For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12.27.011 — General sewer use requirements

Municipal Code of the City of Rialto, California (Codified through Ordinance No. 1713, passed April 28, 2026. (Supp. No. 39)) · Rialto Municipal Code § 12.27.011

Corpus is an independent public-information project, not the official City of Rialto website. Stable reference: corpuslaw.us/code/63900fb1-53a6-4e70-9413-8f03b0d088da

12.27.011 - General sewer use requirements.

A. Prohibited Discharge Standards. 1. General Prohibitions. No user shall introduce or cause to be introduced into the POTW any pollutant or wastewater which causes pass through or interference. These general prohibitions apply to all users of the POTW whether or not they are subject to categorical pretreatment standards or any other national, state, or local pretreatment standards or requirements. 2. Specific Prohibitions. No user shall introduce or cause to be introduced into the POTW the following pollutants, substances, or wastewater: a. Pollutants which create a fire or explosive hazard in the POTW, including, but not limited to, wastestreams with a closed cup flashpoint of less than one hundred forty degrees Fahrenheit (sixty degrees Celsius) using the test methods specified in 40 CFR 261.21; b. Wastewater having a pH less than 5.0 or more than 11.5, or otherwise causing corrosive structural damage to the POTW or equipment; c. Solid or viscous substances in amounts which will cause obstruction of the flow in the POTW resulting in interference but in no case solids greater than one half inch in any dimension; d. Pollutants, including oxygen demanding pollutants (BOD, etc.), released in a discharge at a flow rate and/or pollutant concentration which, either singly or by interaction with other pollutants, will cause interference with the POTW; e. Wastewater having a temperature which will inhibit biological activity in the treatment plant resulting in interference, but in no case wastewater which causes the temperature at the introduction into the treatment plant to exceed one hundred four degrees Fahrenheit (forty degrees Celsius); f. Petroleum oil, non-biodegradable cutting oil, or products of mineral oil origin, in amounts that will cause interference or pass through; g. Pollutants which result in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may cause acute worker health and safety problems; h. Trucked or hauled pollutants, except at discharge points designated by the city; i. Noxious or malodorous liquids, gases, solids, or other wastewater which, either singly or by interaction with other wastes, are sufficient to create a public nuisance or a hazard to life, or to prevent entry into the sewers for maintenance or repair; j. Wastewater which imparts color which cannot be removed by the treatment process, such as, but not limited to, dye wastes and vegetable tanning solutions, which consequently imparts color to the treatment plant's effluent, thereby violating the city's WDR (wastewater discharge requirements and NPDES permit); k. Wastewater containing any radioactive wastes or isotopes except in compliance with applicable state or federal regulations; l. Stormwater, surface water, groundwater, artesian well water, roof runoff, subsurface drainage, swimming pool drainage, condensate, deionized water, non-contact cooling water, and unpolluted wastewater, unless specifically authorized by the city; m. Sludges, screenings, or other residues from the pretreatment of industrial wastes; n. Medical wastes, except as specifically authorized by the city in a wastewater discharge permit; o. Wastewater causing, alone or in conjunction with other sources, the treatment plant's effluent to fail toxicity testing; p. Detergents, surface active agents, or other substances which that might cause excessive foaming in the POTW; q. Wastewater causing two readings on an explosion hazard meter at the point of discharge into the POTW, or at any point in the POTW, of more than five percent or any single reading over ten percent of the lower explosive limit of the meter. 3. Process and Storage. Pollutants, substances, or wastewater prohibited by this section shall not be processed or stored in such a manner that they could be discharged to the POTW. B. National Categorical Pretreatment Standards. Users must comply with the categorical pretreatment standards found at 40 CFR Chapter I, Subchapter N, Parts 405-471. 1. Where a categorical pretreatment standard is expressed only in terms of either the mass or the concentration of a pollutant in wastewater, the city may impose equivalent concentration or mass limits in accordance with Sections 12.27.011(B)(2) and 12.27.011(B)(5). 2. When the limits in a categorical pretreatment standard are expressed only in terms of mass of pollutant per unit of production, the city may convert the limits to equivalent limitations expressed either as mass of pollutant discharged per day or effluent concentration for purposes of calculating effluent limitations applicable to individual industrial users. 3. When wastewater subject to a categorical pretreatment standard is mixed with wastewater not regulated by the same standard, the city shall impose an alternate limit in accordance with 40 CFR 403.6(e). 4. A CIU may obtain a net/gross adjustment to a categorical pretreatment standard in accordance with the following paragraphs of this section. a. Categorical pretreatment standards may be adjusted to reflect the presence of pollutants in the industrial user's intake water in accordance with this section. Any industrial user wishing to obtain credit for intake pollutants must make application to the city. Upon request of the industrial user, the applicable standard will be calculated on a "net" basis (i.e., adjusted to reflect credit for pollutants in the intake water) if the requirements of subsection (B)(4)(b) of this section are met. b. Criteria. i. Either: (A) The applicable categorical pretreatment standards contained in 40 CFR subchapter N specifically provide that they shall be applied on a net basis; or (B) The industrial user demonstrates that the control system it proposes or uses to meet applicable categorical pretreatment standards would, if properly installed and operated, meet the standards in the absence of pollutants in the intake waters. ii. Credit for generic pollutants such as biochemical oxygen demand (BOD), total suspended solids (TSS), and oil and grease should not be granted unless the industrial user demonstrates that the constituents of the generic measure in the user's effluent are substantially similar to the constituents of the generic measure in the intake water or unless appropriate additional limits are placed on process water pollutants either at the outfall or elsewhere. iii. Credit shall be granted only to the extent necessary to meet the applicable categorical pretreatment standard(s), up to a maximum value equal to the influent value. Additional monitoring may be necessary to determine eligibility for credits and compliance with standard(s) adjusted under this section. iv. Credit shall be granted only if the user demonstrates that the intake water is drawn from the same body of water as that into which the POTW discharges. The city may waive this requirement if it finds that no environmental degradation will result. 5. When a categorical pretreatment standard is expressed only in terms of pollutant concentrations, an industrial user may request that the city convert the limits to equivalent mass limits. The determination to convert concentration limits to mass limits is within the discretion of the city. The city may establish equivalent mass limits only if the industrial user meets all the conditions set forth in subsections (B)(5)(a) through (B)(5)(e) below. a. To be eligible for equivalent mass limits, the industrial user must: i. Employ, or demonstrate that it will employ water conservation methods and technologies that substantially reduce water use during the term of its wastewater discharge permit; ii Currently use control and treatment technologies adequate to achieve compliance with the applicable categorical pretreatment standard, and not have used dilution as a substitute for treatment; iii. Provide sufficient information to establish the facility's actual average daily flow rate for all wastestreams, based on data from a continuous effluent flow monitoring device, as well as the facility's long-term average production rate. Both the actual average daily flow rate and the long-term average production rate must be representative of current operating conditions; iv. Not have daily flow rates, production levels, or pollutant levels that vary so significantly that equivalent mass limits are not appropriate to control the discharge; and v. Have consistently complied with all applicable categorical pretreatment standards during the period prior to the industrial user's request for equivalent mass limits. b. An industrial user subject to equivalent mass limits must: i. Maintain and effectively operate control and treatment technologies adequate to achieve compliance with the equivalent mass limits; ii. Continue to record the facility's flow rates through the use of a continuous effluent flow monitoring device; iii. Continue to record the facility's production rates and notify the city whenever production rates are expected to vary by more than twenty percent from its baseline production rates. Upon notification of a revised production rate, the city will reassess the equivalent mass limit and revise the limit as necessary to reflect changed conditions at the facility; and iv. Continue to employ the same or comparable water conservation methods and technologies so long as it discharges under an equivalent mass limit. c. When developing equivalent mass limits, the city: i. Will calculate the equivalent mass limit by multiplying the actual average daily flow rate of the regulated process(es) of the industrial user by the concentration-based daily maximum and monthly average standard for the applicable categorical pretreatment standard and the appropriate unit conversion factor; ii. Upon notification of a revised production rate, will reassess the equivalent mass limit and recalculate the limit as necessary to reflect changed conditions at the facility; and iii. May retain the same equivalent mass limit in subsequent wastewater discharger permit terms if the industrial user's actual average daily flow rate was reduced solely as a result of the implementation of water conservation methods and technologies, and the actual average daily flow rates used in the original calculation of the equivalent mass limit were not based on the use of dilution as a substitute for treatment pursuant to Section 12.27.011(F) of this chapter. The industrial user must also be in compliance with Section 12.27.022(C) regarding the prohibition of bypass. C. State Pretreatment Standard. Users must comply with state pretreatment standards. D. Local Limits. 1. Numerical Discharge Limitations. a. Heavy Metals and Cyanide. The following pollutant limits are established to protect against pass through and interference. These numerical discharge limitations apply at the point where the wastewater is discharged to the POTW. This discharge point is considered the "end-of-pipe". The city may impose mass limitations in addition to, or in place of, the concentration-based limits. Where a user is subject to a categorical pretreatment standard and a local limit for a given pollutant, the more stringent limit or applicable pretreatment standard shall apply. No user shall discharge wastewater containing pollutant levels in excess of the following maximum daily limits: Pollutant | Symbol | Maximum Daily Concentration Limit Heavy Metals Arsenic, Total | As | 1.5 Cadmium, Total | Cd | 0.4 Chromium, Total | Cr | 3.0 Copper, Total | Cu | 3.5 Lead, Total | Pb | 0.7 Mercury, Total | Hg | 0.05 Molybdenum, Total | Mo | 3.3 Nickel, Total | Ni | 4.0 Selenium, Total | Se | 1.5 Silver, Total | Ag | 0.4 Zinc, Total | Zn | 2.6 Cyanide, Total | CN | 3.4 b. Five-day Biochemical Oxygen Demand (BOD). No user shall discharge wastewater containing concentrations of five-day biochemical oxygen demand (BOD) greater than four hundred mg/L without first obtaining written authorization to discharge from the city. The city may issue significant industrial users (SIU) a mass based limit to prevent pass through or interference of the POTW. All mass based limits will be issued under a wastewater discharge permit as authorized under this chapter. c. Total Suspended Solids (TSS). No user shall discharge wastewater containing concentrations of total suspended solids (TSS) greater than four hundred mg/L without first obtaining written authorization to discharge from the city. The city may issue significant industrial users (SIU) a mass based limit to prevent pass through or interference of the POTW. All mass based limits will be issued under a wastewater discharge permit as authorized under this chapter. d. Ammonia (NH3). No user shall discharge wastewater containing concentrations of ammonia (NH3) greater than fifty mg/L without first obtaining written authorization to discharge from the city. The city may issue significant industrial users (SIU) a mass based limit to prevent pass through or interference of the POTW. All mass based limits will be issued under a wastewater discharge permit as authorized under this chapter. e. Total Inorganic Nitrogen (TIN). No user shall discharge wastewater containing of total inorganic nitrogen (TIN) in quantities that alone or in conjunction with other pollutant cause pass through or interference. No user shall discharge wastewater with TIN quantities greater than eighty mg/L without meeting one of the following: i. Development and implementation of a best management program to minimize the TIN pollutants in the user's discharge; or ii. Obtain a site specific discharge limit (concentration based or mass based) to prevent pass through or interference of the POTW. TIN limits under this provision, shall be issued under a wastewater discharge permit as authorized under this chapter. The city may, in addition to, or in-place of, TIN limits, establish concentration based or mass based limits on specific constituents of the total inorganic nitrogen. f. Fat, Oil and Grease (FOG). No user shall discharge wastewater containing concentrations of fats, oils and greases (FOG) greater than one hundred mg/L without meeting one of the following: i. Compliance to the city's FOG grease trap/interceptor best management program; or ii. Obtain a site specific discharge limit (concentration based or mass based) to prevent pass through or interference of the POTW. FOG limits under this provision, shall be issued under a wastewater discharge permit as authorized under this chapter. Fat, oil and grease (FOG) is defined as the n-hexane extractable material (HEM) measured in the EPA Method 1664. FOG represents all sources of fats, oils and greases, including those of animal, vegetable, mineral spirit, and petroleum origin. g. Oil and Grease (O&G). No user shall discharge wastewater containing concentrations of oil and grease greater than fifty mg/L without meeting one of the following (please note the difference between FOG and O&G as defined in Sections 12.27.011(D)(1)(f) and 12.27.011(D)(1)(g) of this chapter): i. Development and implementation of a best management program to prevent the introduction of petroleum based oils and greases in amounts that will cause pass through or interference of the POTW; or ii. Obtain a site specific discharge limit (concentration based or mass based) to prevent pass through or interference of the POTW. O&G limits under this provision, shall be issued under a wastewater discharge permit as authorized under this chapter. Oil and grease (O&G) is defined as the material measured in EPA Method 1664 following silica gel treatment, n-hexane extractable material. O&G represents only those fats, oils and greases of mineral spirit origin. It does not include fats, oils, and greases of animal or vegetable origin, or the light oils of petroleum origin. h. Total Dissolved Solids (TDS). No user shall discharge wastewater containing concentrations of total dissolved solids (TDS) greater than eight hundred mg/L without meeting one of the following: i. Development and implementation of a best management program to minimize the TDS pollutants in the user's discharge; or ii. Obtain a site specific discharge limit (concentration based or mass based) to prevent pass through or interference of the POTW. TDS limits under this provision shall be issued under a wastewater discharge permit as authorized under this chapter. The city may, in addition to, or in-place of, TDS limits, establish concentration based or mass based limits on specific constituents of the total dissolved solids. 2. Best Management Practices. The city may require users to develop and implement best management practices (BMPs) to comply with the provisions of Sections 12.27.011(A) and 12.27.011(D) of this chapter. Best management practices implemented under this subsection shall become the local limit and enforced as a pretreatment standard. E. City's Right of Revision. The city reserves the right to establish, by ordinance or in wastewater discharge permits, more stringent standards or requirements on discharges to the POTW. The city reserves the right to establish discharge limitation on pollutants not listed in the ordinance, if in the opinion of the city the pollutant(s) in question have the potential to have an adverse impact on the POTW. F. Dilution. No user shall ever increase the use of process water, or in any way attempt to dilute a discharge, as a partial or complete substitute for adequate treatment to achieve compliance with a discharge limitation unless expressly authorized by an applicable pretreatment standard or requirement. The city may impose mass limitations on users who are using dilution to meet applicable pretreatment standards or requirements, or in other cases when the imposition of mass limitations is appropriate.

(Ord. No. 1523, § 1, 1-22-13)

Ask a question about Rialto law

Corpus searches the Rialto sections it holds and shows the ones that match, with their citations. Free, no sign-in.