§ 815.1.030: Definitions.
Notwithstanding the applicable definitions, symbols, and notations in the Building Code, the following definitions shall apply for the purposes of this Chapter: a) BUILDING CODE Is the current Building Code of the City of Torrance. b) CRIPPLE WALL Is a wood-framed stud wall extending from the top of the foundation wall to the underside of the lowest floor framing. c) DESIGN CRITERIA Is a document that outlines the design professional’s alternative analysis or Retrofit approach and methodology to satisfy the design intent and performance objective of the Ordinance. This document is intended to be used when the code and seismic Ordinance language does not address the proposed analysis or Retrofit approach or methodology. d) GROUND FLOOR Is any floor within the wood-frame portion of a building whose elevation is immediately accessible from an adjacent grade by vehicles or pedestrians. The ground floor portion of the structure does not include any floor that is completely below adjacent grades. e) HISTORICAL BUILDING Is any building designated, or currently in the process of being designated, as a "qualified historical building" as defined in Part 8, Title 24 of the California Code of Regulations. f) OPEN-FRONT WALL LINE Is an exterior Wall Line, without vertical elements of the lateral forceresisting system, which requires tributary seismic forces to be resisted by diaphragm rotation or contains an excessive cantilever beyond parallel lines of shear walls. Diaphragms that cantilever more than 25 percent of the distance between lines of lateral force resisting elements from which the diaphragm cantilevers shall be considered excessive. Diaphragm cantilevers or exterior balconies of 6 feet or less in width shall not be considered excessive cantilevers. g) OWNER OR BUILDING OWNER Is the individual(s), agent, firm, corporation, or entity having legal possession, equitable interest in the property, or rights to sanction evaluation or Retrofit of a building. h) RETROFIT Is an improvement of the lateral force resisting system by alteration of existing structural elements or addition of new structural elements. i) Seismic Design Guidelines are framework guidelines developed by the Building Official which are intended to calibrate, delineate, and detail technical requirements to be used for the retrofitting of buildings subject to this Chapter. j) SOFT WALL LINE Is a deficiency in a Wall Line in which the lateral stiffness is less than what is required by story drift limitations and deformation compatibility requirements of this Chapter. In lieu of the engineering analysis required by this Chapter to determine whether a wall line’s lateral stiffness is less than the aforementioned story drift limitations and deformation compatibility requirements, a Soft Wall Line deficiency may be defined as a Wall Line in a Story where the wall stiffness is less than 70 percent of the stiffness of the exterior wall above for the direction under consideration. k) STORY Is as defined in the Building Code, but includes any basement or under-floor space of a building with Cripple Walls exceeding four feet in height. l) STORY STRENGTH Is the total strength of all seismic-resisting elements sharing the same Story shear in the direction under consideration. m) WALL LINE Is any length of a wall along a principal axis of the building used to provide resistance to lateral loads. n) WEAK WALL LINE Is a deficiency of a Wall Line at the Ground Floor in which the wall strength is less than 80 percent of the strength of the wall above in the direction under consideration or is an exterior wall where the majority of the Ground Floor or basement portion of the structure contains an open floor space and the Ground Floor Story Strength is less than 80 percent of the Story Strength above. o) SUBSTANTIAL EVIDENCE Means more than a mere scintilla of evidence. Specifically, that there is such relevant evidence that a reasonable mind would accept it is adequate to support a conclusion, considering the totality of the evidence as a whole. p) GOOD CAUSE Means adequate or substantial grounds or reason to take certain action, or fail to take certain action required by this Chapter. (For example, the inability to secure funding for seismic retrofit repairs within the required time period, despite substantial evidence that a building owner has made best efforts to do so; or the inability to secure a contractor to perform seismic retrofit repairs within the required time period, despite substantial evidence that a building owner has made best efforts to do so, or other similar circumstances.)
Ask a question about Torrance law
Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.