Section 20.255.110 - Standards of Construction

Construction in all areas of special flood hazards shall comply with the standards set forth in this section. A. Anchoring. All new construction and substantial improvements of structures, including manufactured homes, shall be adequately anchored to prevent flotation, collapse, or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. B. Construction Materials and Methods. All new construction and substantial improvements of structures, including manufactured homes, shall be constructed as follows: 1. With flood-resistant materials and utility equipment resistant to flood damage. 2. Using methods and practices that minimize flood damage. 3. With electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. 4. Within Zone AH or AO so that there are adequate drainage paths around structures on slopes to guide flood waters around and away from proposed structures. C. Elevation and Floodproofing. 1. Residential Construction. All new construction or substantial improvements of residential structures shall have the lowest floor, including basement, as follows: a. In Zones AE, AH, and A1-30, elevated two (2) feet above the base flood elevation. b. In Zone AO, elevated above the highest adjacent grade to a height two (2) feet above the depth number specified in feet on the FIRM, or elevated at least four (4) feet above the highest adjacent grade if no depth number is specified. c. In Zone A, without base flood elevations specified on the FIRM (unnumbered Zone A), elevated two (2) feet above the base flood elevation, as determined under Section 20.255.090.C (Review, Use, and Development of other Base Flood Data). Upon completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered civil engineer or licensed land surveyor, and verified by the community building inspector, to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator. 2. Non-Residential Construction. All new construction or substantial improvements of any non-residential structures shall either be elevated to conform with Section 20.255.110.C.1 (Elevation and Floodproofing) or shall be as follows: a. Be floodproofed, together with attendant utility and sanitary facilities, below the elevation recommended under Section 20.255.110.C.1 (Elevation and Floodproofing), so that the structure is watertight, with walls substantially impermeable to the passage of water. b. Have structural components capable of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. c. Be certified by a registered civil engineer or architect that the standards of Sections 20.255.110.C.2.a and b (Elevation and Floodproofing) are satisfied. Such certification shall be provided to the Floodplain Administrator. 3. Flood Openings. All new construction and substantial improvements of structures with fully enclosed areas below the lowest floor (excluding basements) that are useable solely for parking vehicles, building access, or storage, and that are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of flood water. Designs for meeting this requirement must meet the following minimum criteria: a. For non-engineered openings: i. Have a minimum of two (2) openings having a total net area of not less than one (1) square inch for every one (1) square foot of enclosed area subject to flooding. ii. The bottom of all openings shall be no higher than one (1) foot above grade. iii. Openings may be equipped with screens, louvers, valves, or other coverings or devices, provided that they permit the automatic entry and exit of flood water. iv. Buildings with more than one (1) enclosed area must have openings on exterior walls for each area to allow flood water to directly enter. or b. Be certified by a registered civil engineer or architect. 4. Manufactured Homes. a. Manufactured homes located outside of manufactured home parks or subdivisions shall meet the elevation and floodproofing requirements of Section 20.255.110.C (Elevation and Floodproofing). b. Manufactured homes placed within manufactured home parks or subdivisions shall meet the standards in Section 20.255.140 (Standards for Manufactured Homes within Manufactured Home Parks or Subdivisions). Additional guidance may be found in FEMA Technical Bulletins TB 1-93 and TB 7-93. 5. Garages and Accessory Structures. a. Attached Garages i. A garage attached to a residential structure, constructed with the garage floor slab below the base flood elevation, must be designed to allow for the automatic entry of flood waters. See Section 20.255.110.C.3 (Elevation and Floodproofing). Areas of the garage below the base flood elevation must be constructed with flood-resistant materials. See Section 20.255.110.B (Construction Materials and Methods). ii. A garage attached to a non-residential structure must meet the above requirements or be dry floodproofed. b. Detached Garages and Accessory Structures i. Accessory structures used solely for parking (two (2)-car detached garages or smaller) or limited storage (small, low-cost sheds), as defined in Section 20.255.170 (Definitions), may be constructed such that its floor is below the base flood elevation, provided the structure is designed and constructed in accordance with all of the following requirements: a. Use of the accessory structure must be limited to parking or limited storage. b. The portions of the accessory structure located below the base flood elevation must be built using flood-resistant materials. c. The accessory structure must be adequately anchored to prevent flotation, collapse, and lateral movement. d. Any mechanical and utility equipment in the accessory structure must be elevated or floodproofed to or above the base flood elevation. e. The accessory structure must comply with floodplain encroachment provisions in Section 20.255.160 (Floodway). f. The accessory structure must be designed to allow for the automatic entry of flood waters in accordance with Section 20.255.110.C.3 (Elevation and Floodproofing). ii. Detached garages and accessory structures not meeting the above standards must be constructed in accordance with all applicable standards in Section 20.255.110 (Standards of Construction). 6. Crawlspace Construction. This sub-section applies to buildings with crawl spaces up to two (2) feet below grade. Below-grade crawl space construction in accordance with the requirements listed below will not be considered basements. a. The building must be designed and adequately anchored to resist flotation, collapse, and lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. Crawl space construction is not allowed in areas with flood velocities greater than five (5) feet per second unless the design is reviewed by a qualified design professional, such as a registered architect or professional engineer. b. The crawl space is an enclosed area below the base flood elevation and, as such, must have openings that equalize hydrostatic pressures by allowing for the automatic entry and exit of flood waters. c. Crawl space construction is not permitted in V Zones. Open pile or column foundations that withstand storm surge and wave forces are required in V Zones. d. Portions of the building below the base flood elevation must be constructed with materials resistant to flood damage. This includes not only the foundation walls of the crawl space used to elevate the building, but also any joists, insulation, or other materials that extend below the base flood elevation. e. Any building utility systems within the crawl space must be elevated above the base flood elevation or designed so that flood waters cannot enter or accumulate within the system components during flood conditions. f. Requirements for all below-grade crawl space construction, in addition to the above requirements, shall include the following: i. The interior grade of a crawl space below the base flood elevation must not be more than two (2) feet below the lowest adjacent exterior grade (LAG), shown as D in Figure 3 of Technical Bulletin 11-01. ii. The height of the below-grade crawl space, measured from the interior grade of the crawl space to the top of the crawl space foundation wall, must not exceed four (4) feet (shown as L in Figure 3 of Technical Bulletin 11-01) at any point. iii. There must be an adequate drainage system that removes floodwaters from the interior area of the crawl space within a reasonable period of time (not to exceed seventy-two (72) hours) after a flood event. iv. The velocity of floodwaters at the site shall not exceed five (5) feet per second for any crawl space. For velocities in excess of five (5) feet per second, other foundation types shall be used. 7. Mechanical Equipment. All new construction and substantial improvements of structures shall ensure that all mechanical equipment complies with the following criteria: a. The mechanical equipment shall be elevated above the base flood elevation, or b. the mechanical equipment shall be designed or located in such a way as to prevent water from entering or accumulating within the components during a flood event.

Ask a question about San Marcos law

Corpus searches the San Marcos sections it holds and shows the ones that match, with their citations. Free, no sign-in.