§ 13.18.070 — Pipelines Carrying Hazardous Substances—Cathodic Protection System Required—Specifications

Municipal Code, City of Santa Clarita, California (Santa Clarita Municipal Code current through legislation adopted 09-08-2026 (eCode360 publication SA4627, scraped 2026-11-18)) · Santa Clarita Municipal Code § 13.18.070

Corpus is an independent public-information project, not the official City of Santa Clarita website. Stable reference: corpuslaw.us/code/82f46c62-99fc-4ce8-91e3-cc1f42fcabe8

§ 13.18.070: Pipelines Carrying Hazardous Substances—Cathodic Protection System Required—Specifications.

As provided in the American National Standard Institute's Code for Pressure Piping, Liquid Petroleum Transportation Piping Systems (ANSI B 31.4) in its latest revision, a cathodic protection system shall be installed for all new ferrous pipelines used to carry toxic, corrosive or flammable substances other than utility gases in order to mitigate corrosion deterioration that might result in structural failure. The cathodic protection system for all new ferrous pipelines carrying utility gases shall be installed in accordance with General Order No. 112-C of the Public Utilities Commission of the state of California. A test procedure shall be developed by the owner or operator to determine whether adequate cathodic protection has been achieved and submitted to the Director for approval. Reports of cathodic protection evaluation in accordance with such approved procedure shall be made available annually for review by the Director.

( Ord. 89-20 , 8/8/1989 )