For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 20-23.060 — CMU, SMU, MMU, NMU zoning district development standards

Code of Ordinances, City of Santa Rosa, California (Code 2026-09-15: eCode360 publication current through Ord. No. 2026-014 adopted September 15, 2026 (scraped 2026-11-20)) · Santa Rosa Code of Ordinances § 20-23.060

Corpus is an independent public-information project, not the official City of Santa Rosa website. Stable reference: corpuslaw.us/code/3b7b67bb-ad8d-41fc-8737-f37707bbdd6d

§ 20-23.060: CMU, SMU, MMU, NMU zoning district development standards.

The standards of this section are intended to support a mixed use and pedestrian-oriented Downtown. Development within the CMU, SMU, MMU, NMU zoning districts shall comply with the following standards and any other applicable requirements of this Chapter and Zoning Code. See also the General Plan and Section 2 – Core Area of the City's Design Guidelines. A. Floor area ratio (FAR). 1. The following map shows the maximum base FAR allowed within specified areas of the CMU, SMU, MMU, and NMU zoning districts. a. 12 historic properties within the CMU zoning district have no assigned FAR (eastside of B Street between 7th Street and Lincoln Street, and one property on 10th Street as shown in Figure 2-1.A). See Table 2-8 for height and density development standards. [image] Figure 2-1.A 2. Calculations. FAR is a ratio of the building(s) total floor area divided by gross lot area as follows: a. Building total floor area is the entire area within the walls of a building, measured in a horizontal plane from the outside edge of exterior wall to exterior wall or from the center line of common walls to the outside edge of exterior walls, in square feet. For FAR calculation, total floor area excludes: • | Crawl spaces. • | Structured parking and carports. • | Breezeways. • | Attics without floors. • | Porches, balconies, and terraces. • | Below-grade structures. • | Outdoor recreational spaces (common, public, or private). • | The area of any designated historic structure to be preserved on a specific site, so long as the historic and/or architectural character of the structure is rehabilitated and not adversely affected. • | Active ground floor uses in areas where active ground floor requirements apply in the AGF combining district. b. For an interior building space where the ceiling height exceeds 20 feet above floor height, the floor area square footage is doubled for the purpose of calculating FAR. This is to ensure that double-height lobbies, ballrooms, and similar spaces are adequately accounted for in the FAR calculation. c. Gross lot area is the total area included within the lot lines of a lot, exclusive of adjacent dedicated street rights-of-way. 3. New development is required to achieve the mid-point or higher of the maximum FAR. Exceptions are allowed where parcel configuration, historic preservation, or utility constraints make the mid-point impossible to achieve. B. Site design and building placement. 1. All development is subject to sight distance and vision triangle requirements contained in Section 20-30.110. 2. Setbacks. Building placement shall comply with the respective zoning district standards shown in Section 20-22.050 Table 2-5, or Section 20-23.040 Table2-8. 3. Buildings shall be constructed at the required front setback for at least 70 percent of linear street frontage. This build-to-line requirement may be modified or waived if elements such as entry courtyards, plazas, entries, outdoor eating and display areas, or mature heritage trees, are located between the build-to line and building, provided that the buildings are built to the edge of the courtyard, plaza, dining, or landscaped area. 4. Development on lots over 60,000 square feet in size shall comply with tower separation requirements shown on Figure 2-1.B. Residential towers over 100 feet tall shall be separated from other towers by a minimum of 100 feet as measured from the closest point of the face of one tower to the next, while nonresidential towers over 100 feet tall shall be separated by a minimum of 80 feet, measured similarly. [image] Figure 2-1.B 5. For portions of buildings above 100 feet, as shown in Figure 2-1.B, the dimension of the longest building side and the diagonal shall not exceed the following: • | Commercial uses. Maximum side: 200 feet; maximum diagonal: 220 feet; • | Residential uses. Maximum side: 140 feet; maximum diagonal: 160 feet. 6. Development on First Street or Third Street between A Street and D Street in the Core Area shall not cast shadows covering more than 25 percent of Courthouse Square for more than three hours between the hours of 9:00 a.m. and 3:00 p.m. Pacific Standard Time (between late October and early April), or for more than four hours between 9:00 a.m. and 5:00 p.m. Pacific Daylight Time (between early April and late October). See Shadow Study, Figure 2-1.C. [image] Figure 2-1.C C. Building design. 1. Dimensional relief. Building design shall create visual interest and avoid large-scale, bulky, or box-like appearance (see Figure 2-1.D). Design alternatives include, but are not limited to: a. Wall plane variety; b. Height or roof form variety; and c. Incorporation of architectural detail or vegetative elements into façade design. [image] Figure 2-1.D 2. Design extent. Façade architectural articulation and finishes shall be consistently applied to all sides of the structure. 3. Transparency (fenestration) requirements. Primary and side street non-residential building facades shall incorporate ground floor transparency/fenestration for 60 percent of the main frontage and 25 percent of the side façade, or as allowed by local building code. 4. Ground level design requirements. a. Ceiling height. The minimum floor-to-ceiling height of the ground floor commercial space shall be at least 12 feet, as shown in Figure 2-1.E. [image] Figure 2-1.E b. Primary building entrance. A primary building entrance may be individual or shared. The entrance shall be prominent and easy to identify; shall face a public street or paseo; and shall incorporate a projection (porch, stoop, bay window, etc.), recess, or a combination of porch or recess. c. Architectural features. Ground-level architectural features such as porches and stoops may project up to six feet into the required setbacks. Architectural features such as balconies, bay windows, and awnings may project up to six feet over the property line, if located at least 10 feet above sidewalk grade. d. The depth of ground floor commercial space shall be sufficient to encourage small scale, or larger, commercial retail tenancies. Smaller tenant spaces, including pop-up stores and mini-shops, may be approved in certain locations, such as on side streets or garage frontages. e. No street-facing walls may run in a continuous plane for more than 20 feet without an opening. Openings fulfilling this requirement shall have transparent glazing and provide views into work areas, display areas, sales areas, lobbies, or similar active spaces, or into window displays that are at least three feet deep. The maximum length of the blank wall may be 30 feet for retail establishments with a gross floor area of 25,000 square feet or greater, as shown in Figure 2-1.F. [image] Figure 2-1.F f. Franchise architecture that is generic in nature, intended to be repeated on a mass-scale throughout a large region without consideration of and adaptation to local visual or cultural context, is prohibited unless doing so would violate State or Federal law.

( Ord. 2020-014 § 12 ; Ord. 2021-012 § 14 )

Ask a question about Santa Rosa law

Corpus searches the Santa Rosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.