§ 17.51.050 — Outdoor Lighting Standards
Municipal Code, City of Santa Clarita, California (Santa Clarita Municipal Code current through legislation adopted 09-08-2026 (eCode360 publication SA4627, scraped 2026-11-18)) · Santa Clarita Municipal Code § 17.51.050
Corpus is an independent public-information project, not the official City of Santa Clarita website. Stable reference: corpuslaw.us/code/5553feff-0175-4e39-85a7-41770825da16
§ 17.51.050: Outdoor Lighting Standards.
A. Purpose. These regulations are intended to: 1. Permit reasonable uses of outdoor lighting for night-time safety, utility, security, productivity, enjoyment, and commerce. 2. Conserve energy and resources to the greatest extent possible. 3. Minimize adverse off-site light trespass and/or obtrusive light. 4. Reduce light pollution and preserve the nighttime environment. 5. Protect the natural environment and the general public health, safety and welfare from the adverse effects of excessive night lighting from electric sources. B. Applicability. 1. New Lighting. Unless otherwise expressly stated, this section shall apply to all new outdoor lighting. Outdoor lighting includes, but is not limited to, all lighting fixtures attached to buildings, structures, poles, or self-supporting structures and may be found on parking lots, walkways, building entrances, outdoor or exterior sales areas, landscaping, recreational fields, and building facades. 2. Replacement Lighting. Unless otherwise expressly stated, the standards of this section apply whenever additions or replacements to existing outdoor lighting are installed, including upgrades and/or replacements to damaged or destroyed fixtures. C. Exemptions. The following lighting fixtures and systems shall be exempt from the requirements of this section: 1. Lighting fixtures within the public right-of-way. 2. Lighting required by a health or life safety statute, ordinance, or regulation, including, but not limited to, emergency lighting required by the Occupational Safety and Health Administration. 3. Temporary lighting used by law enforcement or emergency services personnel to protect life or property. 4. Temporary lighting used for the construction or repair of roadways, utilities, and other public infrastructure. 5. Lighting used in, or for the purpose of, lighting swimming pools, hot tubs, decorative fountains, and other water features, subject to Article 680 of the California Electrical Code. 6. Temporary lighting for activities permitted by a temporary use permit. 7. Sign lighting (refer to Section 17.51.080 (Sign Regulations (Private Property))). 8. All outdoor light fixtures producing light directly by combustion of fossil fuels, such as kerosene lanterns, tiki torches, or gas lamps. 9. Spotlights and flood lighting is permitted for the purpose of emphasizing architectural accents or details on buildings, sculptures, or landscaping, as long as such lighting does not create light trespass or obtrusive light. Such lighting shall be prohibited between the hours of midnight and sunrise if projected above the horizon. 10. Lighting for public and/or private facilities which are thirty-five (35) feet in height or less including but not limited to prisons, airports, sports fields/playfields, helipads/heliports, and hospitals. 11. Lighting for public facilities including, but not limited to, sports fields/playfields, community centers and other facilities for public assembly, that are owned and operated by the City of Santa Clarita and that exceed thirty-five (35) feet in height shall be subject to an administrative permit (refer to Section 17.23.100 (Administrative Permit)) and be subject to lighting standards provided for in subsection (D) of this section with a further requirement for a photometric study and renderings of the project. D. Lighting Standards. 1. General Requirements. a. Shielding. All lighting shall be directed downward and be of a cut-off design so the luminary and/or lens do not protrude below the luminary housing and is not visible from a public right-of-way. b. Light Trespass. Lighting may not illuminate other properties and shall be directed downward to prevent off-site glare. c. Appurtenances. Lighting shall be operated so that they do not disturb the peace, quiet, and comfort of adjacent, neighboring uses, and shall be screened and/or shielded from surrounding properties and streets. d. Lighting Plan. Except for new and additions to single-family residences, applications for new buildings and building additions, and proposed modifications shall include the location, fixture type, fixture height, and photometric information of all outdoor lighting and information about shut-off timers and hours of operation for outdoor lighting where required by this section for review and approval by the Director. 2. Requirements for Commercial, Industrial, and Mixed Uses. All lighting shall comply with the following: a. Building Entrance Lighting. All building entrances shall install light fixtures that provide accurate color rendition so that persons entering or exiting the establishment can be easily recognized. Building entrance lighting shall be used between sundown and ten p.m. or one (1) hour past the close of the business, whichever is later. b. Hours of Operation. i. Outdoor lighting shall be turned off between the hours of ten p.m. and sunrise, except where uses operate past ten p.m., lighting shall be turned off one (1) hour after the close of business or use dimmers per subsection (D)(2)(b)(ii)(C) of this section. ii. All outdoor lighting systems shall install one (1) or more of the following: (A) Automatic time switch controls used to turn lighting off after ten p.m.; (B) Motion sensors used to turn on lighting after ten p.m. when activity is detected. Such lighting shall remain on no longer than ten (10) minutes after being activated; or (C) In lieu of turning lighting off, automatic dimmers used to reduce light levels by a minimum of fifty percent (50%) after ten p.m. iii. Exemptions. (A) Code required lighting for steps, stairs, walkways, and points of ingress and egress to building and other facilities. (B) Lighting governed by a discretionary use permit in which times of operation are specifically identified. 3. Requirements for Residential Sports Courts. a. Outdoor lighting for residential sports courts shall comply with the standards as set forth in Section 17.57.040 (Accessory Buildings and Structures). 4. Prohibitions. The following lighting fixtures and systems shall be prohibited: a. Drop down lenses; b. Mercury vapor lamps; c. Searchlights, laser lights, or any other lighting that flashes, blinks, alternates, or moves. 5. Maintenance. Outdoor lighting fixtures and lamps shall be maintained in good working order. 6. Modifications. Modifications to the standards in this section shall be approved through Section 17.24.120 (Minor Use Permit).
( Ord. 13-8 § 4 (Exh. A), 6/11/2013 ; Ord. 22-9 § 5 (Exh. A), 7/12/2022 )
Ask a question about Santa Clarita law
Corpus searches the Santa Clarita sections it holds and shows the ones that match, with their citations. Free, no sign-in.
