8.56.320 - Minimum Requirements for Septic Tanks.

Any septic tank hereafter constructed or installed in the City, shall meet the following minimum specifications: (a) Such tank shall have an inside diameter of at least five feet with a liquid depth of at least four feet. The length of the tank shall not exceed three times the width of such tank. Such tank shall have a liquid capacity of not less than 1,000 gallons. Such tank shall have at least two compartments, and a manhole with a minimum diameter or width of 22 inches shall be installed in each compartment, over the inlet and outlet pipe. (b) The inlet and the outlet of such tank shall each be a vertical four-inch diameter "T" extending such a distance below the liquid level that 40 percent of the liquid depth is below it, and extending a minimum of six inches above the liquid level of the tank. The outlet shall be two inches below the inlet. (c) Such tank shall be watertight and shall be constructed of concrete, concrete block, brick or tile. The top of such tank shall be constructed of reinforced concrete at least four inches thick. When such tank is constructed, the walls and bottom of the tank shall be at least six inches thick and shall be adequately reinforced with steel or other approved material. The concrete used for such tanks shall contain one part cement, two parts sharp sand and four parts crushed rock or gravel. Where brick, concrete block, or tile is used in the construction of such tank, the inside shall be plastered with Portland cement mortar composed of one part cement and three parts sand. The side walls of such tank shall be adequately reinforced with steel or other approved material so as to withstand any inside or outside pressure. The Director may approve alternative materials and construction specifications to meet health requirements. (d) The line from such septic tank to the distribution box or leach field shall be constructed of watertight bell and spigot pipe, or such other pipe with watertight joints that the Director may approve.

Ask a question about San Marcos law

Corpus searches the San Marcos sections it holds and shows the ones that match, with their citations. Free, no sign-in.