§ 15.42.110 — Tables

Municipal Code, City of Rancho Cucamonga, California (Code 2026-09-02) · Rancho Cucamonga Municipal Code § 15.42.110

Corpus is an independent public-information project, not the official City of Rancho Cucamonga website. Stable reference: corpuslaw.us/code/684a77f6-9d9f-43f9-aee3-df7968083b69

§ 15.42.110: Tables.

Table III-AHORIZONTAL FORCE FACTORS BASED ON OCCUPANT LOAD Occupant Load | KCS Building with an occupant load greater than 100 | 0.133 All others | 0.100 Table III-BZ FACTOR Seismic Zone | Factor Zone 4 | 1 Table III-CI FACTOR Occupancy | Factor All buildings (high, medium and low risk) | 1.0 Table III-DHORIZONTAL FORCE FACTORS "IS" FOR PARTS OR PORTIONS OF STRUCTURES Rating Classification | IS High risk building medium and low risk buildings | 1.00 .75 Table III-EREGULATED ELEMENTS Building Element | Seismic Zone 4 Walls: h/t Ratio Tension bolts (bending) In-plane shear Parapets Floors and Roofs: Diaphragm stress and diaphragm chords | x x x x x Table III-FALLOWABLE VALUE OF HEIGHT-THICKNESS RATIO OF UNREINFORCED MASONRY WALLS WITH MINIMUM QUALITY MORTAR Buildings with Crosswalks as defined by section 15.42.030 | All Other Buildings Walls of one story buildings | 16 | 13 First story wall of multi-story building | 16 | 15 Walls in top story of multi-story buildings | 14 | 9 All other walls | 16 | 13 1 | Minimum quality mortar shall be determined by laboratory testing in accordance with section 15.42.090.(A)(1)(e). 2 | Table III-G is not applicable to buildings of rating classification I. Walls of buildings within rating classification I shall be analyzed in accordance with section 15.42.080(F). Table III-GVALUES FOR EXISTING MATERIALS New Materials or Configuration of Materials 1 | Allowable Values 1. Horizontal diaphragms a. Roofs with straight sheathing and roofing applied directly to the sheathing. | 100 lbs./ft. for seismic shear. b. Roofs with diagonal sheathing and roofing applied directly to the sheathing. | 400 lbs./ft. for seismic shear. c. Floors with straight tongue and groove sheathing. | 150 lbs./ft. for seismic shear. d. Floors with straight sheathing and finished wood flooring. | 300 lbs./ft. for seismic shear. e. Floors with diagonal sheathing and finished wood flooring. | 450 lbs./ft. for seismic shear. f. Floors or roofs with straight sheathing and plaster applied to the joist or rafters. 2 | Add 50 lbs./ft. to the allowable values for items 1.a. & c. 2. Shear walls a. Wood stud walls with lath and plaster. | 100 lbs./ft. each side for seismic shear. 3. Plain concrete footings | f = 1500 psi unless otherwise shown by tests. 4. Douglas Fir Wood | Allowable stress same as #1 D.F. 3 5. Reinforcing Steel | ft = 18,000 lbs./sq. ft. maximum 3 6. Structural Steel | ft = 20,000 lbs./sq. ft. maximum 3 1 | Material must be sound and in good condition. 2 | The wood lath and plaster must be reattached to existing joists or rafters in a manner approved by the building official. 3 | Stresses given may be increased for combinations of loads as specified in section 15.42.080(G)(2). Table III-HALLOWABLE VALUES OF NEW MATERIALS USED IN CONJUNCTION WITH EXISTING CONSTRUCTION New Materials or Configuration of Materials | Allowable Values 1. | Horizontal Diaphragms Plywood sheathing applied directly over existing straight sheathing with ends of plywood sheets bearing on joists or rafters and edges of plywood located on center of individual sheathing boards. | Same as specified in Table 25-J of UBC, '88 Ed., for blocked diaphragms. 2. | Shear Walls a. Plywood sheathing applied directly over existing wood studs. No value shall be given to plywood applied over existing plaster or wood sheathing. | Same as values specified in UBC, '88 Ed., Table 25-K for shear walls. b. Dry wall or plaster applied directly over existing wood studs. | 75% of the values specified in UBC, '88 Ed., Table #47-I. c. Dry wall or plaster applied to plywood sheathing over existing wood studs. | 33 1/3 % of the value specified in UBC, '88 Ed., Table #47-I. 3. | Shear Bolts Shear bolts and dowels embedded a mm. of 8″ into unreinforced masonry walls. Bolt centered in a 2½″ diameter hole with dry-pack or non-shrink grout around circumference of bolt or dowel. 1, 3 | 100% of the value for plain masonry specified in UBC, '88 Ed., Table #24-G. No values larger than those given for ¾″ bolts shall be used. 4. | Tension Bolts Tension bolts and dowels extending entirely through unreinforced masonry walls secured w/bearing plates on far side of wall with at least 30 sq. ft. of area of area. 2, 3 | 1,200 lbs. per bolt or dowel. 5. | Wall Anchors (section 15.42.100B.1). Bolts extending to the exterior face of the wall with a 2½′ round plate under the head. Install as specified for shear bolts. Spaced not closer than 12′ on centers. 1, 2, 3 | 600 lbs. per bolt. 6. | Bolts or dowels extending to the exterior face of the wall with a 2½' round plate under the head and drill at an angle of 22½ degrees to the horizontal. Installed as specified for bolts. 1, 2, 3 | 1,200 lbs. per bolt or dowel. 7. | Infilled Walls Reinforced masonry infilled openings in existing unreinforced masonry walls with keys or dowels to match reinforcing. | Same as value specified for unreinforced masonry walls. 8. | Reinforced Masonry Masonry piers and walls reinforced per Sec. 2417, UBC, 88 Ed. | Same as values specified in Table #24-B, UBC, 1988 Ed. 9. | Reinforced Concrete Concrete footings, walls and piers reinforced as specified In Chapter 26, UBC, 1988 Ed., and designed for tributary loads. | Same as values specified Chapter 26, UBC, 1988 Ed. 10. | Existing Foundation Loads Foundation loads for structures exhibiting no evidence of settlement. | Calculated existing foundation loads due to maximum dead load + live load may be increased 25% for dead load, and may be increased 50% for dead load + seismic load required by this chapter. 1 | Bolts and dowels to be tested as specified in section 15.42.090(f). 2 | Bolts and dowels to be one-half inch minimum in diameter. 3 | Drilling for bolts and dowels shall be done with an electric rotary drill. Impact tools shall not be used for drilling holes or tightening anchor and shear bolt nuts. Table III-IALLOWABLE SHEAR STRESS FOR TESTED UNREINFORCED MASONRY WALLS 80% of Test Results in PSI Not Less Than | Average Test Results of Cores in PSI | Seismic In-Plane Shear Based on Gross Area 30 plus axial stress | 20 | 3 psi* 40 plus axial stress | 27 | 4 psi* 50 plus axial stress | 33 | 5 psi* 100 plus axial stress or more | 67 or more | 10 psi max* * | Allowable shear stress may be increased by addition of ten percent of the axial stress due to the weight of the wall directly above. Table III-KSERVICE PRIORITIES AND EXTENDED TIME PROVISIONS Rating Classification | Occupant Load | Minimum Time Periods for Service of Order | Extension of Time After Wall Anchors are Installed High risk building | 100 or more | 270 days | 180 days Medium risk building | More than 20 but less than 100 | 270 days | 180 days Low risk building | Less than 20 | 270 days | 1 year * | Measured from the effective date of this article. Table III-LHORIZONTAL FORCE FACTORS BASED ON RATING CLASSIFICATION Rating Classification | IKCS High risk building | 0.133 Medium/low risk building | 0.100 Table III-MHORIZONTAL FORCE FACTOR "CP" FOR PARTS OR PORTIONS OF BUILDINGS OR OTHER STRUCTURES 1 Part of Portion of Building | Direction of Force | Value of CP Exterior bearing and non-bearing walls, interior bearing walls and partitions, interior non-bearing walls and partitions over 10 inches in height, masonry fences over 6 inches in height. | Normal to flat surface | 0.20 Cantilever parapet and other cantilever walls, except retaining walls. | Normal to flat surface | 1.00 Exterior and interior ornamentations and appendages. | Any direction | 1.00 When connected to or part of a building; towers, tanks, towers and tanks + contents racks over 8" 3' in height + contents, chimneys, smokestacks, and penthouses. | Any direction | 0.24 2,4 When connected to or part of a building: Rigid and rigidly mounted equipment and machinery not required for continued operation of essential occupancies. | Any horizontal direction | 0.20 3 Tanks + effective contents resting on ground. | Any direction | 0.12 Floors and roofs acting as diaphragms. | In the plane of the diaphragm | 0.12 6 Prefabricated structural elements, other than walls, with force applied at center of gravity of assembly. | Any horizontal direction | 0.30 Connections for exterior panels or elements. | Any direction | 2.0 1 | See section 15.42.080(B) for use of CP 2 | When located in the upper portion of any building with a ratio of 5 to 1 or greater the value shall be increased by 50 percent. 3 | For flexible and flexibly mounted equipment and machinery, the appropriate values for CP shall be determined with consideration given to both the dynamic properties of the equipment and machinery, and to the building or structure in which it is placed. 4 | The W for storage racks shall be the weight of the racks plus contents. The value of CP for racks over two storage support levels in height shall be 0.16 for the levels below the top two levels. 5 | The design of the equipment and machinery and their anchorage is an integral part of the design and specification of such equipment and machinery. The structure to which the equipment or machinery is mounted shall be capable of resisting the anchorage forces (see also Section 2313(k), UBC, 1988 Edition). 6 | Floor and roofs acting as diaphragms shall be designed for a minimum force resulting for a CP of 0.12 applied to W unless a greater force results from the distribution of lateral forces in accordance with Section 2312(e), USC, 1988 Edition.

( Code 1980, ch. 15.42, tables III-A—III-I, III-K—III-M ; Ord. No. 417 § 4, 1990 ; Ord. No. 417-A , 1991 ; Ord. No. 870 (Recodification), 2014 )

Ask a question about Rancho Cucamonga law

Corpus searches the Rancho Cucamonga sections it holds and shows the ones that match, with their citations. Free, no sign-in.