For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.56.040 — Material requirements

Municipal Code of the City of Rialto, California (Codified through Ordinance No. 1713, passed April 28, 2026. (Supp. No. 39)) · Rialto Municipal Code § 15.56.040

Corpus is an independent public-information project, not the official City of Rialto website. Stable reference: corpuslaw.us/code/a16a5150-e2f8-41c3-879a-a8f3d547c2f4

15.56.040 - Material requirements.

A. General. All materials permitted by this chapter, including their appropriate allowable design values and those existing configurations of materials specified herein, may be utilized to meet the requirements of this chapter. B. Existing Materials. All existing materials utilized as part of the required vertical load-carrying or lateral force-resisting system shall be in sound condition or shall be repaired or removed and replaced with new materials. C. Existing Unreinforced Masonry. 1. General. All unreinforced masonry walls utilized to carry vertical loads or seismic forces parallel and perpendicular to the wall plane shall be tested as specified in this subsection. All masonry that does not meet the minimum standards established by this chapter shall be removed and replaced with new materials or alternatively shall have its structural functions replaced with new materials and shall be anchored to supporting elements. 2. Lay-up of Walls. The facing and backing shall be bonded so that not less than ten percent of the exposed face area is composed of solid headers extending not less than four inches into the backing. The clear distance between adjacent full-length headers shall not exceed twenty-four inches vertically or horizontally. Where the backing consists of two or more wythes, the headers shall extend not less than four inches into the most distant wythe or the backing wythes shall be bonded together with separate headers whose area and spacing conform to the foregoing. Wythes of walls not bonded as described above shall be considered as veneer. Veneer wythes shall not be included in the effective thickness used in calculating the height to thickness and the shear capacity of the wall. 3. Location of Tests. The shear tests shall be taken at locations representative of the mortar conditions throughout the entire building, taking into account variations in workmanship at different building height levels, variations in weathering of the exterior surfaces, and variations in the condition of the interior surfaces due to deterioration caused by leaks and condensation of water and/or by the deleterious effects of other substances contained within the building. The exact test location shall be determined at the building site by the engineer in responsible charge of the structural design work. An accurate record of all such tests and their location in the building shall be recorded and these results shall be submitted to the building department for approval as part of the structural analysis. Verification by a structural engineer.

(Ord. 1250 § 1 (part), 1996)

Ask a question about Rialto law

Corpus searches the Rialto sections it holds and shows the ones that match, with their citations. Free, no sign-in.