For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 815.1.090 — Engineering analysis and design

Municipal Code, City of Torrance, California · Torrance Municipal Code § 815.1.090

Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/b1f676d5-83ee-49bb-bd31-42908a1ac392

§ 815.1.090: Engineering analysis and design.

a) Scope of Analysis. This Chapter requires the alteration, repair, replacement or addition of structural elements and their connections to meet the strength and stiffness in conformance with the Building Code except as modified herein. The lateral-load-path analysis shall include the resisting elements and connections from the wood diaphragm immediately above any Soft, Weak or Open-Front Wall lines to and including the foundation. Stories above the Weak Wall Line shall be considered in the analysis but need not be modified. The Engineer shall investigate existing conditions as applicable for the required analysis, including performing initial material testing and verification of existing conditions. b) Design Base Shear and Design Parameters. The design force in a given direction shall not be less than 75% of that derived from the Base Shear as determined from the seismic provisions of ASCE 7 and design provisions as specified by the current Seismic Design Guidelines. The structure shall be analyzed and/or strengthened in order to mitigate the Weak and/or Soft Wall Line deficiencies defined in Section 815.1.030. Exception: Alternatively, the structure may be retrofitted per Appendix A4 of the California Existing Building Code, provided the entire Story is analyzed and/or strengthened in order to mitigate the Weak and/or Soft Wall Line deficiencies defined in Section 815.1.030. c) Lateral Vertical Systems. Strengthening systems with concrete walls or masonry walls, or steel braced frames shall not be permitted unless a full building analysis considering diaphragm stiffness and torsional behavior is performed. d) Horizontal Structural Irregularities in Buildings with Three or More Stories. Structures with three or more stories having horizontal structural irregularities of either type 2, 3, 4, or 5 listed in ASCE 7, "Horizontal Structural Irregularities," shall be altered to meet the additional requirements of those sections referenced in the table for the Weak, Soft or Open-Front Wall lines being considered. e) Alternate Analysis, Base Shear and Design Parameters. The Building Official may approve alternate analysis and/or design methodologies that meet the same performance intent as those prescribed by this Chapter and that achieve the objectives established by this Chapter. A Design Criteria shall be submitted to the City for review and approval prior to submission of plans. Peer review shall be required when advanced systems, such as damped systems, are utilized. f) Additional Anchorage Requirements for Buildings on Hillsides. Where any portion of a building within the scope of this Chapter is constructed on or into a slope steeper than one-unit vertical in three units horizontal (33-percent slope), the lateral-force-resisting system, at and below the base level diaphragm, shall also be analyzed for the effects of concentrated lateral loads caused at the building base from the hillside conditions and comply with the provisions of the Building Code. g) Story Drift Limitations. The calculated story drift for each retrofitted Story shall meet the requirements of the current Seismic Design Guidelines. h) Deflection Compatibility. The design of the new retrofit elements shall be compatible with the existing structural elements. i) Ties, Continuity and Collectors. All parts of the structure included in the scope of analysis shall be interconnected and the connection shall be capable of resisting the seismic force created by the parts being connected as required per the Building Code. j) Foundations. Foundations shall be designed in accordance with the Seismic Design Guidelines. New foundation elements shall be capable of transferring the loads to the supporting soil without negatively impacting the existing foundations. k) Pole Foundations. The effects of rotation and soil stiffness shall be included in the analysis where lateral loads are resisted by vertical elements whose required depth of embedment is determined by pole formulas. The design of the pole foundations shall be based on an approved geotechnical investigation conducted in accordance with approved geotechnical engineering reports.

Ask a question about Torrance law

Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.