§ 15.04.020 — California Building Code

Municipal Code, City of Temecula, California (legislation through Ord. No. 2026-04 adopted April 14, 2026) · Temecula Municipal Code § 15.04.020

Corpus is an independent public-information project, not the official City of Temecula website. Stable reference: corpuslaw.us/code/9c05160b-67c5-4008-a769-da695517cba1

§ 15.04.020: California Building Code.

The following amendments, additions and deletions are made to the California Building Code, 2025 Edition, as adopted by this chapter. A. Section 105.2 is hereby amended by modifying subsection 4 under Building, to read as follows: 4. Retaining walls that are not over three (3) feet in height unless supporting a sloped surcharge and garden walls not over four (4) feet in height, measured from the top of footing to top of wall or impounding flammable Class I, Class II or III-A liquids. B. Section 105.3 is hereby amended by adding subsection 8 to read as follows: 8. All contractors and their subcontractors must have current and valid city business licenses. C. Section 105.5 is amended to read as follows: 105.5 Expiration: Every permit issued by the building official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 12 months or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days or if the permit is revoked. Before such work can be recommenced a new permit shall first be obtained by reinstatement of the permit and the fee therefor shall be one half the amount required for reinstating the permit for such work. A permittee may request an extension of a permit. The Building Official may grant in writing, one or more extensions of time for periods of not more than 180 days per extension. The permittee shall request an extension pursuant to this subdivision in writing and demonstrate justifiable cause for the extension. D. Section 110.3.8 is amended to read as follows: 110.3.8 Fire- and smoke-resistant penetrations. Protection of joints and penetrations in fire resistance-rated assemblies shall not be concealed from view until inspected for all designed fire protection. Required fire seals/fire barriers in fire assemblies at fire-resistant penetrations shall be installed and certified by a third party, state of California licensed fireproofing company and certification of compliance shall be provided for building official's final approval. E. Section 111.1 is hereby amended by adding the following: To ensure appropriate continued use of any occupied space the building official will issue a new Certificate of Occupancy upon any change of tenant at the fee rates established by resolution of the City Council. F. Section 114.4.1 is hereby added to read as follows: 114.4.1 Civil penalty. Any person, firm or corporation who shall proceed with or commence work for which a permit is required by these building and construction regulations without first having obtained such permit shall, if subsequently permitted to obtain a permit therefor, pay double the fee fixed for such work. The original permit fee shall be for issuance of the permit and the balance shall be a civil penalty. This provision shall not apply to emergency work when it shall be proved to the satisfaction of the building official that such work was urgently necessary and that it was not practical to obtain a permit before commencement of the work. In all such cases a permit must be secured as soon as it is practicable to do so, and if there is an unreasonable delay in securing the required permit, the civil penalty as provided in this section shall be charged. In no event shall such civil penalty exceed the permit fee plus five hundred dollars. The civil penalty provided in this section shall be in addition to any other fines and remedies prescribed elsewhere in this code. The payment of such fees and fine shall not relieve any person from fully complying with the requirements of these building and construction regulations in the execution of the work. G. Section 502.1 is amended to read as follows: 502.1 Address identification. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Where required by the fire code official, address numbers shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Commercial, multi-family residential and industrial buildings shall have a minimum of twelve (12) inch numbers with suite numbers being a minimum of six (6) inches in size. All suites shall have a minimum of six (6) inch high letters and/or numbers on both the front and rear doors. Single-family residences and multi-family residential units shall have four (4) inch letters and/or numbers, as approved by the Fire Prevention Bureau. Address numbers shall be maintained and illuminated. Exception: Building address numbers within the Downtown Core District (DTC) of the Old Town Specific Plan, are permitted to be a minimum of eight (8) inches in size. H. Section 901.2.1 is added to read as follows: 901.2.1 As-built/Revised documents. An electronic copy of as-built/revised drawings shall be submitted to the fire department online for approval prior to final of any permits. Redlines are not considered as-builts/revised plans. I. Section 903.2 is deleted in its entirety and replaced with the following: 903.2 Where required. 1. In all new buildings and structures which are 3,600 square feet or greater, an approved automatic sprinkler system shall be provided regardless of occupancy classification. Where the Sections 903.2.1 — 903.2.21 of the California Fire Code require more restrictive requirements than those listed below, the more restrictive requirement shall take precedence. 2. All existing buildings, except for one- and two-family dwellings, shall be retrofitted with automatic fire sprinklers when a structure exceeds 3,600 square feet and changes are made to the building including any of the following: change of use/occupancy, removal of an existing fire wall as defined by the California Building Code, or additions of 50% or more are made to the original building area and the resulting square footage exceeds 5,000 square feet. 3. One- and two-family dwellings shall have an automatic fire sprinkler system regardless of square footage in accordance with the California Residential Code. Fire sprinkler systems shall be installed in mobile homes, manufactured homes and multifamily manufactured homes with two dwelling units in accordance with Title 25 of the California Code of Regulations. Exceptions: Unless required elsewhere in this code or the California Building Code, automatic fire sprinkler systems shall not be required for the following: 1. | Spaces or areas in telecommunications buildings used exclusively for telecommunications equipment, associated electrical power distribution equipment, batteries not required to have an automatic sprinkler system by Section 1207 for energy storage systems and standby engines, provided that those spaces or areas are equipped throughout with an automatic smoke detection system in accordance with Section 907.2 and are separated from the remainder of the building by not less than 1-hour fire barriers constructed in accordance with Section 707 of the California Building Code or not less than 2-hour horizontal assemblies constructed in accordance with Section 711 of the California Building Code, or both. 2. | Detached Group U occupancies used for agricultural purposes constructed in accordance with the California Building Code. 3. | Detached non-combustible equestrian arena shade canopies that are open on all sides and used for riding only - no commercial, assembly or storage uses. 4. | Non-combustible fueling station canopies not exceeding 10,000 square feet when separated from other buildings by a distance of not less than 50 feet. 5. | Detached fabric or non-combustible shade structures that are open on all sides and used to shade playground equipment, temporary storage of vehicles and dining areas with no cooking. 6. | Where determined by the Fire Chief that no major life safety hazard exists, and the fuel load does not pose a significant threat to firefighter safety or to other structures or property, automatic fire sprinklers may be exempted. The following exceptions in the California Fire Code shall not be allowed: a. | Exception in Section 903.2.3. b. | Exception in Section 903.2.11.3. J. Section 903.3.5.3 is added to read as follows: 903.3.5.3 Hydraulically calculated systems. The design of hydraulically calculated fire sprinkler systems shall not exceed 90% of the water supply capacity. K. Section 903.3.10 is deleted in its entirety and replaced with the following: 903.3.10 Floor control valves. Approved supervised indication control valves shall be provided at the point of connection to the riser in all buildings. Valve locations will be placed in the fire sprinkler riser room on each riser. L. Section 904.2.2.1 is added to read as follows: 904.2.2.1 Extinguishing system monitoring requirements. All automatic fire-extinguishing systems will be required to be monitored by a fire alarm monitoring system. If a fire alarm monitoring system is not present, one will be required to be installed to provide monitoring for the automatic fire-extinguishing system. Where a fire alarm signaling system, or a Dedicated Function Fire Alarm System is serving the occupancy where the extinguishing system is located, the actuation of the automatic fire-extinguishing system shall actuate the fire alarm signaling system in accordance with the requirements of NFPA 72. M. Sections 907.1.6, 907.1.7 and 907.1.8 are added to read as follows: 907.1.6 Fire alarm control panel (FACP). The main fire alarm control panel shall be located in the same room as, and sharing the same access as the fire sprinkler riser. The FACP shall have a minimum 36 inches of face clearance and 6 inches side clearance from any other wall or equipment. Based on our climatic weather conditions and the requirements set forth in any of the manufacture specifications and installation requirements for fire alarm electronic equipment/panels, this room may be required to be climate controlled 907.1.7 Notification appliance. New tenant spaces and new occupancy buildings shall require alarm notification appliances. For multi-tenant buildings, an alarm notification appliance shall be placed in each tenant suite. For existing buildings with new tenants an alarm notification appliance shall be required in each tenant space. For existing buildings that are not equipped with a fire alarm system or sprinkler monitoring system, new tenants or owners shall be required to install the appropriate type of fire alarm system. 907.1.8 Duct detectors. Duct detectors located in any buildings that have a fire alarm system shall be powered from the main building fire alarm power supply. N. Section 1505.1 is hereby amended to read as follows: 1505.1 General. Roof assemblies shall be divided into the classes defined in this section. Class A, B and C roof assemblies and roof coverings required to be listed by this section shall be tested in accordance with ASTM E108 or UL 790. In addition, fire-retardant wood roof coverings shall be tested in accordance with ASTM D2898. The minimum roof coverings installed on buildings shall comply with Table 105.1 base do the type of construction of the building. The roof covering or roofing assembly on any structure regulated by this Code within the Historical District Overlay, generally known as the Old Town Temecula Historical Preservation District, shall not be less than a Class C roofing assembly. O. Section 1907A.2.1 is added to read as follows: 1907A.2.1 Additional requirements. Slab dowels in all occupancies, slab connection from existing slabs to new construction shall be placed at a minimum twenty-four (24) inches on center with reinforcing steel of one-half inch minimum diameter, eight (18) inches in length. Embedment to existing shall be a minimum of six (6) inches. P. The following appendices are deleted in their entirety: Appendices A, B, D, G, H, I, J, K, L, M, N, O and P.

( Ord. 2025-14 , 11/18/2025 )

Ask a question about Temecula law

Corpus searches the Temecula sections it holds and shows the ones that match, with their citations. Free, no sign-in.