§ 14.14.120: Grease interceptor maintenance requirements.

A. Grease interceptors shall be maintained in efficient operating condition by periodic removal of the full content of the interceptor, which includes wastewater, accumulated FOG, floating materials, sludge and solids. B. All grease interceptors shall be maintained in a manner consistent with the maintenance frequency approved by the director. C. All grease interceptors are required to have grease retention fittings as designed for proper function. Any interceptor that does not have the grease retention fittings shall be repaired and/or retro fitted with appropriate grease retention fittings. D. No FOG that has accumulated in a grease interceptor shall be allowed to pass into any sewer lateral, public sewer, storm drain or public right of way, or onto the surface of any street or parking area. E. The director may require any FSE with a grease interceptor to submit data and information necessary to establish the required maintenance frequency of the grease interceptor. F. The required maintenance frequency for every FSE with a grease interceptor shall be determined in one of the following methods: 1. Grease interceptors shall be fully pumped out and cleaned at a frequency such that the combined FOG and solids accumulation in the grease interceptor does not exceed 25 percent of the total designed hydraulic depth of the grease interceptor. This is to ensure that the minimum hydraulic retention time and required available hydraulic volume is maintained to effectively intercept and retain FOG from being discharged to the public sewer. 2. Every FSE with a grease interceptor shall fully pump out and clean its grease interceptor not less than once every six months. 3. Grease interceptors shall be fully pumped out and cleaned quarterly when the frequency described in Section 14.14.120(F)(1) has not been established. The maintenance frequency shall be adjusted when sufficient data have been obtained to establish an average frequency based on the requirements described in Section 14.14.120(F)(1) and guidelines adopted by the city pursuant to the FOG control program. The city may change the required maintenance frequency at any time to reflect changes in actual operating conditions in accordance with the FOG control program. Based on the actual generation of FOG from the FSE, the required maintenance frequency may increase or decrease. 4. The owner, operator or FOG WDP permittee of an FSE may submit a request to the director for a change in the required maintenance frequency at any time. The FSE has the burden of responsibility to demonstrate that the requested change in frequency reflects actual operating conditions based on the average FOG accumulation over time and meets the requirements described in Section 14.14.120(F)(1), and that it is in full compliance with the conditions of its FOG WDP and this chapter. Upon determination by the director that the requested revision is justified, the FOG WDP shall be revised accordingly to reflect the change in required maintenance frequency. 5. If the grease interceptor, at any time, contains FOG and solids accumulation exceeding the requirements described in Section 14.14.120(F)(1), the FSE shall be required to have the grease interceptor serviced immediately such that all FOG, and other materials are completely removed from the grease interceptor. If deemed necessary, the director may also increase the required maintenance frequency of the grease interceptor. G. Wastewater, accumulated FOG, floating materials, sludge/solids and other materials removed from the grease interceptor shall be disposed of by waste haulers at an approved disposal site in accordance with all applicable federal, state and/or local laws. H. The director may direct city staff to service an FSE's grease interceptor if, in the opinion of the director, the FSE has failed to comply with the terms of the FOG WDP or with this ordinance. The FSE shall be responsible for any and all expenses of the city in undertaking such work.

( Ord. 4683 § 1, 2008 )

Ask a question about Roseville law

Corpus searches the Roseville sections it holds and shows the ones that match, with their citations. Free, no sign-in.