§ 131.0713
Building Frontage Activation, Articulation and Transparency
San Diego Municipal Code Chapter 13 (Zones) · San Diego Municipal Code § 131.0713
Corpus is an independent public-information project, not the official City of San Diego website. Stable reference URL
The purpose and intent of these regulations is to create visual interest that enhances the pedestrian experience, assists in diminishing the overall mass of buildings, and creates variation from a pedestrian’s perspective. (a) All buildings shall be oriented so that primary pedestrian entrances for each ground floor use are accessible from an abutting public sidewalk or pedestrian connection to a sidewalk. Where there is an internal pedestrian pathway or a plaza, the primary pedestrian entrance may be internal. (b) All buildings located on a public right-of-way and building facades that front a private drive, plaza, or other open space area in the development shall provide a minimum of two frontage activation elements from Table 131-07C. Chapter 13: Zones (3-2026) 20 Table 131-07C Building Frontage Activation Elements Activation Element Amount- Minimums Min Width Min Depth Commercial Storefront None None None Porches, Patios, Yards and/or Stoops 50% of the building facade at ground level or one for every 30 feet of frontage At least 30 square feet in total area None None Vertical and/or Horizontal Off- Setting Planes None 2 ft 2 ft Balconies 30% of the building facade or one for every 30 feet of frontage 4 ft 6 ft Arcades, Colonnades or Galleries 30% of the building facade 20 ft 10 ft Awning, Canopy, Marquee, Sunshade or Trellis 50% of the building facade at ground level 15% for upper floor building facades 2 ft 2 ft Roll up or Large Opening Doors None, but still subject to transparency requirements Greater than 5 ft N/A Plazas See Section 131.0718(d)(7) 20 ft N/A Paseos None 8 ft N/A (c) The maximum length for the portion of a building located within 20 feet of a street property line is 100 feet, unless there is a recess or separation to break up the building mass. 21 Chapter 13: Zones (3-2026) (d) A total of 50 percent of the building facade shall be offset by at least two feet in depth from the rest of the building facade. (e) For buildings exceeding eight dwelling units, at least 30 percent of the roof area shall have designs that vary and provide either vertical or horizontal relief from the remainder of the roof area. (f) Buildings at intersections with traffic signals shall include one of the following gateway or architectural features at the corner. These features may not exceed the height limit within the Coastal Overlay Zone or other height overlay zones. (1) Rounded corner with vertical or horizontal projecting or exaggerated roof element; (2) Corner plaza; (3) Recessed entries; (4) Variations in materials or color; or (5) Roll up or large opening doors greater than five feet in width. (g) For non-residential uses, a minimum of 60 percent of the street wall area on the ground floor shall be transparent. (h) For residential uses, a minimum of 40 percent of street wall area on the ground floor shall be transparent. Chapter 13: Zones (3-2026) 22 Diagram 131-07A Transparency Requirement for Non-Residential Uses (“Building Frontage Activation, Articulation and Transparency” added 9-12-2019 by O-21118 N.S.; effective 10-12-2019.) 23 Chapter 13: Zones (3-2026)