For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.02.230 — Section 118 is Added

Municipal Code, City of Santa Clarita, California (Santa Clarita Municipal Code current through legislation adopted 09-08-2026 (eCode360 publication SA4627, scraped 2026-11-18)) · Santa Clarita Municipal Code § 18.02.230

Corpus is an independent public-information project, not the official City of Santa Clarita website. Stable reference: corpuslaw.us/code/f28f9798-309c-42e5-a093-e8410a94cb2f

§ 18.02.230: Section 118 is Added.

Section 118 is added to read as follows: Section 118 Fire Hazard Zones ("Fire Hazard Severity Zones"). 118.1 General. For the purpose of this code, Fire Hazard Zones are those areas in the City of Santa Clarita that have been designated as fire hazard zones by the California Department of Forestry and Fire Protection and are shown on the city's Geographic Information System (GIS) on a layer identified with the words "Fire Zone." Such map is declared to be a part of this code and effective on the date of designation by the city. 118.2 Scope. The provisions of this section shall apply to new construction on individual lots or parcels that are located in a Fire Hazard Zone for which an application for a permit is submitted. 118.3 Construction requirements for buildings or structures in the Fire Hazard Zone. 118.3.1 General. Any building or structure hereafter erected, constructed, altered, added onto, or moved within or into a Fire Hazard Zone shall comply with all applicable provisions of the California Wildland-Urban Interface Code (CWUIC) as adopted by the City of Santa Clarita. 118.3.2 Roof covering repair or replacement. Roof covering on an existing building or structure that is being repaired or replaced shall comply with Chapter 15 of this code, as amended. 118.3.3 Exterior wall covering of existing buildings. Where the exterior wall covering of an existing building or structure is being repaired or replaced and the cumulative area being repaired or replaced is greater than 50 percent of the total existing wall area, both the new and existing wall covering shall comply with the provisions of the CWUIC in their entirety. The provisions of this section shall be cumulative over any one-year period. 118.3.4 Exterior windows and doors of existing buildings. Where exterior windows and/or doors of an existing building are being replaced with new windows and/or doors, and where the number of windows and/or doors being replaced is greater than 50 percent of the total number of windows and/or doors on the building, all windows and/or doors on the building shall comply with the CWUIC. The provisions of this section shall be cumulative over any one-year period.

( Ord. 25-5 , 11/25/2025 )

Ask a question about Santa Clarita law

Corpus searches the Santa Clarita sections it holds and shows the ones that match, with their citations. Free, no sign-in.