§ 10.06.050 — Provisions for Flood Hazard Reduction

Municipal Code, City of Santa Clarita, California (Santa Clarita Municipal Code current through legislation adopted 09-08-2026 (eCode360 publication SA4627, scraped 2026-11-18)) · Santa Clarita Municipal Code § 10.06.050

Corpus is an independent public-information project, not the official City of Santa Clarita website. Stable reference: corpuslaw.us/code/e4217124-949b-477d-a314-fefee1d6782c

§ 10.06.050: Provisions for Flood Hazard Reduction.

A. Standards of Construction. In all areas of special flood hazards the following standards are required: 1. Anchoring. All new construction and substantial improvements of structures, including manufactured homes, shall be adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. 2. Construction Materials and Methods. All new construction and substantial improvements of structures, including manufactured homes, shall be constructed: a. With flood-resistant materials as specified in FEMA Technical Bulletin TB 2 and all subsequent revisions and utility equipment resistant to flood damage for all areas below the level of the base flood elevation plus one (1) foot; b. Using methods and practices that minimize flood damage; c. With electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; and d. Within Zones AH or AO, so that there are adequate drainage paths around structures on slopes to guide flood waters around and away from proposed structures. 3. Elevation and Floodproofing. (See definitions for "basement," "lowest floor," "new construction," "substantial damage" and "substantial improvement.") a. Residential Construction. All new construction or substantial improvements of residential structures shall have the lowest floor, including basement: i. In AE, AH, A1-A30 Zones, elevated to at least one (1) foot above the base flood elevation; ii. In an AO Zone, elevated above the highest adjacent grade to a height exceeding the depth number specified in feet on the FIRM by at least one (1) foot, or elevated at least three (3) feet above the highest adjacent grade if no depth number is specified; and iii. In an A Zone, without BFEs specified on the FIRM (unnumbered A Zone), elevated at least one (1) foot above the base flood elevation, as determined by Section 10.06.040(B)(3). Upon the completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered civil engineer or licensed land surveyor, and verified by the community building inspector to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator. b. Nonresidential Construction. All new construction or substantial improvements of nonresidential structures shall either be elevated to conform with subsection (A)(3)(a) of this section or: i. Be floodproofed, together with attendant utility and sanitary facilities, below the elevation recommended under subsection (A)(3)(a) of this section, so that the structure is watertight with walls substantially impermeable to the passage of water; ii. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and iii. Be certified by a registered professional civil engineer or licensed land surveyor that the standards of subsection (A)(3)(b)(i) and (ii) of this section are satisfied. Such certification shall be provided to the Floodplain Administrator. c. Flood Openings. All new construction and substantial improvements of structures with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement must exceed the following minimum criteria: i. For nonengineered openings: (A) Have a minimum of two (2) openings on different sides having a total net area of not less than one (1) square inch for every one (1) square foot of enclosed area subject to flooding; (B) The bottom of all openings shall be no higher than one (1) foot above grade; (C) Openings may be equipped with screens, louvers, valves or other coverings or devices; provided, they permit the automatic entry and exit of flood water; and (D) Buildings with more than one (1) enclosed area must have openings on exterior walls for each area to allow flood water to directly enter; or ii. Be certified by a registered professional civil engineer or architect. d. Manufactured Homes. i. Manufactured homes located outside of manufactured home parks or subdivisions shall meet the elevation and floodproofing requirement in subsection (A)(3) of this section. ii. Manufactured homes placed within manufactured home parks or subdivisions shall meet the standards in subsection (D) of this section. Additional guidance may be found in FEMA Technical Bulletins TB 1, TB 7-93, and all subsequent revisions. e. Garages and Low-Cost Accessory Structures. i. Attached Garages. (A) A garage attached to a residential structure, constructed with the garage floor slab below the BFE, must be designed to allow for the automatic entry of floodwaters. See subsection (A)(3) of this section. Areas of the garage below the level of the base flood elevation plus one (1) foot must be constructed with flood resistant materials. See subsection (A)(2) of this section. (B) A garage attached to a nonresidential structure must meet the above requirements. For guidance on below grade parking areas, see FEMA Technical Bulletin TB 6-93 and all subsequent revisions. ii. Detached Garages and Accessory Structures. (A) Accessory structures used solely for parking (two (2) car detached garages or smaller) or limited storage (small, low-cost sheds), as defined in Section 10.06.020, may be constructed such that its floor is below the base flood elevation (BFE), provided the structure is designed and constructed in accordance with the following requirements: (1) Use of the accessory structure must be limited to parking or limited storage; (2) The portions of the accessory structure located below the level of the base flood elevation plus one (1) foot must be built using flood-resistant materials; (3) The accessory structure must be adequately anchored to prevent flotation, collapse and lateral movement; (4) Any mechanical and utility equipment in the accessory structure must be elevated or floodproofed to at least one (1) foot above the BFE; (5) The accessory structure must comply with floodplain encroachment provisions in subsection (F) of this section; and (6) The accessory structure must be designed to allow for the automatic entry and exit of floodwaters in accordance with subsection (A)(3)(c) of this section. (B) Detached garages and accessory structures not meeting the above standards must be constructed in accordance with all applicable standards of this subsection (A). B. Standards for Utilities. 1. All new and replacement water supply and sanitary sewage systems shall be designed to minimize or eliminate: a. Infiltration of floodwaters into the systems; and b. Discharge from the systems into floodwaters. 2. On-site waste disposal systems shall be located to avoid impairment to them, or contamination from them, during flooding. C. Standards for Subdivisions and Other Proposed Development. 1. All new subdivision proposals and other proposed development, including proposals for manufactured home parks and subdivisions, greater than fifty (50) lots or five (5) acres, whichever is the lesser, shall: a. Identify the special flood hazard areas (SFHAs) and base flood elevations (BFEs); b. Identify the elevations of lowest floors of all proposed structures and pads on the final plans; and c. If the site is filled above the base flood elevation, the following as-built information for each structure shall be certified by a registered professional civil engineer or licensed land surveyor and provided as part of an application for a letter of map revision based on fill (LOMR-F) to the Floodplain Administrator: i. Lowest floor elevation. ii. Pad elevation. iii. Lowest adjacent grade. 2. All subdivision proposals and other proposed development shall be consistent with the need to minimize flood damage. 3. All subdivision proposals and other proposed development shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage. 4. All subdivisions shall provide adequate drainage to reduce exposure to flood hazards. D. Standards for Manufactured Homes Within Manufactured Home Parks and Subdivisions. All manufactured homes in special flood areas shall meet the anchoring standards in subsection (A)(1) of this section, construction materials and methods in subsection (A)(2) of this section, flood opening requirements in subsection (A)(3)(c) of this section, and garage and low-cost accessory structure standards in subsection (A)(3)(e) of this section. Note: Manufactured homes located outside of manufactured home parks or subdivisions shall meet the elevation and floodproofing requirements in subsection (A)(3) of this section. 1. All manufactured homes that are placed, or substantially improved, on sites located in a new manufactured home park or subdivision, in an expansion to an existing manufactured home park or subdivision, or in an existing manufactured home park or subdivision on a site upon which a manufactured home has incurred substantial damage as the result of a flood shall: a. Within Zones A, AO, A1-30, AH, and AE on the community's Flood Insurance Rate Map, be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated to at least one (1) foot above the base flood elevation and be securely fastened to an adequately anchored foundation system to resist flotation, collapse and lateral movement. 2. All manufactured homes to be placed or substantially improved on sites in an existing manufactured home park or subdivision within Zones A, AO, A1-30, AH, and AE on the community's Flood Insurance Rate Map that are not subject to the provisions of subsection (D)(1) of this section will be securely fastened to an adequately anchored foundation system to resist flotation, collapse, and lateral movement, and be elevated so that either the: a. Lowest floor of the manufactured home is at least one (1) foot above the base flood elevation; or b. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than thirty-six (36) inches in height above grade. Upon the completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered civil engineer or licensed land surveyor, and verified by the community building inspector to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator. E. Standards for Recreational Vehicles. 1. All recreational vehicles placed on sites within Zones A, AO, A1-30, AH, and AE on the community's Flood Insurance Rate Map will either: a. Be on the site for fewer than one hundred eighty (180) consecutive days; b. Be fully licensed and ready for highway use. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick-disconnect type utilities and security devices, and has no permanently attached additions; or c. Meet the permit requirements of Section 10.06.040(C) and the elevation and anchoring requirements for manufactured homes in subsection (D)(1) of this section. F. Floodways. Since floodways are extremely hazardous areas due to the velocity of floodwaters which carry debris, potential projectiles, and erosion potential, the following provisions apply: 1. Until a "regulatory floodway" is adopted, no new construction, substantial development or other development (including fill) shall be permitted within Zones A, AO, A1-30 and AE, unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other development, will not increase the water surface elevation of the base flood more than one (1) foot at any point within the City of Santa Clarita. 2. Within an adopted regulatory floodway, the City of Santa Clarita shall prohibit encroachments or obstructions, including fill, new construction, substantial improvements and other development, unless certification by a registered professional civil engineer is provided demonstrating that the proposed encroachments or obstructions shall not result in any increase in the base flood levels during the occurrence of the base flood discharge. 3. If subsections (F)(1) and (2) of this section are satisfied, all new construction, substantial improvement, and other proposed new development shall comply with all other applicable flood hazard reduction provisions of this section. G. Cumulative Substantial Improvement and Substantial Damage. 1. Improvements of any type or value to structures located in areas of special flood hazard, constructed on or after April 25, 1980, must meet all floodproofing requirements of this chapter. 2. Improvements valued up to forty-nine percent (49%) of an existing structure's pre-improvement market value, located in areas of special flood hazard, constructed prior to April 25, 1980, may be permitted without meeting the flood protection requirements of this chapter. Once the substantial improvement or substantial damage threshold of greater than forty-nine percent (49%) has been reached: a. No further building permits will be issued for the structure for a period of one (1) year from the date of the issuance of the first building permit for improvements, alterations or additions, rehabilitations or repairs, regardless of the origin of the damage, or any combination of said improvements unless the structure is made to comply with the requirements of this chapter; b. When the total value of the cumulative improvements meets or exceeds fifty percent (50%) of a structure's pre-improvement market value within a one (1) year period, the original structure must be protected according to the requirements of this chapter; and c. The market value of the structure used at the issuance of the first building permit is the market value that will be used throughout the one (1) year period to determine the cost percentage of the proposed improvements.

( Ord. 97-11 , 7/8/1997 ; Ord. 08-11 § 2, 8/26/2008 ; Ord. 13-6 § 4 (Exh. C), 5/28/2013 ; Ord. 19-11 § 3, 11/26/2019 ; Formerly 10.06.040 )

Ask a question about Santa Clarita law

Corpus searches the Santa Clarita sections it holds and shows the ones that match, with their citations. Free, no sign-in.