§ 13.18.040 — Underground Pipelines—Minimum Depth of Cover
Municipal Code, City of Santa Clarita, California (Santa Clarita Municipal Code current through legislation adopted 09-08-2026 (eCode360 publication SA4627, scraped 2026-11-18)) · Santa Clarita Municipal Code § 13.18.040
Corpus is an independent public-information project, not the official City of Santa Clarita website. Stable reference: corpuslaw.us/code/90c75959-6499-4fd7-a92f-cda949a0bb41
§ 13.18.040: Underground Pipelines—Minimum Depth of Cover.
Except as provided in Section 13.18.041, the following minimum depths of cover below existing finished or proposed gutter grade shall be required for all underground pipelines within the roadway area: A. Local Streets. Twenty-four (24) inches for service pipelines; 30 inches for all pipelines transporting non-hazardous substances; 30 inches for electrical facilities; 42 inches for all pipelines transporting hazardous substances as defined in Section 13.04.080. B. Master Plan Highways. 24 inches for service pipelines; 36 inches for pipelines transporting non-hazardous substances; 42 inches for electrical facilities; 42 inches for pipelines transporting hazardous substances, as defined in Section 13.04.080.
( Ord. 89-20 , 8/8/1989 )