances shall be located at sidewalk elevation. d. Exception allowed for residential courtyard buildings with unit entrances off the courtyard. Courtyards shall be entered from the street through an architecturally defined entry (covered or open to the sky) or portico. C. Transparency. 1. Windows & Doors. Minimum transparency for street-facing façades is set in Tables LASP-6 and LASP-7 based on use. a. For non-residential and residential common space uses, ground floor transparency is measured as the percentage of building frontage that consists of transparent openings between a height of 2 feet and 10 feet above sidewalk elevation. b. All other transparency is measured as the percentage of building frontage area, viewed in elevation and excluding any coverage of shading devices. c. Windows shall be recessed by a minimum of 3 inches from the façade, measured from the outside wall to the frame of the window (mullion, muntin or similar element).Flush windows shall be permitted where exterior shading devices cover a minimum of 25 percent of the window surface area or per review authority approval. d. The use of tinted, mirrored or highly reflective glazing is prohibited. e. Street-facing transparency blocked by walls and fences over 42 inches shall not count towards required transparency f. Blinds, drapes, posters, and shelving for product displays visible to the public right-of-way may obscure a maximum of 10 percent of the transparent areas of each respective storefront or 50 percent for medical office uses. Table LASP-6: Transparency for Non-Residential and Residential Common Space Transparency | CG | CL | CF | MU-N Ground Floor | 70% | 30% | 30% | 70% Overall Façade | 30% | 15% | 15% | 30% Table LASP-7: Transparency for Residential Units Transparency | CG | CL | CF | MU-N Ground Floor | N/A | 15% Overall Façade | N/A | 15% 2. Blank Walls. Windowless expanses of street-facing walls shall not exceed 20 feet in length. 3. Security Bars. Any exterior or interior security bars shall be designed to be fully hidden from view during business hours with devices such as concealed side pockets and ceiling cavities. D. Shade Structures. 1. Shading. Shade structures may project up to two-thirds of the sidewalk width. In LA-CG along Lincoln Avenue, shade structures (e.g. awnings and canopies) are required, subject to a Public Works permit, and shall project a minimum of 5 feet and up to a maximum of 10 feet into the public right-of-way for a minimum of 50 percent of the building frontage. a. Shade structures shall allow a minimum of 8 feet of vertical clearance from sidewalk elevation and shall not conflict with existing trees. b. Shade structures are not required where an arcade or recessed ground floor provides a minimum of 5 feet of unobstructed pedestrian clearance. E. Arcades & Galleries. 1. Arcades. Any arcades shall be located behind the minimum setback. a. Arcades shall be a minimum of 8 feet from back of column to building façade. b. The distance between columns shall be at least the same dimension as arcade depth, as measured from the column center. c. The façade shall meet the ground floor transparency set in Section 17.37.080.C. d. Uses allowed within arcades include: pedestrian travel, seating/street furniture, outdoor dining, landscape planters, and/or bicycle parking. 2. Galleries. Any galleries shall be located behind the minimum setback. a. Galleries shall be limited to one-story and 50 percent of the building frontage b. Galleries shall allow a minimum of 10 feet of vertical clearance from sidewalk elevation. F. Exterior Fixtures 1. Façade Lighting. In LA-CG, pedestrian-scale lighting, such as sconces and goose-neck fixtures, shall be located on the building frontage a minimum of every 30 feet along Lincoln Avenue. a. Façade lighting shall be full cutoff (directing light downward and outward). b. Fixtures shall be located between 8 and 15 feet above sidewalk elevation, and shall not project more than 30 inches from the façade. c. Lighting shall be static; flashing, pulsating or other dynamic lighting is not permitted. G. Walls & Fences. 1. LA-CG, -CL, -MU-N and -RM-16 Zones. Walls, fences, raised planters, screening and similar structures (walls/fences) shall be permitted within the required street setback subject to the following conditions. All other walls and fences shall be subject to Section 17.40.180. a. Maximum height shall not exceed 42 inches. b. Walls/fences taller than 30 inches shall be a minimum of 50 percent transparent. c. A minimum 24 inch setback from the sidewalk line is required, separated by planted area; retaining walls with a maximum height of 30 inches are exempt from this requirement. d. Stoops and Patios. The side of a patio or stoop (when parallel to a sidewalk) taller than 30 inches in height shall be set back a minimum of 18 inches from the sidewalk line, separated by planted area. 2. LA-CF Zone. Walls/fences located in front of a structure shall be subject to Section 17.37.080.G.1. Walls/fences not located in front of a structure, but along a street frontage, shall be permitted subject to the following conditions: a. A minimum of 5 foot setback from the sidewalk line shall be required, separated by planted area. b. Maximum height shall not exceed 96 inches. (1) Portions of walls/fences greater than 60 inches in height shall be a minimum of 50 percent transparent; portions 60 inches in height or lower are permitted to be solid walls. (2) Solid walls/fences integrated with the building architecture may be permitted to match the height of the ground floor, with a maximum length of 20 feet. Landscaping shall be provided between the solid wall/fence and the sidewalk line, with the exception for building/property entrances. 3. Exceptions. a. Exceptions to wall/fence height allowed for guardrails, which may exceed the maximum height to the extent required by the Building Code. The guardrail shall be a minimum of 50 percent transparent. b. Exceptions to required wall/fence setback allowed for outdoor dining, which may be enclosed by a wall, fence, or similar structure up to a maximum of 42 inches in height located at the sidewalk line. H. Balconies & Roof Decks. 1. Balconies. Balconies may project a maximum of 4 feet into a street setback but shall not extend beyond the sidewalk line or within 6 feet of any interior property line. Balconies shall not project from a building façade within 50 feet of an RS zoning district. 2. Roof Decks. Roof decks shall be not be located within 50 feet of an RS zoning district. The sum of all roof decks shall not exceed a maximum coverage of 50 percent of the roof area.
(Ord. No. 7446, § 5, 5-12-2025; Ord. No. 7388, § 3(Exh. 2), 3-21-2022)
Ask a question about Pasadena law
Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.
