§ 18.02.030: Section 105.2 is Amended.
Section 105.2 is amended to read as follows: 105.2 Work Exempted from Permit. Exemptions from the permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of the City of Santa Clarita including such requirements as may be established by any city department or division or the requirements of any other governing agency. Unless otherwise exempted, separate plumbing, electrical, and mechanical permits will be required for any such items exempted herein. Permits shall not be required for the following: Building: 1. One-story detached light-framed structures accessory to a Group R-3 or U occupancy used as tool and storage sheds, playhouses, trellis structures, gazebos, arbors, greenhouses and similar uses where the gross floor area does not exceed 120 square feet as measured to the outside walls or support posts and the structure complies with all of the following conditions: a. The floor is not more than 30 inches above the adjoining grade, b. The overall height is not more than 14 feet as measured from adjacent grade, c. The structure is not constructed on a slope steeper than 3:1, d. The structure is not within a flood hazard or floodplain, e. The structure has no permanent heating or air-conditioning, f. The location of the structure is approved by the city's Planning Division. Notes: 1) | Storage or tool sheds over 120 square feet but not exceeding 250 square feet in area that meet the above conditions may be constructed under a 'foundation only' permit. Such permit may include the installation of one 20 Amp branch circuit, (1) light fixture and one (1) 110/115 V. GFCI outlet. 2) | It is permissible that these structures still be regulated by the California Wildland-Urban Interface Code despite exemption from permit. 2. Where allowed by the city's Planning Division, chain link or wire fences not over 12 feet in height, wood, vinyl, or open wrought iron fences not over 6 feet in height, and block walls or pilasters not over 42 inches in height where not constructed within a flood hazard or floodplain, or as part of a swimming pool barrier. 3. Sidewalks and driveways which are not more than 30 inches above adjacent grade and not over any basement or story below, and are not part of an accessible route as required per Chapter 11A or 11B of this code. 4. Decks or platforms accessory to a Group R-3 or U occupancy that are not more than 30 inches above adjacent grade or constructed over a slope or in a flood hazard or floodplain. 5. Exterior hardscape features such as patios, seating walls, walkways, stepped walks or stairs integrated in a slope, koi ponds, fountains or similar water features not over 18 inches in depth, raised planters and similar hardscape features that are accessory to a Group R-3 or U occupancy. 6. Canopies, awnings, or open trellises that do not extend more than 36 inches from the exterior wall of a building or, if attached to a Group R, Division 3, or Group U occupancy, do not extend more than 54 inches and are not within 3 feet of the property line. 7. Retaining walls that are not over 4 feet in height measured from the bottom of the footing to the top of the wall, or where supporting a slope or surcharge, not more than 30 inches in height measured from bottom of footing to the top of the wall. For 'dry stacked' interlocking retaining wall systems such as 'keystone walls' the maximum exempt height is 36 inches above the lowest adjacent grade or 18 inches where supporting a slope or surcharge. This exemption does not apply to retaining walls constructed on a slope steeper than 3:1, located in a floodplain, or impounding Class I, II or IIIA liquids. 8. Fixed or moveable cases, racks, shelving, and partitions not exceeding 6 feet in height. The installation of such elements shall not reduce aisle widths, clearances or means of egress to less than that required by this code. 9. The installation of decorative moldings, trim, window treatments, wall coverings, painting, papering, tiling, carpeting, hardwood or tile flooring, counters or countertops, tub or shower surrounds and similar interior finish work. Notwithstanding, all such materials and work shall comply with applicable provisions of Chapter 8 of this code for allowable materials, combustibility and fire performance. 10. Garage and closet organizers, cabinets, or shelving not exceeding 8 feet in height within a Group R-3 or U occupancy. 11. Drywall within Group U occupancies not required to be part of a fire rated assembly. 12. The installation of replacement window units where installed within existing frames and where no stucco or siding is removed, provided the following conditions are met: a. The net opening area of the existing window(s) is not reduced to less than that required by this code for light and ventilation. b. Any required egress (emergency escape) window is replaced with an egress (emergency escape) window complying with this code. c. The provisions of this code for safety glazing are met. 13. Satellite dishes not exceeding 30 inches in diameter where attached to a structure, or 36 inches in diameter where ground mounted and not exceeding 15 feet in height. 14. Radio or television antennae towers where ground mounted and not exceeding 30 feet in height. 15. Light standards which do not exceed 20 feet in height (electrical permits are required). 16. Flagpoles not exceeding 20 feet in height where not attached to or erected on any building or structure. 17. Prefabricated swimming pools or spas accessory to a Group R-3 occupancy provided that: a. The capacity does not exceed 5,000 gallons. b. The pool or spa is not constructed on a slope greater than 3:1. c. The lowest point of the bottom of the pool or spa is not more than 24 inches below adjacent grade. d. The pool or spa is provided with a safety barrier as required in the California Health & Safety Code. An electrical permit is required for any permanently connected pumps or motors. 18. Removal and replacement of the plaster finish of a swimming pool or spa accessory to a Group R-3 occupancy provided that: a. No mechanical, electrical, or plumbing elements are being added, altered, or removed. b. The swimming pool or spa is equipped with at least two of the drowning prevention safety features listed in Health and Safety Code section 115922. c. The pool or spa is equipped with anti-entrapment grates as specified in Health and Safety Code section 115928.5. 19. Structures or equipment accessory to a Group R occupancy which are intended solely for play or amusement, and which are clearly identifiable as play or amusement structures as determined by the Building official, and which are no more than 14 feet in height above adjacent grade. These structures may include, but are not limited to: swings, slides, climbing structures and similar playground equipment, skateboard or bike ramps, pool slides whether built-in or free standing, basketball standards, tennis or sports courts (not including fencing or lighting), and similar structures. Notwithstanding, such structures must comply with all applicable zoning standards for use and location. Where a permanently constructed pool slide or other landscape feature also serves as part of a retaining wall, such portions of the construction that act as a retaining wall require a permit unless specifically exempted herein. An electrical permit is required for any permanently connected lighting or other electrical equipment. 20. Tree houses provided that: a. The floor area does not exceed 64 square feet; b. The ceiling height does not exceed 6 feet; c. The tree house is not constructed in an oak tree. d. The tree house does not have mechanical, electrical, or plumbing elements. 21. Temporary sheds, construction trailers, and other structures incidental to work authorized by a valid grading or building permit. Electrical and plumbing permits are required when there are any such connections associated with the temporary shed or construction trailer. Any such structure shall be removed upon completion of the work covered by the permit or expiration of the permit. 22. Tents, inflatable structures, and similar canopy structures, where used in conjunction with a special event, that are open on at least three sides and do not exceed 500 square feet in projected area, or where enclosed on two or more sides, that do not exceed 300 square feet in enclosed area. Notwithstanding, all such structures shall be adequately anchored to resist local wind forces. 23. Temporary stages or platforms that do not exceed 30 inches in height that are used in conjunction with a special event. 24. Shade cloth structures constructed solely for nursery or agricultural purposes, not including service systems within such structures. 25. Temporary motion picture, television, and theater stage sets and scenery. 26. Gantry cranes and similar equipment. 27. Prefabricated water tanks supported directly on grade where the capacity does not exceed 5,000 gallons and the ratio of height to the diameter or width does not exceed one and one-half to one (1 1/2:1). 28. The following work when conducted in association with an operating oil field: a. Oil derricks; b. Installation and relocation of process vessels and tanks; c. Construction, installation and relocation of process piping and pipe supports; d. Construction, installation and relocation of ladders, stairs, and catwalks; e. Installation of foundations for process vessels, pipe supports, generators, tanks, pumps, and uninhabited buildings located more than 20 feet from any property line; f. Construction, installation, and relocation of uninhabited buildings; g. Road maintenance; h. Grading of new and existing well pads, provided the grading does not affect an adjoining property; i. Grading and construction for erosion control, provided it does not affect an adjoining property; j. Debris basin maintenance; (Note: The waiver of a building permit shall not be deemed as a waiver from the oil field operator from obtaining the required clearances from other public agencies.) Electrical: Note: refer to the 2025 California Electrical Code with local amendments for additional exemptions 1. | Low-voltage wiring for security systems, telephone or other communication systems, door bells, intercom or sound systems, television cable, and similar installations within a Group R-3 or U occupancy. 2. | Electrical equipment used for commercial radio and television transmitting stations, excluding any equipment or wiring for the power supply to any such station. Mechanical Note: refer to the 2025 California Mechanical Code with local amendments for additional exemptions. 1. | Portable equipment including heating appliances, ventilation equipment, air-conditioning or evaporative cooling units. 2. | Self-contained refrigeration systems containing 10 pounds or less of refrigerant and actuated by motors of 1 horsepower or less.
( Ord. 25-5 , 11/25/2025 )
Ask a question about Santa Clarita law
Corpus searches the Santa Clarita sections it holds and shows the ones that match, with their citations. Free, no sign-in.