11.04.180 - Excavation—Depth and location of pipes and conduits.*

Whenever any pipe for conducting water or gas, or conduits for conducting electric, community antenna television or telephone along any street are laid by any person, such pipe or conduit are laid as follows, unless special permission to the contrary has been given by the city engineer: A. Water and gas requirements are as follows: 1. All domestic water pipe mains shall be laid at such depth that the top of such pipes is not less than thirty inches below the established grade of the street, and all gas pipe mains shall be laid at such depth that the top of such pipes is not less than thirty inches below the established grade of the street; provided, however, that in cases where the grades may not have been established, these depths shall be below the existing surface of the street. 2. Water pipes shall, where practicable, be laid a minimum of twelve feet from the centerline of the street on the southerly or westerly side thereof. 3. Gas pipes shall, where practicable, be laid six feet toward the center of the street from the curb line of the street on the northerly or easterly side thereof. B. Sewer requirements are as follows: 1. All sewer mains shall be laid at such depth that the top of such mains are not less than six feet below the established grade of the street; provided, however, that in cases where the grades may not have been established, these depths shall be below the existing surface of the street. 2. Sewer mains shall, where practicable, be laid a minimum of five feet from the centerline of the street on the northerly or easterly side thereof. 3. Water and sewer lines should be separated as far as is reasonably possible and the water mains should be kept as far as possible above the elevation of any nearby sewer. Under normal conditions the minimum horizontal separation should be ten feet with the sewer line at least three feet below the water line. Installation in the same trench is prohibited. If because of the topography or physical conditions there is no alternative but to install water and sewer lines near each other, then special construction is necessary to the satisfaction of the city engineer. At no time shall there be less than six inches separation between water and sewer lines. 4. Sewer mains crossing above water mains shall be made self-supporting over the water main for a length equal to the width of the water main trench plus two feet measured perpendicular to each edge of the water main trench. C. Electric, Telephone, and Community Antenna Television requirements are as follows: 1. All underground electrical, community antenna television and telephone facilities shall be installed in accordance with G.O. 128 of the state of California, Public Utilities Commission. 2. The underground electrical mains for residential service and community antenna television and telephone conduits shall, where practicable, be laid a maximum of one foot from the edge of sidewalk towards the curb and major electrical mains in the street shall be laid at a location to be determined by the city engineer. *Subdivision (B)(3) was editorially amended at the request of the city attorney.

(Ord. 604 § 1 (part), 1971: 1965 code Title XIII, Ch. 3, § 4(B))

Ask a question about Rialto law

Corpus searches the Rialto sections it holds and shows the ones that match, with their citations. Free, no sign-in.