For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.54.040 — Design requirements

Code of Ordinances, City of Sunnyvale, California (includes legislation through Ord. No. 3260-26 adopted August 11, 2026) · Sunnyvale Code of Ordinances § 19.54.040

Corpus is an independent public-information project, not the official City of Sunnyvale website. Stable reference: corpuslaw.us/code/e2734ee5-8be9-467d-81e3-fa648377cbc0

§ 19.54.040: Design requirements.

In addition to all other requirements set forth in this chapter, all wireless telecommunication facilities shall meet the following design requirements: (a) Based on potential aesthetic impact, the order of preference for facility type is: façade mounted, roof mounted, ground mounted, and freestanding tower. If a ground mounted or freestanding tower is proposed, the application must include an explanation as to why other facility types are not being considered. (b) All facilities shall be designed to minimize the visual impact to the greatest extent feasible, considering technological requirements, by means of placement, screening, and camouflage, to be compatible with existing architectural elements and building materials, and other site characteristics. The applicant shall use the smallest and least visible antennas possible to accomplish the owner/operator's coverage objectives. (c) Colors and materials for facilities shall be chosen to minimize visibility. Facilities shall be painted or textured using colors to match or blend with the primary background. (d) Facility lighting shall be designed so as to meet but not exceed minimum requirements for security, safety or FAA regulations, and in all instances shall be designed so as to avoid glare and minimize illumination on adjacent properties. (e) Lightning arresters and beacon lights shall not be included in the design of facilities unless required by the FAA. Lightning arresters and beacons shall be included when calculating the height of facilities such as towers, lattice towers and monopoles. (f) Façade mounted equipment shall be camouflaged by incorporating the antenna into the dominant design elements of the building; they shall be painted and textured to match the existing structure, and shall not project beyond a maximum of eighteen inches from the face of the building or other support structure unless allowed by a minor use permit. (g) Satellite dish or parabolic antennas shall be situated as close to the ground as possible to reduce visual impact without compromising their function. No such antenna shall be located in any front yard, nor in a corner side yard unless the antenna is screened from pedestrian-level view. No such antenna exceeding thirty-nine inches in diameter shall be located within a required setback unless approved through a miscellaneous plan permit upon a showing that no reasonable alternative location is available. (h) All facilities shall be designed so as to be resistant to and minimize opportunities for unauthorized access, climb-ing, vandalism, graffiti, and other conditions which would result in hazardous conditions, visual blight, or attractive nuisances. (i) Where appropriate, facilities shall be installed so as to maintain and enhance existing landscaping on the site, including trees, foliage and shrubs, whether or not utilized for screening. Additional landscaping shall be planted where such vegetation is deemed necessary to provide screening or to minimize the visual impact of the facility. (j) All monopoles and lattice towers shall be designed to be the minimum functional height and width required to support the proposed antenna installation. (k) Roof mounted antennas shall be constructed at the minimum height possible to serve the operator's service area. Roof mounted antennas shall be designed to minimize their visibility. (l) In order of preference, ancillary support equipment for facilities shall be located either within a building, in a rear yard or on a screened roof top area. Support equipment pads, cabinets, shelters and buildings require architectural, landscape, color, or other camouflage treatment for minimal visual impact. (m) No freestanding facility or ancillary support equipment may be located between the face of a building and a public street, bikeway or park, except for approved facade-mounted equipment or facilities located on existing or new permitted structures in accordance with this section. (n) The city shall retain the authority to limit the number of antennas with related equipment and providers to be located at any site and adjacent sites in order to prevent negative visual impact associated with multiple facilities. Architectural and other camouflaging treatment shall be coordinated between all users on each site. (o) Landscaping, including shrubs and trees shall be used, when possible, to block the line of sight between facilities and adjacent residential uses and residentially zoned properties. (p) Freestanding facilities, including towers, lattice towers, and monopoles, shall be restricted to a maximum height of sixty-five feet when located adjacent to residentially zoned properties. New facilities located on private property shall be set back at a ratio of two horizontal feet for every one foot in height. Facilities located on private property shall not be readily visible to the nearest residentially zoned property. (q) At the time of modification or upgrade of facilities, existing equipment shall be replaced with equipment of equal or greater technical capacity and reduced size so as to reduce visual impact. (r) Except as approved by use permit, no component of any facility shall be located within required front or side yard setbacks, except for facilities mounted on poles in the public right-of-way, or facilities and related equipment not readily visible mounted on existing or new structures already allowed by the Municipal Code. No facility component shall be located so that it straddles a property line. (s) Proposed facilities shall not reduce below the amount required the number of available parking spaces.

( Prior zoning code § 19.70.050 ; Ord. 2623-99 § 1 ; Ord. 3031-13 § 2 )

Ask a question about Sunnyvale law

Corpus searches the Sunnyvale sections it holds and shows the ones that match, with their citations. Free, no sign-in.