For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.38.040 — Multi-Unit Dwellings

Stockton Municipal Code, California (Code 2026-10-13: eCode360 publication current through the 2026-10-13 codification (scraped 2026-11-17)) · Stockton Municipal Code § 16.38.040

Corpus is an independent public-information project, not the official City of Stockton website. Stable reference: corpuslaw.us/code/42ad658e-9beb-4b6e-b912-25388811276d

§ 16.38.040: Multi-Unit Dwellings.

A. Applicability. Development with two or more dwelling units in a single building (including, but not limited to, duplexes, triplexes, fourplexes, townhouses, and apartment buildings) shall meet the design standards of this section. B. Building Orientation. Buildings located along a street or pedestrian walkway shall be oriented toward the adjacent street or pedestrian walkway with the building frontage parallel to the fronting street or pedestrian walkway, except as follows: 1. Where lots have frontage on two or more streets, buildings shall be oriented to at least one street. 2. Where lots front only onto an arterial or collector street, buildings may be oriented toward an interior drive or walkway. 3. Waivers. Should the applicant elect not to meet the above objective building orientation standards, the applicant may request a waiver pursuant to Chapter 16.176 (Waivers). A waiver of the building orientation requirements may be approved upon finding that orienting the buildings to the street or pedestrian walkway is incompatible design, context, and/or use and street-facing building walls exhibit architectural relief and detail, and are enhanced with landscaping to create visual interest at the pedestrian level. C. Entrances. Entrances to dwelling units shall be designed as individual or shared entrances at the ground floor of the building. 1. Shared Entrances. All buildings with any exterior entrance that provides access to more than one unit shall provide a minimum of one principal shared entranceway per building in accordance with the following standards. a. Buildings located along a street shall provide a principal entrance facing and visible to the street, and connected directly to a public sidewalk via a private pedestrian walkway, except as follows: i. Where lots have frontage on two or more streets, buildings must have a principal entry on at least one street. ii. Where lots front only onto an arterial or collector street, the principal entrance may be oriented toward the interior of the lot. b. Principal entrances located in the interior of a site shall be accessed from a pedestrian walkway that is a minimum of four feet wide and connects to a public walkway. c. The principal entrance shall lead to a common area a minimum of 10 feet in each dimension. d. The principal entrance shall be emphasized utilizing at least one of the following methods: i. A roofed projection over the door (such as an awning, canopy, or overhang) with a minimum depth of five feet and a minimum horizontal area of 30 square feet. ii. A recessed entry bay with a minimum width of 15 feet and a minimum depth of five feet. iii. A landing, deck, or stoop with a minimum six-foot by six-foot area. [image] FIGURE 3-10A MULTI-UNIT DWELLINGS, SHARED ENTRANCE DESIGN 2. Individual Entrances. All units accessed through ground level individual entrances from the exterior shall provide a minimum of one principal individual entrance per unit that creates both a presence on the street and establishes a clear separation between the public and private realms in accordance with the following standards. a. All individually accessed units located along a street or pedestrian walkway shall have a principal entrance oriented to and facing a street or pedestrian walkway, except as follows: i. Where lots have frontage on two or more streets, units must have a principal entrance on at least one street. ii. Where lots front only onto an arterial or collector street, the principal entrance may be oriented toward the interior of the lot. b. All principal entrances located in the interior of a site shall be accessed from a pedestrian walkway that is a minimum of four feet wide and connects to a public sidewalk. c. The principal entrance shall be emphasized using at least one of the following methods: i. A projection such as a canopy or overhang with a minimum depth of three feet. ii. A recess a with a minimum depth of three feet and a minimum width of three feet. iii. A landing, deck, or stoop with a minimum four-foot by four-foot area. d. Any individual entrance located within 10 feet of a front or street-side property line shall be raised a minimum of 18 inches above grade. [image] FIGURE 3-10B MULTI-UNIT DWELLINGS, INDIVIDUAL ENTRANCE DESIGN 3. Waivers. Should the applicant elect not to meet the above objective entrance standards, the applicant may request a waiver pursuant to Chapter 16.176 (Waivers). A waiver of the entrance requirements may be approved upon finding that, the project includes features that create a welcoming feeling toward the street, such as a trellis, landscaped courtyard entry, enhanced walkway, columns or other architectural features. D. Building Design. Buildings shall include the following design features to create visual variety and avoid a large-scale and bulky appearance. 1. Massing Increment. For building facades 150 feet or longer, a change in facade plane with a recess a minimum of 15 feet wide and 10 feet deep shall be provided for every 150 feet of building frontage. [image] FIGURE 3-10C MULTI-UNIT DWELLINGS, MASSING INCREMENT 2. Roof Line. Roof lines shall be varied and designed to minimize the bulk of a building, screen roof-mounted equipment, and enhance the building's architectural design through the following methods: a. A minimum of one roof line offset of at least 18 inches in height and 15 feet in length shall be provided for every 150 feet of facade length. b. Where parapets are provided, the minimum 18-inch offset in height required above may be substituted by an offset of at least 18 inches in depth. All parapets shall provide returns of at least six feet in depth at the end of the parapet face to avoid a false front appearance. [image] FIGURE 3-10D MULTI-UNIT DWELLINGS, ROOF LINE 3. Vertical Articulation. In buildings of two or more stories, upper and lower stories shall be distinguished by incorporating one or more of the following features. These features may be applied to the transitions between any floors, except where otherwise specified. a. A change in facade materials, along with a change in plane at least four inches in depth at the transition between the two materials. b. A horizontal design feature such as an awning, overhang, cornice line, water table, or belt course. c. A base treatment a minimum of four feet at the ground floor consisting of a material such as stone, concrete masonry, or other material distinct from the remainder of the facade and projecting at least two inches from the wall surface of the remainder of the building. d. Setting back the top floor or floors of the building at least five feet from the remainder of the facade. [image] FIGURE 3-10E MULTI-UNIT DWELLINGS, VERTICAL ARTICULATION 4. Townhomes and Rowhouses. In addition to the other building design requirements of this Section, attached side-by-side dwelling units shall meet the following requirements. a. Unit Articulation. Individual units shall be emphasized through two or more of the following methods. The methods chosen to meet this requirement may count toward other design requirements provided the necessary criteria are met. i. Variations of two feet or more between the horizontal planes of the primary entrance facade of adjacent units. ii. A change in roof orientation between adjacent units (e.g., a gable roof adjacent to a hipped roof). iii. A roofline offset of at least 18 inches for each unit exposed on the associated elevation. iv. Change of colors or materials. [image] FIGURE 3-10F TOWNHOMES AND ROWHOUSES, UNIT ARTICULATION 5. Waivers. Should the applicant elect not to meet the objective building design standards, the applicant may request a waiver pursuant to Chapter 16.176 (Waivers). A waiver of the building design requirements may be approved upon finding that adequate design features have been incorporated to create visual variety and avoid a large-scale and bulky appearance. E. Window and Garage Door Trim or Recess. Windows and garage doors shall have trim at least three inches wide and one-half inch in depth, or be recessed at least two inches from the plane of the surrounding exterior wall. Should the applicant elect not to meet the objective window and garage trim or recess requirement, the applicant may request a waiver pursuant to Chapter 16.176 (Waivers). A waiver of the window and garage trim or recess requirement may be approved upon finding that providing the required window or garage trim or recess would be inconsistent with the architectural style of the structure and alternative methods have been incorporated to create shadow and depth along the facade. [image] FIGURE 3-10G MULTI-UNIT DWELLINGS, WINDOW AND GARAGE DOOR TRIM OR RECESS F. Street Frontage Transparency. Exterior walls facing a street shall include windows or doors, inclusive of inset frames, for at least 25% of the ground floor building wall. No wall shall run in a continuous plane of more than 30 feet without a window, door, or other opening. 1. Waivers. Should the applicant elect not to meet the above objective residential street frontage transparency standard, the applicant may request a waiver pursuant to Chapter 16.176 (Waivers). A waiver of the residential street frontage transparency requirement may be approved upon finding that: a. The proposed project or its location has certain characteristics with which providing the required windows and openings is incompatible; and b. Street-facing building walls exhibit architectural relief and detail, and are enhanced with landscaping to create visual interest at the pedestrian level. G. Underground and Tuck Under Parking. The maximum above ground height of an underground or tuck under parking area within 20 feet of the primary street facing property line shall be three feet from finished grade. [image] FIGURE 3-10H UNDERGROUND AND TUCK UNDER PARKING, MAXIMUM ABOVE GROUND HEIGHT

( Ord. 2025-06-03-1601 , 6/3/2025 )

Ask a question about Stockton law

Corpus searches the Stockton sections it holds and shows the ones that match, with their citations. Free, no sign-in.