§ 15.42.080: Analysis and design.

A. General. Every structure within the scope of this chapter shall be analyzed and constructed to resist minimum total lateral seismic forced assumed to act nonconcurrently in the direction of each of the main axes of the structure in accordance with the following equation: V = ZIKCSW (Formula III-1) The value of KCS need not exceed the values set forth in Table Number Ill-A (Exhibit A attached to the ordinance codified in this chapter and located at the end of this chapter) based on the seismic zone as determined by the building code. The value of Z shall be the value specified in Table Number Ill-B (Exhibit A). The I factor shall be as specified in Table Number Ill-C (Exhibit A). The value of W shall be as set forth in the Uniform Building Code, 1988 Edition. B. Lateral forces on elements of structures. Parts or portions of structures shall be analyzed and designed for lateral loads in accordance with subsection A of this section and Chapter 23, Uniform Building Code, 1988 Edition, but not less than the value from the following equation: Fp = ZICp SWp (Formula III-2) For the provisions of this subsection, the product of IS need not exceed the values as set forth in Table Number III-D (Exhibit A). The value of Cp need not exceed the values as set forth in Table Number III-M (Exhibit G). The value of Wp shall be as set forth in the Uniform Building Code, 1988 Edition. Exception. Unreinforced masonry walls may be analyzed in accordance with section 15.42.090. C. Anchorage and interconnection. Anchorage and interconnection of all parts, portions and elements of the structure shall be analyzed and designed for lateral forces in accordance with the Uniform Building Code, 1988 Edition and the equation: Fp = ZICp 2) as modified by Table Number III-D (Exhibit A). Minimum anchorage of masonry walls to each floor or roof shall resist a minimum force of 200 pounds per linear foot acting normal to the wall at the level of the floor or roof. D. Level of required repair. Alterations and repairs required to meet the provisions of this chapter shall comply with all other applicable requirements of the Uniform Building Code, 1988 Edition, unless specifically provided for in this chapter. E. Required analysis. Except as modified in this subsection, the analysis and design relating to the structural alteration of existing structures within the scope of this chapter shall be in accordance with the analysis specified in Chapter 23, Uniform Building Code, 1988 Edition. 1. Continuous stress path. A complete, continuous stress path from every part or portion of the structure to the ground shall be provided for the required horizontal forces. 2. Positive connections. All parts, portions or elements of the structure shall be interconnected by positive means. F. Analysis procedure. Stresses in materials and existing construction utilized to transfer seismic forces from the ground to parts or portions of the structure shall conform to those permitted by the Uniform Building Code, 1988 Edition, and those materials and types of construction specified in section 15.42.090. Materials and connectors used for interconnection of parts and portions of the structure shall conform to the Uniform Building Code, 1988 Edition. Except as modified in this chapter, unreinforced masonry walls shall be analyzed as specified in Sections 2416, 2418 and 2419 of the Uniform Building Code, 1988 Edition, to withstand all vertical loads as specified in Chapter 23, Uniform Building Code, 1988 Edition, in addition to the seismic forces required by this chapter. No allowable tension stress will be permitted in unreinforced masonry walls. Walls not capable of resisting the required design forces specified in this chapter shall be strengthened or shall be removed or replaced. Exceptions. 1. Unreinforced masonry walls may be analyzed in accordance with section 15.42.090. 2. Unreinforced masonry walls which carry no design loads other than its own weight may be considered as veneer if they are adequately anchored to new supporting elements. 3. The 50 percent increase in the seismic force factor for shear walls as specified in Table Number 24-H of the Uniform Building Code, 1988 Edition, may be omitted in the computation of seismic loads to existing shear walls. G. Combination of vertical and seismic forces. All new materials introduced into the structure to meet the requirements of this section which are subjected to combined vertical and horizontal forces, shall comply with Section 104(b) of the Uniform Building Code, 1988 Edition, except as follows: 1. Stresses in existing lateral force resisting elements due to a combination of dead loads, plus live loads, plus seismic loads may be increased 100 percent over allowable working stresses specified in the Uniform Building Code, 1988 Edition, however, shall not exceed those permitted by section 15.42.090; 2. Stresses in members due only to seismic and dead loads shall not exceed the values permitted by Section 2303(d) of the Uniform Building Code, 1988 Edition; 3. Calculated tensile fiber stress may be reduced by the full direct stress due to vertical dead loads.

( Code 1980, § 15.42.080 ; Ord. No. 417 § 4, 1990 ; Ord. No. 870 (Recodification), 2014 )

Ask a question about Rancho Cucamonga law

Corpus searches the Rancho Cucamonga sections it holds and shows the ones that match, with their citations. Free, no sign-in.