For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 20-23.040 — Commercial district general development standards

Code of Ordinances, City of Santa Rosa, California (Code 2026-09-15: eCode360 publication current through Ord. No. 2026-014 adopted September 15, 2026 (scraped 2026-11-20)) · Santa Rosa Code of Ordinances § 20-23.040

Corpus is an independent public-information project, not the official City of Santa Rosa website. Stable reference: corpuslaw.us/code/3b0e77fb-8c5b-448e-9de9-e13e078caee1

§ 20-23.040: Commercial district general development standards.

A. General requirements. Subdivisions, new land uses and structures, and alterations to existing land uses and structures, shall be designed, constructed, and/or established in compliance with the requirements in Tables 2-7 and 2-8, in addi-tion to the applicable development standards (e.g., landscaping, parking and loading, etc.) in Division 3 of this Zoning Code. B. Modifications to standards. The requirements of Tables 2-7 and 2-8 may be modified by the Commission through Conditional Use Permit approval. C. Design Guidelines. See also Sections 2 (Core Area), 3.3 (Retail Centers and Commercial Districts) and 4.3 (Infill Development) of the City's Design Guidelines. TABLE 2-7—CO, CN, AND CG DISTRICT DEVELOPMENT STANDARDS Requirement by Zoning District Development Feature | CO | CN | CG Minimum lot size | Minimum area and dimensions for parcels proposed in new subdivisions. Area (1) | 6,000 sf—Interior lot7,000 sf—Corner lot | None required | Determined by CUP Dimensions (1) | None required Residential density | Maximum number of dwelling units allowed on a parcel. The actual number of units will be determined by the City through subdivision or land use permit approval. Maximum or required density | 30 units per acre, maximum | 1 unit required per 4,000 sf of non-residential use, to a max. 30 units per acre | 30 units per acre, maximum Setbacks (1) (2) | Minimum setbacks required. See Section 20-30.110 for setback measurement instructions. Front | 15 ft | 7.5 ft adjacent to a residential zone or use, or more as required by Design Review; none required elsewhere Side—Interior (each) | 5 ft | 5 ft adjacent to a residential zone or use, or more as required by Design Review; none required elsewhere Side—Corner | 15 ft Rear | 1-story building—5 ft2-story building—10ft;15 ft adjacent to R zone3 or more stories—15 ft 25 ft adjacent to R zone | 10 ft adjacent to a residential zone or use, or more as required by Design Review; none required elsewhere Lot coverage (1) | Maximum percentage of total lot area that may be covered by structures. Maximum coverage | 65% | 85% for retail/service uses other than lodging;65% for recreation, education, public assembly, lodging, public buildings and utilities | 100% Height limit | Maximum allowable height of structures. See Section 20-30.070 (Height Limits and Exceptions) for height measurement requirements, and height limit exceptions. Maximum height | 35 ft | 45 ft | 55 ft Landscaping | See Chapter 20-34 (Landscaping Standards) Parking | See Chapter 20-36 (Parking and Loading) Signs | See Chapter 20-38 (Signs) Notes: (1) | Subdivision or Conditional Use Permit approval may establish specific requirements for minimum lot area, maximum lot coverage, set backs, and/or dimensions based on the characteristics of the site or surroundings, environmental constraints, and/or other issues. (2) | The Design Review process may require larger setbacks. TABLE 2-8—CV, CMU, SMU, MMU, NMU, AND CSC DISTRICT DEVELOPMENT STANDARDS Development Feature | Requirement by Zoning District CV | CMU(4) | SMU(4) | MMU(4) | NMU(4) | CSC Minimum lot size | Minimum area and dimensions for parcels proposed in new subdivisions. Area | 20,000 sf | None required | None required | None required | None required | Determined by CUP Dimensions | None required (1) | None required (1) | None required (1) | None required (1) | None required (1) | None required (1) Residential density | Maximum number of dwelling units allowed on a parcel. The actual number of units will be determined by the City through subdivision or land use permit approval. Maximum density | Not allowed | See FAR Section 20.23.060. None required for parcels without an assigned FAR. | See FAR Section 20-23.060. | See FAR Section 20-23.060. | See FAR Section 20-23.060. | 1 unit required per 4,000 sf of nonresidential floor area to a maximum of 30 units per acre. Setbacks (1) (2) | Minimum setbacks required. See Section 20-30.110 for setback measurement instructions. Front | 20 ft (3) | Nonresidential Ground Floor0-10 ft (min/max) | Nonresidential Ground Floor0-10 ft (min/max) | Nonresidential Ground Floor0-10 ft (min/max) | Nonresidential Ground Floor0-10 ft (min/max) | 7.5 ft adjacent to a residential zone or use; none required elsewhere Residential Ground Floor5-12 ft (min/max) | Residential Ground Floor5-12 ft (min/max) | Residential Ground Floor5-12 ft (min/max) | Residential Ground Floor5-12 ft (min/max) Side—Interior (each) | 5 ft adjacent to a residential zone or use; none required elsewhere. | 0 -10 ft (min/max); 5 ft required when directly abutting existing low-density residential development. | 0 -10 ft (min/max); 5 ft required when directly abutting existing low-density residential development. | 0 -10 ft (min/max); 5 ft required when directly abutting existing low-density residential development. | 0 -10 ft (min/max); 5 ft required when directly abutting existing low-density residential development. | 5 ft adjacent to a residential zone or use; none required elsewhere. Side—Corner | Same as interior side | 0-10 ft (min/max) | 0-10 ft (min/max) | 0-10 ft (min/max) | 0-10 ft (min/max) | Same as interior side Rear | 20 ft | 5 ft adjacent to a low-density or medium low-density residential zone or use; none required elsewhere. | 5 ft adjacent to a low-density or medium low-density residential zone or use; none required elsewhere. | 5 ft adjacent to a low-density or medium low-density residential zone or use; none required elsewhere. | 0 ft; 5 feet required when directly abutting existing low-density residential development | 5 ft adjacent to a residential zone or use; none required elsewhere. Lot coverage (1) | Maximum percentage of total lot area that may be covered by structures. Maximum coverage | 85% | 100% | 100% | 100% | 100% | 100% Height limit | Maximum allowable height of structures. See Section 20-30.070 (Height Limits and Exceptions) for height measurement requirements, and height limit exceptions. Maximum height | 55 ft | See FAR Section 20-23.060. For properties without an assigned FAR, a max of 35 ft | See FAR Section 20-23.060. | See FAR Section 20-23.060. | See FAR Section 20-23.060. | 55 ft Landscaping | See Chapter 20-34 (Landscaping Standards) Parking | See Chapter 20-36 (Parking and Loading) Signs | See Chapter 20-38 (Signs) Notes: (1) | Subdivision or Conditional Use Permit approval may establish specific requirements for minimum lot area, maximum lot coverage, setbacks, and/or dimensions based on the characteristics of the site or surroundings, environmental constraints, and/or other issues. (2) | The Design Review process may require larger setbacks. (3) | A 20-foot front setback is required for buildings and off-street parking areas; outdoor auto display areas require no front setback. (4) | See Zoning Code Section 20-23.060 for additional zoning district development standards. TABLE 2-9—TV-M DISTRICT DEVELOPMENT STANDARDS Development Feature | Requirement by Zoning District TV-M Minimum lot size | Minimum area and dimensions for parcels proposed in new subdivisions. Area (1) | None required (1) Dimensions (1) | None required (1) Residential density | Maximum number of dwelling units allowed on a parcel. The actual number of units will be determined by the City through subdivision or land use permit approval. Maximum density | 40 units per acre minimum Setbacks (1) (2) | Minimum setbacks required. See Section 20-30.110 for setback measurement instructions. Front | None, except as required by the review authority (3) Side—Interior (each) Side—Corner | None, except as required by the review authority (3) Rear | None, except as required by the review authority (3) Lot coverage (1) | Maximum percentage of total lot area that may be covered by structures. Maximum coverage | 100% Height limit | Maximum allowable height of structures. See Section 20-30.070 (Height Limits and Exceptions) for height measurement requirements, and height limit exceptions. Maximum height | 7 stories for properties south of 3rd Street5 stories for properties north of 3rd Street (4)All new development must be a minimum of 2 stories. Landscaping | See Chapter 20-34 (Landscaping Standards) Parking | See Chapter 20-36 (Parking and Loading) Signs | See Chapter 20-38 (Signs) Notes: (1) | Subdivision or Conditional Use Permit approval may establish specific requirements for minimum lot area, maximum lot coverage, set backs, and/or dimensions based on the characteristics of the site or surroundings, environmental constraints, and/or other issues. (2) | The Design Review process may require larger setbacks. (3) | The Station Area Streets Combining District may require special setbacks. (4) | All projects north of 3rd Street that are over 35 feet tall or two stories are subject to review and approval by the Cultural Heritage Board and Design Review Board per requirements of the –H Combining District.

( Ord. 3677 § 1, 2004 ; Ord. 3711 § 1 Exh. A, 2005 ; Ord. 3799 § 1, 2006 ; Ord. 3810 § 1, 2007 ; Ord. 3950 § 10, 2010 ; Ord. 2020-014 § 11 ; Ord. 2025-014 , 11/18/2025 )

Ask a question about Santa Rosa law

Corpus searches the Santa Rosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.