For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.38.050 — Mixed-use buildings

Stockton Municipal Code, California (Code 2026-10-13: eCode360 publication current through the 2026-10-13 codification (scraped 2026-11-17)) · Stockton Municipal Code § 16.38.050

Corpus is an independent public-information project, not the official City of Stockton website. Stable reference: corpuslaw.us/code/71e1fc8a-7b8e-4c87-860f-a6bb8350c1e7

§ 16.38.050: Mixed-use buildings.

A. Applicability. Buildings containing residential and nonresidential uses as primary uses in a single building, including live-work units, shall meet the design standards of this section. B. Building Orientation. Buildings located along a street or pedestrian walkway shall be oriented toward the adjacent street or pedestrian walkway with the building frontage parallel to the fronting street or pedestrian walkway, except as follows: 1. Where lots have frontage on two or more streets, buildings shall be oriented to at least one street. 2. Where lots front only onto an arterial street, buildings may be oriented toward an interior drive or walkway. 3. Waivers. Should the applicant elect not to meet the above objective building orientation standards, the applicant may request a waiver pursuant to Chapter 16.176 (Waivers). A waiver of the building orientation requirements may be approved upon finding that the design, context, and/or use of the project make orienting the buildings to the street or pedestrian walkway incompatible and the project includes designs that create a welcoming feeling toward the street, such as incorporating features such as a trellis, landscaped courtyard entry, enhanced walkway, columns or other architectural features. C. Entrances. 1. Ground Floor Residential Uses. Ground floor residential units shall meet the entrance requirements of Section 16.38.040.C (Entrances), above. 2. Ground Floor Nonresidential Uses. There shall be a minimum of one principal entrance for every 50 feet of building frontage with a maximum separation of 100 feet between entrances. Principal entrances shall be designed in accordance with the following standards. a. In buildings located within 30 feet of a street-facing property line, the principal building entrance shall face the street. Alternatively, the principal building entrance may face perpendicular to the street, provided it is within 10 feet of the street-facing property line. [image] FIGURE 3-11A GROUND FLOOR NONRESIDENTIAL USES, ENTRANCE DESIGN b. Buildings located at corners shall provide a principal entrance toward each street or have a corner entrance that provides a common entrance to the building from both streets. [image] FIGURE 3-11B GROUND FLOOR NONRESIDENTIAL USES, CORNER BUILDINGS ENTRANCE DESIGN 3. Waivers. Should the applicant elect not to meet the above objective entrance standards, the applicant may request a waiver pursuant to Chapter 16.176 (Waivers). A waiver of the entrance requirements may be approved upon finding that the design, context, and/or use of the project make the entrance requirements incompatible and that street-facing building walls incorporate architectural features, exhibit relief and detail, and are enhanced with landscaping to create visual interest at the pedestrian level. D. Building Design. Buildings shall include the following design features to create visual variety and avoid a large-scale and bulky appearance. 1. Massing Increment. For building facades 150 feet or longer, a change in facade plane with a recess a minimum of 15 feet wide and 10 feet deep shall be provided for every 150 feet of building frontage. [image] FIGURE 3-11C MIXED USE BUILDINGS, MASSING INCREMENT 2. Roof Line. Roof lines shall be varied and designed to minimize the bulk of a building, screen roof-mounted equipment, and enhance the building's architectural design through the following methods: a. A minimum of one roof line offset of at least 18 inches in height and 15 feet in length shall be provided for every 150 feet of facade length. b. Where parapets are provided, the minimum 18-inch offset in height required above may be substituted by an offset of at least 18 inches in depth. All parapets shall provide returns of at least six feet in depth at the end of the parapet face to avoid a false front appearance. [image] FIGURE 3-11D MIXED USE BUILDINGS, ROOF LINE 3. Vertical Articulation. In buildings of two or more stories, upper and lower stories shall be distinguished by incorporating one or more of the following features. These features may be applied to the transitions between any floors, except where otherwise specified. a. A change in facade materials, along with a change in plane at least one inch in depth at the transition between the two materials. b. A horizontal design feature such as an awning, overhang, cornice line, water table, or belt course. c. A base treatment a minimum of four feet at the ground floor consisting of a material such as stone, concrete masonry, or other material distinct from the remainder of the facade and projecting at least two inches from the wall surface of the remainder of the building. d. Setting back the top floor or floors of the building at least five feet from the remainder of the façade. [image] FIGURE 3-11E MIXED USE BUILDINGS, VERTICAL ARTICULATION 4. Waivers. Should the applicant elect not to meet the objective building design standards, the applicant may request a waiver pursuant to Chapter 16.176 (Waivers). A waiver of the building design requirements may be approved upon finding that adequate design features have been incorporated to create visual variety and avoid a large-scale and bulky appearance. E. Windows and Openings. 1. Nonresidential Uses: Building Transparency/Required Openings. Exterior walls facing a street or pedestrian walkway shall include windows, doors, or other openings for at least 50% of the building wall area located between 2 1/2 and seven feet above the level of the sidewalk. a. Design of Required Openings. Openings fulfilling this requirement shall have transparent glazing and provide views into work areas, display areas, sales areas, lobbies, or similar active spaces, or into window displays that are at least three feet deep. b. Waivers. Should the applicant elect not to meet the above objective building transparency/required openings standards, the applicant may request a waiver pursuant to Chapter 16.176 (Waivers). A waiver of the building transparency/required openings requirements may be approved upon finding that: i. The proposed use has certain operational characteristics with which providing the required windows and openings is incompatible; and ii. Street-facing building walls exhibit architectural relief and detail, and are enhanced with landscaping to create visual interest at the pedestrian level. [image] FIGURE 3-11F MIXED USE BUILDINGS, NONRESIDENTIAL USES: BUILDING TRANSPARENCY/REQUIRED OPENINGS 2. Residential Uses: Window Trim or Recess. Windows for residential uses shall have trim at least three inches wide and one-half inch in depth, or be recessed at least two inches from the plane of the surrounding exterior wall. Should the applicant elect not to meet the objective window trim or recess requirement, the applicant may request a waiver pursuant to Chapter 16.176 (Waivers). A waiver of the window trim or recess requirement may be approved upon finding that providing the required window trim or recess would be inconsistent with the architectural style of the structure and alternative methods have been incorporated to create shadow and depth along the facade. [image] FIGURE 3-11G MIXED USE BUILDINGS, RESIDENTIAL USES: WINDOW TRIM OR RECESS F. Underground and Tuck Under Parking. The maximum above ground height of an underground or tuck under parking area within 20 feet of the primary street facing property line shall be three feet from finished grade. [image] FIGURE 3-11H UNDERGROUND AND TUCK UNDER PARKING, MAXIMUM ABOVE GROUND HEIGHT

( Ord. 2025-06-03-1601 , 6/3/2025 )

Ask a question about Stockton law

Corpus searches the Stockton sections it holds and shows the ones that match, with their citations. Free, no sign-in.